High performance slit-less spectrometer for soft x-ray emission spectroscopy

被引:48
作者
Tokushima, T.
Harada, Y.
Ohashi, H.
Senba, Y.
Shin, S.
机构
[1] SPring 8, RIKEN, Sayo, Hyogo 6795148, Japan
[2] SPring 8, JASRI, Sayo, Hyogo 6795198, Japan
[3] Univ Tokyo, Inst Solid State Phys, Kashiwa, Chiba 2778581, Japan
关键词
D O I
10.1063/1.2204623
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have designed and constructed a new flat-field-type slit-less soft x-ray emission spectrometer that enables high detection efficiency and high energy resolution in the energy range of 250-1000 eV. The energy resolution is optimized in the C 1s and O 1s regions, where the maximum energy resolution of 2500 (E/Delta E) is expected using a focused beam whose spot size is 5 mu m full width at half maximum in the vertical direction. A distortion of the linear profile of the focused image on the charge-coupled device (CCD) detector is successfully removed by using a cylindrical grating. This enabled us to apply a super-resolution reconstruction technique to compensate for the lack of spatial resolution of the CCD detector.
引用
收藏
页数:5
相关论文
共 21 条
  • [1] HIGH-EFFICIENCY SOFT-X-RAY EMISSION SPECTROMETER FOR USE WITH SYNCHROTRON RADIATION EXCITATION
    CALLCOTT, TA
    TSANG, KL
    ZHANG, CH
    EDERER, DL
    ARAKAWA, ET
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (11) : 2680 - 2690
  • [2] High-resolution soft X-ray emission spectrograph at advanced light source
    Chuang, YD
    Pepper, J
    McKinney, W
    Hussain, Z
    Gullikson, E
    Batson, P
    Qian, D
    Hasan, MZ
    [J]. JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 2005, 66 (12) : 2173 - 2178
  • [3] Cocco D, 2004, AIP CONF PROC, V705, P873, DOI 10.1063/1.1757934
  • [4] Design and comparison of two photon spectrometers for soft x-ray emission spectroscopy
    Cocco, D
    Matteucci, M
    Prince, KC
    [J]. THEORY AND PRACTICE OF SURFACE-RELIEF DIFFRACTION GRATINGS: SYNCHROTRON AND OTHER APPLICATIONS, 1998, 3450 : 17 - 23
  • [5] Soft X-ray emission spectroscopy at ESRF beamline 26 based on a helical undulator
    Dallera, C
    Puppin, E
    Trezzi, G
    Incorvaia, N
    Fasana, A
    Braicovich, L
    Brookes, NB
    Goedkoop, JB
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1996, 3 : 231 - 238
  • [6] A helicity resolving soft X-ray emission spectrometer for studying magnetic circular dichroism with laboratory excitation sources
    Duda, LC
    Kuiper, P
    Mancini, DC
    Englund, CJ
    Nordgren, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 376 (02) : 291 - 297
  • [7] A simple spherical grating by-pass monochromator dedicated to soft x-ray emission spectroscopy
    Ghiringhelli, G
    Tagliaferri, A
    Braicovich, L
    Brookes, NB
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (04) : 1610 - 1615
  • [8] END STATION FOR POLARIZATION AND EXCITATION-ENERGY SELECTIVE SOFT-X-RAY FLUORESCENCE SPECTROSCOPY
    GUO, JH
    WASSDAHL, N
    SKYTT, P
    BUTORIN, SM
    DUDA, LC
    ENGLUND, CJ
    NORDGREN, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) : 1561 - 1563
  • [9] Plane-grating flat-field soft x-ray spectrometer
    Hague, CF
    Underwood, JH
    Avila, A
    Delaunay, R
    Ringuenet, H
    Marsi, M
    Sacchi, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (02) : 023110 - 1
  • [10] MECHANICALLY RULED ABERRATION-CORRECTED CONCAVE GRATINGS
    HARADA, T
    KITA, T