Measurement of angle Kappa with Orbscan II and Galilei G4: effect of accommodation

被引:31
作者
Dominguez-Vicent, Alberto [1 ]
Monsalvez-Romin, Daniel [1 ]
Perez-Vives, Cari [1 ]
Ferrer-Blasco, Teresa [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt, Optometry Res Grp GIO, E-46100 Burjassot, Spain
关键词
Angle Kappa; Accommodation; Orbscan II; Galilei G4; CORNEAL LIGHT REFLEX; OPTICAL ZONE; CENTRATION; DECENTRATION; LASIK; TILT; PUPIL;
D O I
10.1007/s00417-013-2509-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To measure angle kappa distance with Orbscan II and Galilei G4, and to evaluate possible variations in this value for different accommodation degrees. Angle kappa was measured using the Orbscan II and the Galilei G4 in the right eye of 80 patients aged from 20 to 40 years. This value was measured three times per eye and per device, and the average was retained. Angle kappa was measured for far vision using the Orbscan II and the Galilei G4 in a random order for each subject. The Galilei G4 was used to measure angle kappa as a function of accommodation, where the first measure started at +1 D and the vergence was changed until reaching -4 D, in 1 D steps. In both measures, the kappa distance was expressed in millimetres. At distance, the values of angle kappa were 0.43 +/- 0.13 mm and 0.27 +/- 0.15 mm measured with the Orbscan II and Galilei G4 systems respectively. Statistical significant differences were found (P < 0.01). With regard to the angle kappa values obtained as a function of accommodation, the values were 0.25 +/- 0.15 mm, 0.26 +/- 0.15 mm, 0.30 +/- 0.20 mm, 0.27 +/- 0.15 and 0.26 +/- 0.15 mm, for +1 D, -1 D, -2 D, -3 D and -4 D respectively. No statistical significant differences were found among 0 D and the other vergences evaluated (P > 0.01). For far vision, Orbscan II measured significantly higher angle kappa values than Galilei G4, the mean difference being 0.16 +/- 0.08 mm. For different accommodation levels, the kappa distance did not change significantly.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 25 条
[1]   Measurement of angle kappa with synoptophore and Orbscan II in a normal population [J].
Basmak, Hikmet ;
Sahin, Afsun ;
Yildirim, Nilgun ;
Papakostas, Thanos D. ;
Kanellopoulos, A. John .
JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (05) :456-460
[2]   The Angle Kappa in Strabismic Individuals [J].
Basmak, Hikmet ;
Sahin, Afsun ;
Yildirim, Nilgun ;
Saricicek, Tuncer ;
Yurdakul, Sumru .
STRABISMUS, 2007, 15 (04) :193-196
[3]  
Benjamin WJ, 2006, BORISHS CLIN REFRACT, P385
[4]   Optical aberrations and alignment of the eye with age [J].
Berrio, Esther ;
Tabernero, Juan ;
Artal, Pablo .
JOURNAL OF VISION, 2010, 10 (14)
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Campos EC., 2002, Binocular Vision and Ocular Motility: Theory and Management of Strabismus, V6, P168
[7]  
Chan CCK, 2006, J REFRACT SURG, V22, P467
[8]   Corneal primary aberrations compensation by oblique light incidence [J].
Espinosa, Julian ;
Mas, David ;
Kasprzak, Henryk T. .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (04)
[9]   Distribution of Angle Kappa Measurements With Orbscan II in a Population-based Survey [J].
Hashemi, Hassan ;
KhabazKhoob, Mehdi ;
Yazdani, Kamran ;
Mehravaran, Shiva ;
Jafarzadehpur, Ebrahim ;
Fotouhi, Akbar .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (12) :966-971
[10]   Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration [J].
Madrid-Costa, David ;
Ruiz-Alcocer, Javier ;
Perez-Vives, Cari ;
Ferrer-Blasco, Teresa ;
Lopez-Gil, Norberto ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06) :947-958