Cascade Control of Grid-Connected PV Systems Using TLBO-Based Fractional-Order PID

被引:5
作者
Badis, Afef [1 ]
Mansouri, Mohamed Nejib [1 ]
Boujmil, Mohamed Habib [2 ]
机构
[1] Univ Monastir, Natl Engn Sch Monastir ENIM, Elect & Microelect Lab E E, Monastir, Tunisia
[2] Higher Inst Technol Studies Nabeul, Nabeul, Tunisia
关键词
Artificial intelligence - Cascade control systems - Controllers - Genetic algorithms - MATLAB - Particle swarm optimization (PSO);
D O I
10.1155/2019/4325648
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Cascade control is one of the most efficient systems for improving the performance of the conventional single-loop control, especially in the case of disturbances. Usually, controller parameters in the inner and the outer loops are identified in a strict sequence. This paper presents a novel cascade control strategy for grid-connected photovoltaic (PV) systems based on fractional-order PID (FOPID). Here, simultaneous tuning of the inner and the outer loop controllers is proposed. Teaching-learning-based optimization (TLBO) algorithm is employed to optimize the parameters of the FOPID controller. The superiority of the proposed TLBO-based FOPID controller has been demonstrated by comparing the results with recently published optimization techniques such as genetic algorithm (GA), particle swarm optimization (PSO), and ant colony optimization (ACO). Simulations are conducted using MATLAB/Simulink software under different operating conditions for the purpose of verifying the effectiveness of the proposed control strategy. Results show that the performance of the proposed approach provides better dynamic responses and it outperforms the other control techniques.
引用
收藏
页数:17
相关论文
共 33 条
[11]   OPTIMIZATION OF CONTROL PARAMETERS FOR GENETIC ALGORITHMS [J].
GREFENSTETTE, JJ .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1986, 16 (01) :122-128
[12]  
Hang C. C., 1994, IEEE Transactions on Control Systems Technology, V2, P42, DOI 10.1109/87.273109
[13]   Model Predictive Control of Grid-Connected Inverters for PV Systems With Flexible Power Regulation and Switching Frequency Reduction [J].
Hu, Jiefeng ;
Zhu, Jianguo ;
Dorrell, David G. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (01) :587-594
[14]   Improved cascade control structure for enhanced performance [J].
Kaya, Ibrahim ;
Tan, Nusret ;
Atherton, Derek P. .
JOURNAL OF PROCESS CONTROL, 2007, 17 (01) :3-16
[15]  
Kennedy J, 1995, 1995 IEEE INTERNATIONAL CONFERENCE ON NEURAL NETWORKS PROCEEDINGS, VOLS 1-6, P1942, DOI 10.1109/icnn.1995.488968
[16]   Overview of Maximum Power Point Tracking Techniques for Photovoltaic Energy Production Systems [J].
Koutroulis, Eftichios ;
Blaabjerg, Frede .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (12) :1329-1351
[17]   WHEN TO USE CASCADE CONTROL [J].
KRISHNASWAMY, PR ;
RANGAIAH, GP ;
JHA, RK ;
DESHPANDE, PB .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1990, 29 (10) :2163-2166
[18]   PID controller tuning to obtain desired closed loop responses for cascade control systems [J].
Lee, Y ;
Park, S ;
Lee, M .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1998, 37 (05) :1859-1865
[19]  
Lhomme W, 2012, 2012 15TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE/PEMC)
[20]   Decoupling two-degree-of-freedom control strategy for cascade control systems [J].
Liu, T ;
Gu, DY ;
Zhang, WD .
JOURNAL OF PROCESS CONTROL, 2005, 15 (02) :159-167