Amperometric choline biosensors prepared by layer-by-layer deposition of choline oxidase on the Prussian blue-modified platinum electrode

被引:58
|
作者
Shi, Haibin
Yang, Yu
Huang, Jiadong
Zhao, Zixia
Xu, Xinhua
Anzai, Jun-ichi
Osa, Tetsuo
Chen, Qiang [1 ]
机构
[1] Nankai Univ, Coll Life Sci, Tianjin 300071, Peoples R China
[2] Tianjin Univ, Sch Mat Sci & Engn, Tianjin 300072, Peoples R China
[3] Tohoku Univ, Grad Sch Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9808578, Japan
基金
中国国家自然科学基金;
关键词
choline oxidase; amperometric biosensor; layer-by-layer; Prussian blue; 6-O-ethoxytrimethylammoniochitosan chloride;
D O I
10.1016/j.talanta.2006.02.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric choline biosensor was developed by immobilizing choline oxidase (ChOx) in a layer-by-layer (LBL) multilayer film on a platinum (Pt) electrode modified with Prussian blue (PB). 6-O-Ethoxytrimethylammoniochitosan chloride (EACC) was used to prepare the ChOx LBL films. The choline biosensor was used at 0.0 V versus Ag/AgCl to detect choline and exhibited good characteristics such as relative low detection limit (5 x 10(-7) M), short response time (within 10 s), high sensitivity (88.6 mu A mM(-1) cm(-2)) and a good selectivity. The results were explained based on the ultrathin nature of the LBL films and the low operating potential that could be due to the efficient catalytic reduction of H2O2 by PB. In addition, the effects of pH, temperature and applied potential on the amperometric response of choline biosensor were evaluated. The apparent Michaelis-Menten constant was found to be (0.083 +/- 0.001) x 10(-3) M. The biosensor showed excellent long-term storage stability, which originates from a strong adsorption of ChOx in the EACC multilayer film. When the present choline biosensor was applied to the analysis of phosphatidylcholine in serum samples, the measurement values agreed satisfactorily with those by a hospital method. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:852 / 858
页数:7
相关论文
共 50 条
  • [1] Amperometric glucose biosensors based on layer-by-layer assembly of chitosan and glucose oxidase on the Prussian blue-modified gold electrode
    Bing Yin
    Ruo Yuan
    Yaqing Chai
    Shihong Chen
    Shurui Cao
    Yang Xu
    Ping Fu
    Biotechnology Letters, 2008, 30 : 317 - 322
  • [2] Amperometric glucose biosensors based on layer-by-layer assembly of chitosan and glucose oxidase on the Prussian blue-modified gold electrode
    Yin, Bing
    Yuan, Ruo
    Chai, Yaqing
    Chen, Shihong
    Cao, Shurui
    Xu, Yang
    Fu, Ping
    BIOTECHNOLOGY LETTERS, 2008, 30 (02) : 317 - 322
  • [3] Effects of the type of polycation on the amperometric response of choline biosensors prepared by a layer-by-layer deposition technique
    Shi, HB
    Song, Z
    Huang, JD
    Yang, Y
    Zhao, ZX
    Anzai, J
    Osa, T
    Chen, Q
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2005, 25 (04): : 433 - 435
  • [4] Amperometric ethanol biosensor based on layer-by-layer deposition of alcohol oxidase on the platinum electrode
    Li, Sha
    Wang, Yanyan
    Zhao, Zixia
    Qin, Xia
    Wang, Xinsheng
    Wang, Huicai
    Yu, Min
    Miao, Zhiying
    Wu, Baoyan
    Chen, Qiang
    SENSOR LETTERS, 2008, 6 (02) : 347 - 351
  • [5] Effects of the type of polycation in the coating films prepared by a layer-by-layer deposition technique on the properties of amperometric choline sensors
    Shi, HB
    Song, Z
    Huang, JD
    Yang, Y
    Zhao, ZX
    Anzai, JI
    Osa, T
    Chen, Q
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 109 (02) : 341 - 347
  • [6] Amperometric choline biosensors based on multi-wall carbon nanotubes and layer-by-layer assembly of multilayer films composed of Poly(diallyldimethylammonium chloride) and choline oxidase
    Qin, Xia
    Wang, Huicai
    Wang, Xinsheng
    Li, Sha
    Miao, Zhiying
    Huang, Nan
    Chen, Qiang
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (04): : 1453 - 1457
  • [7] Glucose oxidase modified electrode fabricated by layer-by-layer molecular deposition
    Chen, ZC
    Xu, SH
    Lin, HF
    Yang, SM
    Lin, XF
    ACTA PHYSICO-CHIMICA SINICA, 2004, 20 (10) : 1267 - 1270
  • [8] Amperometric detection of hydrogen peroxide at a Prussian Blue-modified FTO electrode
    Tseng, KS
    Chen, LC
    Ho, KC
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) : 738 - 745
  • [9] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [10] Disposable amperometric immunosensor based on layer-by-layer electro-depositing of the nanogold particles, prussian blue-modified indium tin oxide for determination of α-fetoprotein
    Li, Yan
    Liang, Wen-Bin
    Fang, Li-Chao
    Huang, Hui
    Deng, Jun
    Zheng, Jun-Song
    JOURNAL OF CHEMICAL SCIENCES, 2009, 121 (06) : 1069 - 1076