A membrane introduction mass spectrometer utilizing ion-molecule reactions for the on-line speciation and quantitation of volatile organic molecules

被引:6
作者
Davey, Nicholas G. [1 ,2 ]
Bell, Ryan J. [2 ]
Krogh, Erik T. [1 ,2 ]
Gill, Chris G. [1 ,2 ]
机构
[1] Univ Victoria, Dept Chem, Victoria, BC, Canada
[2] Vancouver Isl Univ, Dept Chem, AERL, Nanaimo, BC V9R 5S5, Canada
关键词
CHEMICAL-IONIZATION; REAL-TIME; AIR; MIMS; SIMULATION; INTERFACE; ANALYTES; SYSTEM; WATER;
D O I
10.1002/rcm.7380
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE: The ability of membrane introduction mass spectrometry to quantitatively resolve low molecular weight volatile organic compounds (VOCs) such as benzene, toluene, ethylbenzene and xylene (BTEX) using electron ionization (EI) can be compromised by isobaric interferences. This work focuses on reducing isobaric interferences with ion-molecule reactions in a portable quadrupole ion trap mass spectrometer for the analysis of VOCs. METHODS: EI was used to produce reagent ions from precursors (chloroform, methyl iodide, trichloroethylene or chlorobenzene) that were continually infused into the helium acceptor phase upstream of the membrane introduction mass spectrometry (MIMS) sampling interface. The reagent ions were selectively stored in the ion trap, and then allowed to react with target VOC analytes in air samples via ion-molecule reactions within the trap storage volume. A variety of reaction times were examined (50-5000ms), and the resulting product ions were analyzed in positive ion mode. RESULTS: The detection limits achieved were comparable with those obtained using EI (low ppb(v)), and in some cases better than for EI coupled with tandem mass spectrometry (MS/MS). For the VOCs studied, isobaric interferences were greatly reduced or eliminated using chloroform as a reagent gas. The predominant ionization mechanism was via adduct formation, although charge transfer and hydride abstractions were also observed. An internal standard was shown to be effective at correcting for signal changes due to consumption of reagent ions when complex mixtures were sampled. CONCLUSIONS: Ion-molecule reactions were exploited to eliminate isobaric interferences that are often encountered in direct, real-time analysis strategies for atmospheric VOC mixtures. The use of a continuously infused internal standard will improve quantitative results in field applications where analyte concentration and sample complexity may be wide ranging. Copyright (C) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:2187 / 2194
页数:8
相关论文
共 44 条
[1]   Improving the selectivity of non-polar alkanes, alkenes, and aromatic hydrocarbon compounds by the application of acetonitrile as a CI reagent [J].
Alwedian, Fadel ;
Abu-Shandi, Khalid .
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2009, 7 (03) :312-316
[2]   Calibration of an in situ membrane inlet mass spectrometer for measurements of dissolved gases and volatile organics in seawater [J].
Bell, Ryan J. ;
Short, R. Timothy ;
Van Amerom, Friso H. W. ;
Byrne, Robert H. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (23) :8123-8128
[3]   A Field-Portable Membrane Introduction Mass Spectrometer for Real-time Quantitation and Spatial Mapping of Atmospheric and Aqueous Contaminants [J].
Bell, Ryan J. ;
Davey, Nicholas G. ;
Martinsen, Morten ;
Collin-Hansen, Christian ;
Krogh, Erik T. ;
Gill, Christopher G. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (02) :212-223
[4]   AN EXCEEDINGLY SIMPLE MASS-SPECTROMETER INTERFACE WITH APPLICATION TO REACTION MONITORING AND ENVIRONMENTAL-ANALYSIS [J].
BRODBELT, JS ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1985, 57 (06) :1153-1155
[5]  
Brodbelt JS, 1997, MASS SPECTROM REV, V16, P91, DOI 10.1002/(SICI)1098-2787(1997)16:2<91::AID-MAS3>3.0.CO
[6]  
2-4
[7]   Analysis ob polar organic compounds using charge exchange ionization and membrane introduction mass spectrometry [J].
Cisper, ME ;
Garrett, AW ;
Cameron, D ;
Hemberger, PH .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2097-2101
[8]   A fast-response method for determination of atmospheric isoprene using quadrupole ion trap mass spectrometry [J].
Colorado, A ;
Barket, DJ ;
Hurst, JM ;
Shepson, PB .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5129-5135
[9]   Measurement of spatial and temporal variation in volatile hazardous air pollutants in Tacoma, Washington, using a mobile membrane introduction mass spectrometry (MIMS) system [J].
Davey, Nicholas G. ;
Fitzpatrick, Cole T. E. ;
Etzkorn, Jacob M. ;
Martinsen, Morten ;
Crampton, Robert S. ;
Onstad, Gretchen D. ;
Larson, Timothy V. ;
Yost, Michael G. ;
Krogh, Erik T. ;
Gilroy, Michael ;
Himes, Kathy H. ;
Saganic, Erik T. ;
Simpson, Christopher D. ;
Gill, Christopher G. .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2014, 49 (11) :1199-1208
[10]   Membrane-introduction mass spectrometry (MIMS) [J].
Davey, Nicholas G. ;
Krogh, Erik T. ;
Gill, Chris G. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (09) :1477-1485