Reduced-order residential home modeling for model predictive control

被引:73
作者
Cole, Wesley J. [1 ]
Powell, Kody M. [1 ]
Hale, Elaine T. [2 ]
Edgar, Thomas F. [1 ]
机构
[1] Univ Texas Austin, Dept Chem Engn, Austin, TX 78712 USA
[2] Natl Renewable Energy Lab, Commercial Buildings Res Grp, Golden, CO 80401 USA
基金
美国国家科学基金会;
关键词
Building energy simulation; Model reduction; EnergyPlus; OpenStudio Model predictive control; Precooling; Thermal energy storage; THERMAL MASS; LOAD CONTROL; ENERGY; IDENTIFICATION; TEMPERATURE; BUILDINGS; DEMAND; REDUCTION; DESIGN; AUSTIN;
D O I
10.1016/j.enbuild.2014.01.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Building simulation softWare packages such as EnergyPlus are useful energy modeling tools. These software packages, however, are often not amenable to model-based control due to model complexity or difficulties connecting control algorithms with the software. We present a method for automatically generating input/output data from an EnergyPlus residential home model using the OpenStudio software suite. These input/output data are used to create a simple reduced-order model that can be evaluated in fractions of a second. The reduced-order model is implemented in a model predictive controller to minimize the home's electricity costs during summer months in Austin, Texas, USA. The controller optimally precools the home in the morning and turns down or off the air conditioning system in the afternoon. For this example, electricity prices were taken from actual market prices in the Austin area. The optimal precooling strategy given by the model predictive controller reduces peak energy consumption from the air conditioning unit by an average of 70% and reduces operating costs by 60%. Precooling, however, consumes more total energy versus not precooling. Reducing peak energy consumption by 1 kWh results, on average, in an increase of 0.63 kWh in overall energy consumption. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 40 条
[1]  
American Society of Heating Refrigerating Air-Conditioning Engineers, 2009, ASHRAE HDB FUND
[2]  
[Anonymous], IFAC WORLD C
[3]  
[Anonymous], 2011, AMIT DSWG WORKSH AMI
[4]   Model predictive HVAC load control in buildings using real-time electricity pricing [J].
Avci, Mesut ;
Erkoc, Murat ;
Rahmani, Amir ;
Asfour, Shihab .
ENERGY AND BUILDINGS, 2013, 60 :199-209
[5]   Parameter identification and model based predictive control of temperature inside a house [J].
Balan, Radu ;
Cooper, Joshua ;
Chao, Kuo-Ming ;
Stan, Sergiu ;
Donca, Radu .
ENERGY AND BUILDINGS, 2011, 43 (2-3) :748-758
[6]   Load control using building thermal mass [J].
Braun, JE .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (03) :292-301
[7]  
Brissette A, 2011, IEEE ENER CONV, P968, DOI 10.1109/ECCE.2011.6063877
[8]  
Cheng HK, 2008, ASHRAE TRAN, V114, P57
[9]  
Christensen C, 2006, BEOPTTM SOFTWARE BUI
[10]   BuildingLAB: A tool to analyze performance of model predictive controllers for buildings [J].
Cigler, Jiri ;
Tomasko, Pavel ;
Siroky, Jan .
ENERGY AND BUILDINGS, 2013, 57 :34-41