Investigation on the charging process of a multi-PCM latent heat thermal energy storage unit for use in conventional air-conditioning systems

被引:65
作者
Li, Xiao-Yan [1 ]
Yang, Liu [1 ]
Wang, Xue-Lei [1 ]
Miao, Xin-Yue [1 ]
Yao, Yu [1 ]
Qiang, Qiu-Qiu [1 ]
机构
[1] Harbin Univ Commerce, Sch Energy & Bldg Engn, 1 Xuehai St, Harbin 150028, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Conventional air-conditioning system; Thermal energy storage; Multiple phase change materials; Numerical simulation; Charging characteristics; PHASE-CHANGE-MATERIALS; DISCHARGING PROCESS; DYNAMIC CHARACTERISTICS; SINGLE-PCM; PERFORMANCE; CONFIGURATION; BEHAVIOR; PLANT;
D O I
10.1016/j.energy.2018.02.107
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to improve the performance of thermal energy storage (TES) systems, a multiple phase change material (multi-PCM) based TES unit for use in conventional air-conditioning systems was studied. Three PCMs (PCM-1, PCM-2, and PCM-3) with phase change temperatures of 5.3 degrees C, 6.5 degrees C and 10 degrees C, respectively, were used. Water was used as the heat transfer fluid (HTF). A three-dimensional model (3D) was developed in ANSYS FLUENT to investigate the charging process of multi-PCM TES unit. In order to validate the model, an experimental system was set up. The effect of volume ratio of multi-PCM, HTF inlet temperature and flow rate on the charging process of TES unit was investigated. The simulation results indicate that TES unit using multi-PCM with volume ratio 1:2:3 intensify the charging process in comparison with using single-PCM. The total charging capacity of multi-PCM TES unit with 1:2:3 proportions was 3637.2 kJ and increased by approximately 32.22% as compared to the single-PCM. For the HTF flow rate of 0.3 kg/s, decreasing the inlet temperature of HTF sped up the charging capacity, and obviously shortened the complete charging time of TES unit. However, the HTF inlet temperature did not appreciably change the total charging capacity. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:591 / 600
页数:10
相关论文
共 29 条
[11]   Investigating PCM activation using transient plane source method [J].
Johansson, Par ;
Kalagasidis, Angela Sasic ;
Jansson, Helen .
6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 :800-805
[12]   Enhancement of heat transfer for thermal energy storage application using stearic acid nanocomposite with multi-walled carbon nanotubes [J].
Li, TingXian ;
Lee, Ju-Hyuk ;
Wang, RuZhu ;
Kang, Yong Tae .
ENERGY, 2013, 55 :752-761
[13]   Experimental and numerical investigation of discharging process of direct contact thermal energy storage for use in conventional air-conditioning systems [J].
Li, Xiao-Yan ;
Qu, Dong-Qi ;
Yang, Liu ;
Li, Kai-Di .
APPLIED ENERGY, 2017, 189 :211-220
[14]   Investigation on the dynamic characteristics of a direct contact thermal energy storage charging process for use in conventional air-conditioning systems [J].
Li, Xiao-Yan ;
Zhao, Qiao-Qiao ;
Qu, Dong-Qi .
APPLIED THERMAL ENGINEERING, 2015, 91 :172-180
[15]   Investigation of the dynamic characteristics of a storage tank discharging process for use in conventional air-conditioning system [J].
Li, Xiao-Yan ;
Li, Li ;
Yu, Jia-Wen ;
Liu, Jia-Qing ;
Wu, Yan-Yan .
SOLAR ENERGY, 2013, 96 :300-310
[16]   Experimental validation of the exact analytical solution to the steady periodic heat transfer problem in a PCM layer [J].
Mazzeo, Domenico ;
Oliveti, Giuseppe ;
de Gracia, Alvaro ;
Coma, Julia ;
Sole, Aran ;
Cabeza, Luisa F. .
ENERGY, 2017, 140 :1131-1147
[17]   Experimental evaluation of commercial heat exchangers for use as PCM thermal storage systems [J].
Medrano, M. ;
Yilmaz, M. O. ;
Nogues, M. ;
Martorell, I. ;
Roca, Joan ;
Cabeza, Luisa F. .
APPLIED ENERGY, 2009, 86 (10) :2047-2055
[18]   Energy and exergy evaluation of a multiple-PCM thermal storage unit for free cooling applications [J].
Mosaffa, A. H. ;
Farshi, L. Garousi ;
Ferreira, C. A. Infante ;
Rosen, M. A. .
RENEWABLE ENERGY, 2014, 68 :452-458
[19]   Thermal performance of a multiple PCM thermal storage unit for free cooling [J].
Mosaffa, A. H. ;
Ferreira, C. A. Infante ;
Talati, F. ;
Rosen, M. A. .
ENERGY CONVERSION AND MANAGEMENT, 2013, 67 :1-7
[20]   Experimental evaluation at pilot plant scale of multiple PCMs (cascaded) vs. single PCM configuration for thermal energy storage [J].
Peiro, Gerard ;
Gasia, Jaume ;
Miro, Laia ;
Cabeza, Luisa F. .
RENEWABLE ENERGY, 2015, 83 :729-736