Large volume sample stacking for rapid and sensitive determination of antidiabetic drug metformin in human urine and serum by capillary electrophoresis with contactless conductivity detection

被引:37
|
作者
Tuma, Petr [1 ]
机构
[1] Charles Univ Prague, Fac Med 3, Inst Biochem Cell & Mol Biol, Ruska 87, Prague 10000 10, Czech Republic
关键词
Antidiabetic drug; Capillary electrophoresis; Contact less conductivity detection; Large volume sample stacking; Rapid separation; PERIAQUEDUCTAL GRAY-MATTER; TYPE-2; DIABETES-MELLITUS; TANDEM MASS-SPECTROMETRY; ZONE-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; PHARMACEUTICAL-PREPARATIONS; DOSAGE FORMULATIONS; HUMAN PLASMA; AMINO-ACIDS; VALIDATION;
D O I
10.1016/j.chroma.2014.04.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two CE methods with contactless conductivity detection have been developed for determining the oral antidiabetic drug metformin in human urine and blood. The determination of metformin is performed on a separation capillary with an effective length of 14 cm, using a maximum voltage of 30 kV and with a small injection of 50-fold diluted urine into the capillary. Under these conditions, the migration time of metformin is 35 s and the LOD is 0.3 mu M Large-volume sample stacking was used to determine low metformin levels in serum. The injection of a sample of serum deproteinized with acetonitrile was 10 times greater compared to the injected amount of urine. This enabled reduction of the LOD to 0.03 mu M and the metformin migration time equalled 86 s. The undesirable solvent from sample zone was forced out of the capillary to ensure rapidity and good repeatability of the determination. The RSD values for the migration time are 0.1% for urine and 0.7% for serum; RSD for the peak areas equalled 1.4% for urine and 2.6% for serum. The developed CE technique was tested on performance of routine analyses of metformin in the urine and serum of patients suffering from type II diabetes mellitus. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:207 / 211
页数:5
相关论文
共 50 条
  • [21] The use of polarity switching for the sensitive determination of nitrate in human cerebrospinal fluid by capillary electrophoresis with contactless conductivity detection
    Tuma, Petr
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1447 : 148 - 154
  • [22] Application of capillary zone electrophoresis with large-volume sample stacking to the sensitive determination of sulfonamides in meat and ground water
    Soto-Chinchilla, Jorge J.
    Garcia-Campana, Ana M.
    Gamiz-Gracia, Laura
    Cruces-Blanco, Carmen
    ELECTROPHORESIS, 2006, 27 (20) : 4060 - 4068
  • [23] Determination of imatinib mesylate and related compounds by field amplified sample stacking with large volume sample injection capillary electrophoresis
    Li, Jian
    Huang, Yifei
    Huang, Lei
    Ye, Lei
    Zhou, Zhou
    Xiang, Guangya
    Xu, Li
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 26 - 31
  • [24] Sensitive determination of four β2-agonists in pig feed by capillary electrophoresis using on-line sample preconcentration with contactless conductivity detection
    Gao, Fan
    Wu, Minglei
    Zhang, Yi
    Wang, Guan
    Wang, Qingjiang
    He, Pingang
    Fang, Yuzhi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 973 : 29 - 32
  • [25] Sensitive Simultaneous Determination of Synthetic Food Colorants in Preserved Fruit Samples by Capillary Electrophoresis with Contactless Conductivity Detection
    Jia Yi
    Lewei Zeng
    Qiyan Wu
    Lirong Yang
    Tianyao Xie
    Food Analytical Methods, 2018, 11 : 1608 - 1618
  • [26] Determination of monoamines in urine by capillary electrophoresis with field-amplified sample stacking and amperometric detection
    Weng, QF
    Xu, GW
    Yuan, KL
    Tang, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 835 (1-2): : 55 - 61
  • [27] Online preconcentration in capillary electrophoresis with contactless conductivity detection for sensitive determination of sorbic and benzoic acids in soy sauce
    Wei, Ruixia
    Li, Wenhua
    Yang, Lirong
    Jiang, Yixiu
    Xie, Tianyao
    TALANTA, 2011, 83 (05) : 1487 - 1490
  • [28] Rapid determination of NSAIDs by capillary and microchip electrophoresis with capacitively coupled contactless conductivity detection in wastewater
    Alatawi, Hanan
    Hogan, Anna
    Albalawi, Ibtihaj
    O'Sullivan-Carroll, Emma
    Alsefri, Samia
    Wang, Yineng
    Moore, Eric
    ELECTROPHORESIS, 2022, 43 (20) : 1944 - 1952
  • [29] Determination of mercaptopurine and its four metabolites by large-volume sample stacking with polarity switching in capillary electrophoresis
    Wang, CC
    Chiou, SS
    Wu, SM
    ELECTROPHORESIS, 2005, 26 (13) : 2637 - 2642
  • [30] Detection of Escherichia coli by capillary electrophoresis assisted by large volume sample stacking and nicking endonuclease signal amplification
    Chu, Zhaohui
    Chen, Jingyi
    Zhang, Jingzi
    Xie, Qihui
    Zhang, Fan
    Wang, Qingjiang
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1706