Carbon paste-based ion-selective dual function microelectrodes for SECM measurements

被引:16
作者
Csoka, Balazs [1 ]
Mekhalif, Zineb [1 ]
机构
[1] Univ Namur FUNDP, Lab Chem & Electrochem Surfaces, B-5000 Namur, Belgium
关键词
Ion-selective electrode; Carbon paste; SECM; Copper; Potentiometry; SCANNING ELECTROCHEMICAL MICROSCOPY; TECHNICAL REPORT; THIURAM DISULFIDE; ELECTRODE; COPPER(II); POTENTIOMETRY; DISSOLUTION; SENSORS;
D O I
10.1016/j.electacta.2008.10.067
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A description of the preparation and characterization of 25 mu m diameter modified carbon paste-based Cu2+ ion-selective electrodes are reported. The electrodes have a linear potential response within the 10(-3) to 10(-6) M range and a 16 s response time. A substantial benefit of this new type of ion-selective microelectrode (ISME) is the capability to use them as a dual function tip, in either the amperometric or the potentiometric mode of scanning electrochemical microscopy (SECM). The applications reported also support the usefulness of copper ion-selective carbon paste microelectrodes in SECM potentiometric imaging. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3225 / 3232
页数:8
相关论文
共 42 条
[1]   Gallamine-tetraphenylborate-modified carbon paste electrode for the potentiometric determination of gallamine triethiodide (Flaxedil) [J].
Abbas, MN ;
Mostafa, GAE .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (04) :819-826
[2]   A selective modified carbon paste electrode for determination of cyanide using tetra-3,4-pyridinoporphyrazinatocobalt(II) [J].
Abbaspour, A ;
Asadi, M ;
Ghaffarinejad, A ;
Safaei, E .
TALANTA, 2005, 66 (04) :931-936
[3]   Chemically modified carbon paste electrode for determination of copper(II) by potentiometric method [J].
Abbaspour, A ;
Moosavi, SMM .
TALANTA, 2002, 56 (01) :91-96
[4]   Imaging of metal ion dissolution and electrodeposition by anodic stripping voltammetry-scanning electrochemical microscopy [J].
Alpuche-Aviles, Mario A. ;
Baur, John E. ;
Wipf, David O. .
ANALYTICAL CHEMISTRY, 2008, 80 (10) :3612-3621
[5]   Cobalt(II) salophen-modified carbon-paste electrode for potentiometric and voltammetric determination of cysteine [J].
Amini, MK ;
Khorasani, JH ;
Khaloo, SS ;
Tangestaninejad, S .
ANALYTICAL BIOCHEMISTRY, 2003, 320 (01) :32-38
[6]   Electrochemical sensors [J].
Bakker, Eric ;
Qin, Yu .
ANALYTICAL CHEMISTRY, 2006, 78 (12) :3965-3983
[7]   A COMPARISON OF THE CHRONOAMPEROMETRIC RESPONSE AT INLAID AND RECESSED DISK MICROELECTRODES [J].
BOND, AM ;
LUSCOMBE, D ;
OLDHAM, KB ;
ZOSKI, CG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 249 (1-2) :1-14
[8]   Sphere-cap mercury microelectrodes for scanning electrochemical microscopy above an insulating substrate [J].
Daniele, S ;
Bragato, C ;
Ciani, I ;
Baldo, MA .
ELECTROANALYSIS, 2003, 15 (07) :621-628
[9]   SCANNING ELECTROCHEMICAL MICROSCOPY - POTENTIOMETRIC PROBING OF ION FLUXES [J].
DENUAULT, G ;
FRANK, MHT ;
PETER, LM .
FARADAY DISCUSSIONS, 1992, 94 :23-35
[10]   Constant-distance mode scanning potentiometry. 1. Visualization of calcium carbonate dissolution in aqueous solution [J].
Etienne, M ;
Schulte, A ;
Mann, S ;
Jordan, G ;
Dietzel, LD ;
Schuhmann, W .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3682-3688