Comparative Evaluation of the Corneal and Anterior Chamber Parameters Derived From Scheimpflug Imaging in Arab and South Asian Normal Eyes

被引:4
作者
Prakash, Gaurav [1 ]
Srivastava, Dhruv [1 ]
Avadhani, Kavitha [2 ]
Thirumalai, Sandeep M. [3 ]
Choudhuri, Sounak [1 ,3 ]
机构
[1] New Med Ctr Specialty Hosp, NMC Eye Care, Cornea & Refract Surg Serv, Abu Dhabi, U Arab Emirates
[2] New Med Ctr Specialty Hosp, Uvea & Ocular Inflammat Serv, NMC Eye Care, Abu Dhabi, U Arab Emirates
[3] New Med Ctr Specialty Hosp, Paediat Ophthalmol Serv, NMC Eye Care, Abu Dhabi, U Arab Emirates
关键词
corneal thickness; corneal topography; anterior chamber biometrics; South Asian; Arab; ethnic comparison; OPTICAL COHERENCE TOMOGRAPHY; GENERAL PARAMETERS; SEGMENT PARAMETERS; REFRACTIVE POWER; THICKNESS; VOLUME; DEPTH; REPEATABILITY; AGREEMENT; BIOMETRY;
D O I
10.1097/ICO.0000000000000544
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To evaluate the differences in the normal corneal and anterior segment Scheimpflug parameters in Arab and South Asian eyes.Methods:This hospital-based study was performed at a cornea and refractive surgery service in Abu Dhabi. A total of 600 consecutive normal candidates of South Asian (group 1, n = 300) and Arab (group 2, n = 300) origins underwent Scheimpflug imaging (Sirius; Costruzione Strumenti Oftalmici, Italy). One eye was randomly selected for evaluation.Results:The age and sex distributions in both groups were comparable. The pachymetric variables were statistically higher in group 2 (group 2 vs. group 1, 544.3 32.2 m vs. 535.1 +/- 31.4 m for central corneal thickness, 541.0 +/- 32.6 m vs. 531.9 +/- 31.5 m for minimum corneal thickness, 571.7 +/- 43.2 m vs. 558.1 +/- 42.3 m for apical thickness, and 58.1 +/- 4.2 vs. 57.3 +/- 4.3 mm(3) for the corneal volume; P < 0.05). The anterior chamber volume (group 2 vs. group 1: 166.4 +/- 16.4 vs. 161.6 +/- 20.5 mm(3)) and angle (group 2 vs. group 1: 44.6 +/- 6.2 vs. 43.5 +/- 5.8 degrees) were also higher for group 2 (P < 0.05). Central corneal curvature and apical corneal curvature (apex K) were higher in group 1 (P < 0.05) with comparable astigmatism. The flat keratometry (K), steep K, and apex K were 43.6 +/- 2.2 diopters (D), 44.9 +/- 1.8 D, and 45.7 +/- 1.8 D for group 1, and 43.1 +/- 2.2 D, 44.5 +/- 2 D, and 45.2 +/- 1.9 D for group 2. The effect size (Cohen d) for significant parameters ranged from 0.2 to 0.3.Conclusions:Normal eyes of Arab ethnicity tend to have statistically thicker and flatter corneas and less-crowded anterior segments than those of the South Asian counterparts. These epidemiological differences have a mild to moderate biological effect size (Cohen d), but they should be considered when evaluating these eyes for anterior segment or corneal procedures.
引用
收藏
页码:1447 / 1455
页数:9
相关论文
共 50 条
[1]   The relationship between central corneal thickness and degree of myopia among Saudi adults [J].
Al-Mezaine H.S. ;
Al-Obeidan S. ;
Kangave D. ;
Sadaawy A. ;
Wehaib T.A. ;
Al-Amro S.A. .
International Ophthalmology, 2009, 29 (5) :373-378
[2]   Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing Keratoconus [J].
Ambrosio, Renato, Jr. ;
Caiado, Ana Laura C. ;
Guerra, Frederico P. ;
Louzada, Ricardo ;
Roy, Abhijit Sinha ;
Luz, Allan ;
Dupps, William J. ;
Belin, Michael W. .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :753-758
[3]   Comparison of Central Corneal Thickness, Thinnest Corneal Thickness, Anterior Chamber Depth, and Simulated Keratometry Using Galilei, Pentacam, and Sirius Devices [J].
Anayol, Mustafa A. ;
Guler, Emre ;
Yagci, Ramazan ;
Sekeroglu, Mehmet A. ;
Yilmazoglu, Meltem ;
Tirhis, Hakan ;
Kulak, Ali E. ;
Yilmazbas, Pelin .
CORNEA, 2014, 33 (06) :582-586
[4]   Anterior Segment Optical Coherence Tomography Study of the Cornea and Anterior Segment in Adult Ethnic South Asian Indian Eyes [J].
Ang, Marcus ;
Chong, Wesley ;
Tay, Wan Ting ;
Yuen, Leonard ;
Wong, Tien Yin ;
He, Ming-Guang ;
Saw, Seang Mei ;
Aung, Tin ;
Mehta, Jodhbir S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (01) :120-125
[5]  
Bamashmus MA, 2014, SAUDI MED J, V35, P56
[6]   Comparison of central corneal thickness measurements with three new optical devices and a standard ultrasonic pachymeter [J].
Bayhan, Hasan Ali ;
Bayhan, Seray Aslan ;
Can, Izzet .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (02) :302-308
[7]   Ethnic Differences of Intraocular Pressure and Central Corneal Thickness The Singapore Epidemiology of Eye Diseases Study [J].
Chua, Jacqueline ;
Tham, Yih Chung ;
Liao, Jiemin ;
Zheng, Yingfeng ;
Aung, Tin ;
Wong, Tien Yin ;
Cheng, Ching-Yu .
OPHTHALMOLOGY, 2014, 121 (10) :2013-2022
[8]  
Cohen J., 2013, Statistical power analysis for the behavioral sciences
[9]   Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers [J].
De la Parra-Colin, Paola ;
Garza-Leon, Manuel ;
Barrientos-Gutierrez, Tonatiuh .
INTERNATIONAL OPHTHALMOLOGY, 2014, 34 (01) :27-33
[10]   Pentacam Scheimpflug Evaluation of Corneal Volume After LASIK [J].
Diniz, Camila M. Gadelha P. ;
Hazarbassanov, Rossen M. ;
Yamazaki, Ester ;
Murata, Celina ;
Mallmann, Felipe ;
Campos, Mauro .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (08) :600-604