Measurement of angle Kappa with Orbscan II and Galilei G4: effect of accommodation

被引:31
作者
Dominguez-Vicent, Alberto [1 ]
Monsalvez-Romin, Daniel [1 ]
Perez-Vives, Cari [1 ]
Ferrer-Blasco, Teresa [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt, Optometry Res Grp GIO, E-46100 Burjassot, Spain
关键词
Angle Kappa; Accommodation; Orbscan II; Galilei G4; CORNEAL LIGHT REFLEX; OPTICAL ZONE; CENTRATION; DECENTRATION; LASIK; TILT; PUPIL;
D O I
10.1007/s00417-013-2509-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To measure angle kappa distance with Orbscan II and Galilei G4, and to evaluate possible variations in this value for different accommodation degrees. Angle kappa was measured using the Orbscan II and the Galilei G4 in the right eye of 80 patients aged from 20 to 40 years. This value was measured three times per eye and per device, and the average was retained. Angle kappa was measured for far vision using the Orbscan II and the Galilei G4 in a random order for each subject. The Galilei G4 was used to measure angle kappa as a function of accommodation, where the first measure started at +1 D and the vergence was changed until reaching -4 D, in 1 D steps. In both measures, the kappa distance was expressed in millimetres. At distance, the values of angle kappa were 0.43 +/- 0.13 mm and 0.27 +/- 0.15 mm measured with the Orbscan II and Galilei G4 systems respectively. Statistical significant differences were found (P < 0.01). With regard to the angle kappa values obtained as a function of accommodation, the values were 0.25 +/- 0.15 mm, 0.26 +/- 0.15 mm, 0.30 +/- 0.20 mm, 0.27 +/- 0.15 and 0.26 +/- 0.15 mm, for +1 D, -1 D, -2 D, -3 D and -4 D respectively. No statistical significant differences were found among 0 D and the other vergences evaluated (P > 0.01). For far vision, Orbscan II measured significantly higher angle kappa values than Galilei G4, the mean difference being 0.16 +/- 0.08 mm. For different accommodation levels, the kappa distance did not change significantly.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 25 条
[11]  
Merrill Kimberly S, 2012, Am Orthopt J, V62, P70, DOI 10.3368/aoj.62.1.70
[12]   Positive angle kappa in albinism [J].
Merrill, KS ;
Lavoie, JD ;
King, RA ;
Summers, CG .
JOURNAL OF AAPOS, 2004, 8 (03) :237-239
[13]   Laser in situ keratomileusis for hyperopia with the LADARVision 4000 with centration on the coaxially sighted corneal light reflex [J].
Nepomuceno, RL ;
Wachler, BSB ;
Kim, JM ;
Scruggs, R ;
Sato, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (06) :1281-1286
[14]   Reproducibility of intraocular lens decentration and tilt measurement using a clinical Purkinje meter [J].
Nishi, Yutaro ;
Hirnschall, Nino ;
Crnej, Alja ;
Gangwani, Vinod ;
Tabernero, Juan ;
Artal, Pablo ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) :1529-1535
[15]  
PANDE M, 1993, OPHTHALMOLOGY, V100, P1230
[16]   Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation [J].
Prakash, G. ;
Prakash, D. R. ;
Agarwal, A. ;
Kumar, D. A. ;
Agarwal, A. ;
Jacob, S. .
EYE, 2011, 25 (09) :1187-1193
[17]   Role of angle kappa in patient dissatisfaction with refractive-design multifocal intraocular lenses [J].
Prakash, Gaurav ;
Agarwal, Amar ;
Prakash, Dimple Rohit ;
Kumar, Dhivya Ashok ;
Agarwal, Athiya ;
Jacob, Soosan .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (09) :1739-1740
[18]   Topographic and biomechanical differences between hyperopic and myopic laser in situ keratomileusis [J].
Qazi, MA ;
Roberts, CJ ;
Mahmoud, AM ;
Pepose, JS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :48-60
[19]   Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses [J].
Ruiz-Alcocer, Javier ;
Perez-Vives, Caridad ;
Madrid-Costa, David ;
Lopez-Gil, Norberto ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (05) :327-+
[20]   Mechanism of compensation of aberrations in the human eye [J].
Tabernero, Juan ;
Benito, Antonio ;
Alcon, Encarna ;
Artal, Pablo .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (10) :3274-3283