Defocusing rectified multi-frequency patterns for high-precision 3D measurement

被引:10
作者
Huang, Hai-Qing [1 ]
Fang, Xiang-Zhong [1 ]
Zhang, Wei [2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Elect Informat & Elect Engn, Shanghai 200240, Peoples R China
[2] Huazhong Univ Sci & Technol, Dept Elect & Informat Engn, Hubei 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-frequency heterodyne; phase shift; phase unwrapping; DRMP; Gaussian smoothing; gamma correction; ADVANCED ITERATIVE ALGORITHM; GAMMA-CORRECTION; PHASE; PROJECTION; CALIBRATION;
D O I
10.1088/0957-0233/25/3/035009
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The sinuousness of the projected fringe patterns has a great influence on the accuracy of structured light-based 3D measurement. In this paper, a defocusing rectified multi-frequency patterns (DRMP) method is presented to eliminate the effect caused by the projector. The cause of phase error is derived and analyzed to prove the non-necessity of gamma correction in the DRMP method. First, the multi-frequency binary codes are projected onto the measured object, and a Gaussian smoothing filter is adopted to defocus the distorted fringe images captured by the imaging system. Then, an optimized phase unwrapping path which has the smallest phase error is proposed to obtain the unwrapped phase. After that, the stereo rectification and the two-step matching methods are applied to obtain the corresponding matching lines and points, respectively. Finally, we demonstrate that the proposed method can be implemented into the high-precision 3D shape measurement system. The validation experiments show that the proposed method is more precise and efficient compared with previous methods.
引用
收藏
页数:14
相关论文
共 29 条
[1]   Three-dimensional profiling with binary fringes using phase-shifting interferometry algorithms [J].
Ayubi, Gaston A. ;
Matias Di Martino, J. ;
Alonso, Julia R. ;
Fernandez, Ariel ;
Perciante, Cesar D. ;
Ferrari, Jose A. .
APPLIED OPTICS, 2011, 50 (02) :147-154
[2]   Photogrammetric calibration and accuracy evaluation of a cross-pattern stripe projector [J].
Brenner, C ;
Böhm, J ;
Gühring, J .
VIDEOMETRICS VI, 1998, 3641 :164-172
[3]   Calibration of a system of projection moire for relief measuring: biomechanical applications [J].
Breque, C ;
Dupre, JC ;
Bremand, F .
OPTICS AND LASERS IN ENGINEERING, 2004, 41 (02) :241-260
[4]   3D range optical sensor: analysis of the measurement errors and development of procedures for their compensation [J].
Carocci, M ;
Lazzari, S ;
Rodella, R ;
Sansoni, G .
THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS, 1998, 3313 :178-188
[5]   Blind inverse gamma correction [J].
Farid, H .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (10) :1428-1433
[6]   A new phase alignment method for digital projector in phase measuring profilometry [J].
Key Laboratory of Measurement and Control for Complex System of Ministry of Education, Southeast University, Nanjing 210096, China .
Zidonghua Xuebao Acta Auto. Sin., 2008, 11 (1363-1368) :1363-1368
[7]   A novel fringe adaptation method for digital projector [J].
Gai, Shaoyan ;
Da, Feipeng .
OPTICS AND LASERS IN ENGINEERING, 2011, 49 (04) :547-552
[8]   Absolute phase retrieval for 3D shape measurement by the Fourier transform method [J].
Guo, Hong ;
Huang, Peisen S. .
TWO- AND THREE-DIMENSIONAL METHODS FOR INSPECTION AND METROLOGY V, 2007, 6762
[9]   Gamma correction for digital fringe projection profilometry [J].
Guo, HW ;
He, HT ;
Chen, M .
APPLIED OPTICS, 2004, 43 (14) :2906-2914
[10]   Generic gamma correction for accuracy enhancement in fringe-projection profilometry [J].
Hoang, Thang ;
Pan, Bing ;
Nguyen, Dung ;
Wang, Zhaoyang .
OPTICS LETTERS, 2010, 35 (12) :1992-1994