Validation of a new HPLC-UV method for determination of the antibiotic linezolid in human plasma and in bronchoalveolar lavage

被引:26
作者
Fortuna, Serena [1 ]
De Pascale, Gennaro [2 ]
Ragazzoni, Enzo [1 ]
Antonelli, Massimo [2 ]
Navarra, Pierluigi [1 ]
机构
[1] Catholic Univ, Sch Med, Clin Pharmacol Unit, Agostino Gemelli Acad Hosp, Rome, Italy
[2] Catholic Univ, Sch Med, Dept Intens Care & Anesthesiol, Agostino Gemelli Acad Hosp, Rome, Italy
关键词
linezolid; HPLC-UV; solid-phase extraction; therapeutic drug monitoring; BAL; PERFORMANCE LIQUID-CHROMATOGRAPHY; VENTILATOR-ASSOCIATED PNEUMONIA; CRITICALLY-ILL PATIENTS; MASS-SPECTROMETRY; CONTINUOUS-INFUSION; SAMPLE PREPARATION; PHARMACOKINETICS; EXTRACTION; OUTCOMES; PATIENT;
D O I
10.1002/bmc.2947
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and selective HPLC-UV method was developed for the quantification of linezolid (LNZ) in human plasma and bronchoalveolar lavage (BAL) at the concentrations associated with therapy. Plasma samples were extracted by solid-phase extraction followed by evaporation to dryness and reconstitution in mobile phase solution. The chromatographic separation was carried out on a C-18 column with an isocratic mobile phase consisting of dihydrogen phosphate buffer 50mm (pH3.5) and acetonitrile (60:40v/v). The detection was performed using a photodiode array. Under these conditions, a single chromatographic run could be completed within 12min. The method was validated by estimating the precision and the accuracy for inter- and intra-day analysis in the concentration range of 25-25600ng/mL. The method was linear over the investigated range with all the correlation coefficients R>0.999. The intra- and inter-day precision was within 8.90% and the accuracy ranged from -4.76 to +5.20%. This rapid and sensitive method was fully validated and could be applied to pharmacokinetic study for the determination of LNZ levels in human plasma and BAL samples. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:1489 / 1496
页数:8
相关论文
共 27 条
[11]   Intrapulmonary pharmacokinetics of linezolid [J].
Conte, JE ;
Golden, JA ;
Kipps, J ;
Zurlinden, E .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2002, 46 (05) :1475-1480
[12]  
De Pascale G, 2012, MINERVA ANESTESIOL, V78, P1418
[13]   Linezolid pharmacokinetics and pharmacodynamics in clinical treatment [J].
Dryden, Matthew S. .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2011, 66 :IV7-IV15
[14]   A new and rapid method for monitoring the new oxazolidinone antibiotic linezolid in serum and urine by high performance liquid chromatography-integrated sample preparation [J].
Ehrlich, M ;
Trittler, R ;
Daschner, FD ;
Kümmerer, K .
JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2) :373-377
[15]   The influence of inadequate antimicrobial treatment of bloodstream infections on patient outcomes in the ICU setting [J].
Ibrahim, EH ;
Sherman, G ;
Ward, S ;
Fraser, VJ ;
Kollef, MH .
CHEST, 2000, 118 (01) :146-155
[16]   Clinical importance of delays in the initiation of appropriate antibiotic treatment for ventilator-associated pneumonia [J].
Iregui, M ;
Ward, S ;
Sherman, G ;
Fraser, VJ ;
Kollef, MH .
CHEST, 2002, 122 (01) :262-268
[17]   The antimicrobial therapy puzzle: Could pharmacokinetic-pharmacodynamic relationships be helpful in addressing the issue of appropriate pneumonia treatment in critically ill patients? [J].
Pea, Federico ;
Viale, Pierluigi .
CLINICAL INFECTIOUS DISEASES, 2006, 42 (12) :1764-1771
[18]   Therapeutic drug monitoring may improve safety outcomes of long-term treatment with linezolid in adult patients [J].
Pea, Federico ;
Viale, Pierluigi ;
Cojutti, Piergiorgio ;
Del Pin, Barbara ;
Zamparini, Eleonora ;
Furlanut, Mario .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2012, 67 (08) :2034-2042
[19]   Therapeutic Drug Monitoring of Linezolid: a Retrospective Monocentric Analysis [J].
Pea, Federico ;
Furlanut, Mario ;
Cojutti, Piergiorgio ;
Cristini, Francesco ;
Zamparini, Eleonora ;
Franceschi, Loretta ;
Viale, Pierluigi .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2010, 54 (11) :4605-4610
[20]   Determination of linezolid in plasma by reversed-phase high-performance liquid chromatography [J].
Peng, GW ;
Stryd, RP ;
Murata, S ;
Igarashi, M ;
Chiba, K ;
Aoyama, H ;
Aoyama, M ;
Zenki, T ;
Ozawa, N .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) :65-73