Methods for the measurement of the refractive index of MeV photons using total internal and external reflection

被引:1
|
作者
Aginian, M. A. [1 ]
Ispirian, K. A. [1 ]
Ispiryan, M. [1 ]
机构
[1] Yerevan Phys Inst, Alikhanian Natl Sci Lab, Yerevan 0036, Armenia
来源
RREPS13 AND MEGHRI13 | 2014年 / 517卷
关键词
D O I
10.1088/1742-6596/517/1/012045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recently it has been theoretically and experimentally shown that for 1-10 MeV and 1-2 MeV photons, respectively, the refractive index of Si is greater than 1. Taking into account the difficulties of the carried out experiment it is proposed to measure directly the refractive index of Si and other materials detecting the total internal and external reflections.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Refractive index measurement using total internal reflection
    Van Keuren, ER
    AMERICAN JOURNAL OF PHYSICS, 2005, 73 (07) : 611 - 614
  • [2] Gamma Cherenkov-transition radiation of high energy electrons and methods for the measurement of the refractive index of MeV photons using total internal and external reflections (Invited talk)
    Ispirian, K. A.
    RREPS13 AND MEGHRI13, 2014, 517
  • [3] Measurement method of the refractive index of biotissue by total internal reflection
    Li, H
    Xie, SS
    APPLIED OPTICS, 1996, 35 (10): : 1793 - 1795
  • [4] Refractive index measurement for biomaterial samples by total internal reflection
    Jin, Y. L.
    Chen, J. Y.
    Xu, L.
    Wang, P. N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (20): : N371 - N379
  • [5] Measurement and accuracy analysis of refractive index using a specular reflectivity close to the total internal reflection
    Li, H
    Lu, ZK
    Xie, SS
    Lin, L
    AUTOMATED OPTICAL INSPECTION FOR INDUSTRY: THEORY, TECHNOLOGY, AND APPLICATIONS II, 1998, 3558 : 491 - 497
  • [6] Refractive Index and Dispersion Measurement Principle with Polarization Change in Total Internal Reflection
    Chang, Jyun-Ping
    Tsai, Cheng-Mu
    Weng, Jun-Hong
    Han, Pin
    PHOTONICS, 2024, 11 (06)
  • [7] Experimental measurement of the refractive index of biological tissue's by total internal reflection
    Lai, JC
    Li, ZH
    Wang, CY
    He, AZ
    APPLIED OPTICS, 2005, 44 (10) : 1845 - 1849
  • [8] Effect of surface plasmon polaritons on the sensitivity of refractive index measurement using total internal reflection method
    Entezar, S. Roshan
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2015, 381 : 203 - 207
  • [9] Measurement of refractive index distribution using micro-lens array based on total internal reflection
    Chen, Junyao
    Guo, Wenping
    Yang, Kecheng
    Yin, Xiaojun
    Yu, Long
    PHYSICS AND SIMULATION OF OPTOELECTRONIC DEVICES XXV, 2017, 10098
  • [10] Dynamical measurement of refractive index distribution using digital holographic interferometry based on total internal reflection
    Zhang, Jiwei
    Di, Jianglei
    Li, Ying
    Xi, Teli
    Zhao, Jianlin
    OPTICS EXPRESS, 2015, 23 (21): : 27328 - 27334