Amperometric choline biosensors prepared by layer-by-layer deposition of choline oxidase on the Prussian blue-modified platinum electrode

被引:58
|
作者
Shi, Haibin
Yang, Yu
Huang, Jiadong
Zhao, Zixia
Xu, Xinhua
Anzai, Jun-ichi
Osa, Tetsuo
Chen, Qiang [1 ]
机构
[1] Nankai Univ, Coll Life Sci, Tianjin 300071, Peoples R China
[2] Tianjin Univ, Sch Mat Sci & Engn, Tianjin 300072, Peoples R China
[3] Tohoku Univ, Grad Sch Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9808578, Japan
基金
中国国家自然科学基金;
关键词
choline oxidase; amperometric biosensor; layer-by-layer; Prussian blue; 6-O-ethoxytrimethylammoniochitosan chloride;
D O I
10.1016/j.talanta.2006.02.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric choline biosensor was developed by immobilizing choline oxidase (ChOx) in a layer-by-layer (LBL) multilayer film on a platinum (Pt) electrode modified with Prussian blue (PB). 6-O-Ethoxytrimethylammoniochitosan chloride (EACC) was used to prepare the ChOx LBL films. The choline biosensor was used at 0.0 V versus Ag/AgCl to detect choline and exhibited good characteristics such as relative low detection limit (5 x 10(-7) M), short response time (within 10 s), high sensitivity (88.6 mu A mM(-1) cm(-2)) and a good selectivity. The results were explained based on the ultrathin nature of the LBL films and the low operating potential that could be due to the efficient catalytic reduction of H2O2 by PB. In addition, the effects of pH, temperature and applied potential on the amperometric response of choline biosensor were evaluated. The apparent Michaelis-Menten constant was found to be (0.083 +/- 0.001) x 10(-3) M. The biosensor showed excellent long-term storage stability, which originates from a strong adsorption of ChOx in the EACC multilayer film. When the present choline biosensor was applied to the analysis of phosphatidylcholine in serum samples, the measurement values agreed satisfactorily with those by a hospital method. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:852 / 858
页数:7
相关论文
共 50 条
  • [21] A Choline Oxidase Amperometric Bioassay for the Detection of Mustard Agents Based on Screen-Printed Electrodes Modified with Prussian Blue Nanoparticles
    Arduini, Fabiana
    Scognamiglio, Viviana
    Covaia, Corrado
    Amine, Aziz
    Moscone, Danila
    Palleschi, Giuseppe
    SENSORS, 2015, 15 (02): : 4353 - 4367
  • [22] Enzyme sensors prepared by layer-by-layer deposition of enzymes on a platinum electrode through avidin-biotin interaction
    Anzai, J
    Kobayashi, Y
    Suzuki, Y
    Takeshita, H
    Chen, Q
    Osa, T
    Hoshi, T
    Du, XY
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 52 (1-2) : 3 - 9
  • [23] Multilayer membranes via layer-by-layer deposition of organic polymer protected Prussian blue nanoparticles and glucose oxidase for glucose biosensing
    Zhao, W
    Xu, JJ
    Shi, CG
    Chen, HY
    LANGMUIR, 2005, 21 (21) : 9630 - 9634
  • [24] Indirect electrocatalytic determination of choline by monitoring hydrogen peroxide at the choline oxidase-prussian blue modified iron phosphate nanostructures
    Zhang, Hui
    Yin, Yajing
    Wu, Ping
    Cai, Chenxin
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 244 - 250
  • [25] An Amperometric Immunosensor Based on Layer-by-Layer Assembly of L-Cysteine and Nanosized Prussian Blue on Gold Electrode for Determination of Human Chorionic Gonadotrophin
    Wang, Jinfen
    Yuan, Ruo
    Chai, Yaqin
    Yin, Bing
    Xu, Yang
    Guan, Shu
    ELECTROANALYSIS, 2009, 21 (06) : 707 - 714
  • [26] Amperometric biosensor based on Prussian Blue-modified screen-printed electrode for lipase activity and triacylglycerol determination
    Rejeb, Ines Ben
    Arduini, Fabiana
    Amine, Aziz
    Gargouri, Mohamed
    Palleschi, Giuseppe
    ANALYTICA CHIMICA ACTA, 2007, 594 (01) : 1 - 8
  • [27] Chemically modified electrode via layer-by-layer deposition of glucose oxidase (GOD) and polycation-bearing Os complex
    Sun, YP
    Sun, JQ
    Zhang, X
    Sun, CQ
    Wang, Y
    Shen, JC
    THIN SOLID FILMS, 1998, 327 : 730 - 733
  • [28] Chemically modified electrode via layer-by-layer deposition of glucose oxidase (GOD) and polycation-bearing Os complex
    Sun, Yipeng
    Sun, Junqi
    Zhang, Xi
    Sun, Changqing
    Wang, Yue
    Shen, Jiacong
    Thin Solid Films, 1998, 327-329 : 730 - 733
  • [29] DNA as a support for glucose oxidase immobilization at Prussian blue-modified glassy carbon electrode in biosensor preparation
    Kafi, A. K. M.
    Lee, Dong-Yun
    Park, Sang-Hyun
    Kwon, Young-Soo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2006, 6 (11) : 3539 - 3542
  • [30] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    TENG YuanJieCHEN ChenZHOU ChangXiangZHAO HongLi LAN MinBo Shanghai key Laboratory of Functional Materials Chemistry
    Research Center of Analysis TestEast China University of Science and TechnologyShanghai China
    Science China(Chemistry), 2010, 53 (12) : 2581 - 2586