Objective: To describe our experience with removal of pacing lead in children using different techniques. Patients and Methods: Between 1999 and 2006, removal of 39 leads was attempted in 30 patients: 21 males and 9 females aged 4-21 years (mean 12 +/- 5 years). Sixteen patients had previous corrective cardiac surgery. The leads had been implanted for 46 +/- 31 months (range 1-120 months). The reasons for removal included lead fracture in 14, upgrading in 8, infection in 7, dislodgment in 5, pacing system not needed in 2, and other reasons in 3. Results: Of the 39 leads, 29 (74.3%) were completely removed. Twelve leads were removed with simple traction and rotation and 9 were removed using a locking stylet combined with simple traction and rotation; a laser extraction system was used in 10 cases in which 8 leads were successfully removed. Duration of implantation was the only important predictor for successful removal. Three patients necessitated surgical lead removal and had epicardial pacemaker implantation. Conclusion: Using currently available techniques, percutaneous pacemaker lead removal was possible in the majority of cases, although a significant number of cases were not successful. Attempted lead removal with simple traction and rotation resulted in the need for surgical removal in a significant number of patients. Newer techniques should be developed to increase the success rate. Copyright (C) 2009 S. Karger AG, Basel
引用
收藏
页码:356 / 359
页数:4
相关论文
共 11 条
[1]   Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996 [J].
Byrd, CL ;
Wilkoff, BL ;
Love, CJ ;
Sellers, TD ;
Turk, KT ;
Reeves, R ;
Young, R ;
Crevey, B ;
Kutalek, SP ;
Freedman, R ;
Friedman, R ;
Trantham, J ;
Watts, M ;
Schutzman, J ;
Oren, J ;
Wilson, J ;
Gold, F ;
Fearnot, NE ;
Van Zandt, HJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (09) :1348-1357
[2]  
Byrd CL, 1997, PACE, V20, P1053
[3]   Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads [J].
Candinas, R ;
Duru, F ;
Schneider, J ;
Lüscher, TF ;
Stokes, K .
MAYO CLINIC PROCEEDINGS, 1999, 74 (02) :120-125
[4]   Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: Implications for implantation and management [J].
Cooper, JM ;
Stephenson, EA ;
Berul, CI ;
Walsh, EP ;
Epstein, LM .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (04) :344-349
[5]  
Friedman RA, 1996, PACE, V19, P778
[6]  
Love CJ, 2000, PACE, V23, P544
[7]   Effectiveness of excimer laser-assisted pacing and ICD lead extraction in children and young adults [J].
Moak, JP ;
Freedenberg, V ;
Ramwell, C ;
Skeete, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (05) :461-466
[8]   Laser-assist during extraction of chronically implanted pacemaker and defibrillator leads [J].
Moon, MR ;
Camillo, CJ ;
Gleva, MJ .
ANNALS OF THORACIC SURGERY, 2002, 73 (06) :1893-1896
[9]   Laser extraction of entrapped leads [J].
Parsonnet, V ;
Roelke, M ;
Trivedi, A ;
Rizvi, SA ;
Pervez, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (03) :329-332
[10]   VENOUS COMPLICATIONS AFTER INSERTION OF A TRANSVENOUS PACEMAKER [J].
SPITTELL, PC ;
HAYES, DL .
MAYO CLINIC PROCEEDINGS, 1992, 67 (03) :258-265