Comparative Efficacy of New Interfaces for Intra-procedural Imaging Review: the Microsoft Kinect, Hillcrest Labs Loop Pointer, and the Apple iPad

被引:12
作者
Chao, Cherng [1 ]
Tan, Justin [1 ]
Castillo, Edward M. [1 ]
Zawaideh, Mazen [2 ]
Roberts, Anne C. [1 ]
Kinney, Thomas B. [1 ]
机构
[1] UCSD Med Ctr, San Diego, CA 92103 USA
[2] UCSD Sch Med, Rancho Santa Fe, CA 92067 USA
关键词
Computer interface; Gesture-based input device; Intra-procedural; GESTURE INTERFACE; VISUALIZATION; TOUCH; NAVIGATION; IMAGES;
D O I
10.1007/s10278-014-9687-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We adapted and evaluated the Microsoft Kinect (touchless interface), Hillcrest Labs Loop Pointer (gyroscopic mouse), and the Apple iPad (multi-touch tablet) for intra-procedural imaging review efficacy in a simulation using MIM Software DICOM viewers. Using each device, 29 radiologists executed five basic interactions to complete the overall task of measuring an 8.1-cm hepatic lesion: scroll, window, zoom, pan, and measure. For each interaction, participants assessed the devices on a 3-point subjective scale (3 = highest usability score). The five individual scores were summed to calculate a subjective composite usability score (max 15 points). Overall task time to completion was recorded. Each user also assessed each device for its potential to jeopardize a sterile field. The composite usability scores were as follows: Kinect 9.9 (out of 15.0; SD = 2.8), Loop Pointer 12.9 (SD = 13.5), and iPad 13.5 (SD = 1.8). Mean task completion times were as follows: Kinect 156.7 s (SD = 86.5), Loop Pointer 51.5 s (SD = 30.6), and iPad 41.1 s (SD = 25.3). The mean hepatic lesion measurements were as follows: Kinect was 7.3 cm (SD = 0.9), Loop Pointer 7.8 cm (SD = 1.1), and iPad 8.2 cm (SD = 1.2). The mean deviations from true hepatic lesion measurement were as follows: Kinect 1.0 cm and for both the Loop Pointer and iPad, 0.9 cm (SD = 0.7). The Kinect had the least and iPad had the most subjective concern for compromising the sterile field. A new intra-operative imaging review interface may be near. Most surveyed foresee these devices as useful in procedures, and most do not anticipate problems with a sterile field. An ideal device would combine iPad's usability and accuracy with the Kinect's touchless aspect.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 19 条
[1]   You Can't Touch This: Touch-free Navigation Through Radiological Images [J].
Ebert, Lars C. ;
Hatch, Gary ;
Ampanozi, Garyfalia ;
Thali, Michael J. ;
Ross, Steffen .
SURGICAL INNOVATION, 2012, 19 (03) :301-307
[2]   Three-dimensional imaging navigation during a lung segmentectomy using an iPad [J].
Eguchi, Takashi ;
Takasuna, Keiichiro ;
Kitazawa, Atsushi ;
Fukuzawa, Youhei ;
Sakaue, Yasuo ;
Yoshida, Kazuo ;
Matsubara, Makoto .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (04) :893-897
[3]  
GRAETZEL C, 2004, TECHNOL HEALTH CARE, V12, P245
[4]   Computer keyboard and mouse as a reservoir of pathogens in an intensive care unit [J].
Hartmann B. ;
Benson M. ;
Junger A. ;
Quinzio L. ;
Röhrig R. ;
Fengler B. ;
Färber U.W. ;
Wille B. ;
Hempelmann G. .
Journal of Clinical Monitoring and Computing, 2004, 18 (1) :7-12
[5]  
Hotker AM, 2013, INT J COMPUT ASSIST, V13, P13
[6]  
Johnson R., 2011, P SIGCHI C HUM FACT
[7]  
Kipshagen T, 2009, IFMBE PROC, V25, P75, DOI 10.1007/978-3-642-03906-5_21
[8]   A novel method for sterile intra-operative iPad use [J].
Murphy, A. D. ;
Belcher, H. J. C. R. .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2012, 65 (03) :403-404
[9]  
Padoy NHG, 2011, GESTURE BASED SURG M
[10]  
Ruppert GCAPH, 2011, GESTURE INTERFACE US