Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization

被引:20
作者
Bulem, Ureyen Kaya [1 ]
Kececi, Ayse Diljin [1 ]
Guldas, Hilmi Egemen [1 ]
机构
[1] Suleyman Demirel Univ, Fac Dent, Dept Endodont, TR-32260 Isparta, Turkey
关键词
Endodontics; Fractures; Sterilization; Stress; Sodium chloride; ROTARY INSTRUMENTS; ENDODONTIC INSTRUMENTS; MECHANICAL-PROPERTIES; FRACTURE PROPERTIES; CLINICAL-USE; PART; FILES; CORROSION; DEFECTS; SURFACE;
D O I
10.1590/1679-775720130083
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. Objective: To assess the effects of NaOCl immersion and autoclave sterilization on the cyclic fatigue resistance of ProFile, FlexMaster, Mtwo and TwistedFiles NiTi instruments (tip size 25, 0.06 taper, n=160). Material and Methods: The instruments (n=10 for each subgroup) were dynamically immersed in NaOCl; immersed in NaOCl and sterilized in one autoclave cycle; 5 cycles immersed in NaOCl and sterilized in autoclave and not immersed in NaOCl and not sterilized (control group). Dynamic cyclic fatigue resistance was tested. The number of cycles to failure (NCF) were statistically analyzed (P<0.05). Results: Kruskall-Wallis test indicated significant differences among the tested instruments in terms of NCF (P=0.000). The mean NCF of Mtwo (556.75) was higher than that of the Twisted File, Flexnnaster and ProFile, 483.1, 376.12, 365.25, respectively. NaOCl immersion and autoclave sterilization have no effect on the NCF values of the tested instruments (P>.05). Conclusions: Cyclic fatigue resistance of the tested NiTi instruments cannot be adversely affected by NaOCl immersion and autoclave sterilization. Production process (TwistedFiles) or design (Twisted Files, FlexMaster, Mtwo and ProFile) of the instruments can influence their cyclic fatigue resistance.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 31 条
[1]   SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use [J].
Alapati, SB ;
Brantley, WA ;
Svec, TA ;
Powers, JM ;
Nusstein, JM ;
Daehn, GS .
JOURNAL OF ENDODONTICS, 2005, 31 (01) :40-43
[2]  
Arruda Marcos Pôrto de, 2009, Braz. Dent. J., V20, P284
[3]   Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals [J].
Bahia, MGA ;
Buono, VTL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 100 (02) :249-255
[4]   Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments [J].
Berutti, E. ;
Angelini, E. ;
Rigolone, M. ;
Migliaretti, G. ;
Pasqualini, D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (09) :693-699
[5]   Fatigue testing of a NiTi rotary instrument. Part 2: fractographic analysis [J].
Cheung, G. S. P. ;
Darvell, B. W. .
INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (08) :619-625
[6]  
de Melo MCC, 2002, J ENDODONT, V28, P765
[7]   Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors [J].
Gambarini, G .
JOURNAL OF ENDODONTICS, 2001, 27 (12) :772-774
[8]   Cyclic fatigue of Profile rotary instruments after prolonged clinical use [J].
Gambarini, G .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (05) :386-389
[9]   Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods [J].
Gambarini, Gianluca ;
Grande, Nicola Maria ;
Plotino, Gianluca ;
Somma, Francesco ;
Garala, Manish ;
De Luca, Massimo ;
Testarelli, Luca .
JOURNAL OF ENDODONTICS, 2008, 34 (08) :1003-1005
[10]   Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment [J].
Haikel, Y ;
Serfaty, R ;
Wilson, P ;
Speisser, JM ;
Allemann, C .
JOURNAL OF ENDODONTICS, 1998, 24 (11) :731-735