Wake Effect of a Horizontal Axis Wind Turbine on the Performance of a Downstream Turbine

被引:23
|
作者
Tang, Haojun [1 ]
Lam, Kit-Ming [2 ]
Shum, Kei-Man [3 ]
Li, Yongle [1 ]
机构
[1] Southwest Jiaotong Univ, Dept Bridge Engn, Chengdu 610031, Sichuan, Peoples R China
[2] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Kowloon, Clear Water Bay, Hong Kong, Peoples R China
[3] Hong Kong Univ Sci & Technol, CLP Power Wind Wave Tunnel Facil, Kowloon, Clear Water Bay, Hong Kong, Peoples R China
关键词
wind turbines; wind tunnel test; turbine wake; tandem arrangement; REYNOLDS-NUMBER; BLADE; FLOW; LOSSES; ROTOR;
D O I
10.3390/en12122395
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents wind tunnel tests on the wake characteristics of a three-blade horizontal axis wind turbine and the wake effect on the performance of a downstream turbine. For a single turbine model, the performance was determined and this was followed by measurement of the wind characteristics including velocities, turbulence intensities, and correlation in the wake flow field. Subsequently, taking two horizontal axis wind turbines in a tandem arrangement into account, their performance was tested and the aerodynamic mechanism was discussed. The results showed that the upstream turbine with blades set at a small pitch angle provided smaller disturbance to the flow, but as the blade turned faster, larger changes in the velocity and the turbulence intensity occurred in its wake due to the more frequent disturbance of the wind turbine. The correlation of wake velocities in the turbine swept area also obviously decreased from the free-stream situation. For the downstream turbine, the output power loss largely depended on the wake characteristics of the upstream turbine, which was closely related to lower wind velocities or higher turbulence intensities. The decrease in correlation of the streamwise velocity within the blade swept area is accompanied by the increased correlation of the tangential velocity, which may be beneficial to the downstream turbine's performance.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] The effect of the boundary layer on the wake of a horizontal axis wind turbine
    Sedaghatizadeh, Nima
    Arjomandi, Maziar
    Kelso, Richard
    Cazzolato, Benjamin
    Ghayesh, Mergen H.
    ENERGY, 2019, 182 : 1202 - 1221
  • [2] Performance and near wake measurements of a model horizontal axis wind turbine
    Krogstad, Per-Age
    Adaramola, Muyiwa S.
    WIND ENERGY, 2012, 15 (05) : 743 - 756
  • [3] Investigation of flow downstream a horizontal axis wind turbine
    Massouh, Fawaz
    Dobrev, Ivan
    2006 FIRST INTERNATIONAL SYMPOSIUM ON ENVIRONMENT IDENTITIES AND MEDITERRANEAN AREA, VOLS 1 AND 2, 2006, : 133 - +
  • [4] Numerical Simulation in the Wake of a Horizontal Axis Wind Turbine
    Li, Deshun
    Li, Rennian
    Yang, Congxin
    Wang, Xiuyong
    Wang, Xin
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [5] LOADS ON A HORIZONTAL AXIS WIND TURBINE OPERATING IN WAKE
    VOLUND, P
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 39 (1-3) : 317 - 328
  • [6] Rigid wake model for a horizontal axis wind turbine
    Kotb, M.A.
    Abdel Haq, M.M.
    Wind Engineering, 1992, 16 (02) : 95 - 108
  • [7] Effect of steady and transient wind shear on the wake structure and performance of a horizontal axis wind turbine rotor
    Sezer-Uzol, Nilay
    Uzol, Oguz
    WIND ENERGY, 2013, 16 (01) : 1 - 17
  • [8] Effect of transient wind shear and dynamic inflow on the wake structure and performance of horizontal axis wind turbine
    Zhou, W. (wenpz@sina.com), 1600, Chinese Society for Electrical Engineering (32):
  • [9] Effect of winglet geometry on horizontal axis wind turbine performance
    Mourad, Mina G.
    Shahin, Ibrahim
    Ayad, Samir S.
    Abdellatif, Osama E.
    Mekhail, Tarek A.
    ENGINEERING REPORTS, 2020, 2 (01)
  • [10] NEAR WAKE OF A MODEL HORIZONTAL-AXIS WIND TURBINE
    HU Dan-mei School of Power and Enviromental Engineering