Curing-light attenuation in filled-resin restorative materials

被引:120
作者
Musanje, L.
Darvell, B. W.
机构
[1] Univ Hong Kong, Fac Dent, Prince Philip Dent Hosp, Hong Kong, Hong Kong, Peoples R China
[2] Oregon Hlth Sci Univ, Sch Dent, Dept Restorat Dent, Div Biomat & Biomech, Portland, OR 97239 USA
关键词
resin composite restorative materials; irradiance; light attenuation;
D O I
10.1016/j.dental.2005.11.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To characterize the attenuation of the curing light in filled resin restorative materials (FRRMs) to aid understanding of curing depth. Materials and methods. One hundred and eighty materials of various shades from several manufacturers were tested in various ways. One set (66 materials) was used to determine the applicability of Lambert's Law using a quartz - tungsten-halogen curing light (Optilux 400, Demetron Research) by measuring the transmitted light with a dental radiometer (Cure Rite, EFOS) for successive thicknesses of ground 10 mm diameter specimens from 3 to 0.5 mm in 0.5 mm steps. A second set (17 materials) were similarly tested with separate specimens from 1 to 5 mm in thickness using a transmission densitometer (DT1405, RY Parry) fitted with a curing-light dichroic filter. For a third (overlapping) set (165 materials), the 1 mm pure (reflectance-free) optical density (D-1 value) was determined from two specimens, similar to 1 and similar to 2 mm thick using the densitometer as above. From D, the critical thickness (x(CRIT)), identified as depth of cure (DoC) for an excess surface exposure factor of 2, was calculated. Results. Lambert's Law was found to hold with no evidence of appreciable differential absorption effects. Attenuation coefficient and D-1 were significantly correlated (P < 1 x 10(-13)). D-1 varied between about 0.23 and 0.72, for corresponding x(CRIT) values of 1.3 and 0.4 mm. There was no correlation between D-1 and reflectance (P > 0.09), and no systematic effect due to shade letter, but a highly significant (P < 7.5 x 10(-8)), but weak (-0.066 mm/unit), correlation between shade number and D1. Significance. Depth of cure can be calculated directly from the D, value determined via simple optical density measurements on two specimens providing that (a) an irradiation time can be determined for the surface of a specimen to be "sufficiently" cured (i.e. for DoC = 0 precisely), and (b) an excess internal surface exposure ratio can be chosen such that the corresponding DoC is attained in a practicable irradiation time. (C) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:804 / 817
页数:14
相关论文
共 37 条
[1]  
BURTSCHER P, 2005, J DENT RES A, V84, P1345
[2]   LIGHT-SCATTERING AND GLOSS OF AN EXPERIMENTAL QUARTZ-FILLED COMPOSITE [J].
CAMPBELL, PM ;
JOHNSTON, WM ;
OBRIEN, WJ .
JOURNAL OF DENTAL RESEARCH, 1986, 65 (06) :892-894
[3]  
CAUGHMAN WF, 1995, J AM DENT ASSOC, V126, P1280
[4]   The physical properties of packable and conventional posterior resin-based composites: A comparison [J].
Cobb, DS ;
Macgregor, KM ;
Vargas, MA ;
Denehy, GE .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2000, 131 (11) :1610-1615
[5]   Statistical estimation of resin composite polymerization sufficiency using microhardness [J].
Cohen, ME ;
Leonard, DL ;
Charlton, DG ;
Roberts, HW ;
Ragain, JC .
DENTAL MATERIALS, 2004, 20 (02) :158-166
[6]   POLYMERIZATION KINETICS OF RESIN-BASED RESTORATIVE MATERIALS [J].
COOK, WD ;
STANDISH, PM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (02) :275-282
[7]  
*DENTSPL, 1998, DIR US SUR
[8]   A COMPARISON OF 4 MODES OF EVALUATING DEPTH OF CURE OF LIGHT-ACTIVATED COMPOSITES [J].
DEWALD, JP ;
FERRACANE, JL .
JOURNAL OF DENTAL RESEARCH, 1987, 66 (03) :727-730
[9]   RELATIONSHIP BETWEEN SHADE AND DEPTH OF CURE FOR LIGHT-ACTIVATED DENTAL COMPOSITE RESINS [J].
FERRACANE, JL ;
ADAY, P ;
MATSUMOTO, H ;
MARKER, VA .
DENTAL MATERIALS, 1986, 2 (02) :80-84
[10]  
Ferracane JL, 2003, AM J DENT, V16, P318