In Vitro Evaluation of the Gore Viabahn Balloon-Expandable Stent-Graft for Fenestrated Endovascular Aortic Repair

被引:22
|
作者
Torsello, Giovanni Federico [1 ,2 ]
Herten, Monika [2 ,3 ]
Mueller, Markus [4 ]
Andre-Frank [4 ]
Torsello, Giovanni B. [2 ]
Austermann, Martin [2 ]
机构
[1] Charite Univ Med Berlin, Charite Campus Virchow Klinikum, Dept Diagnost & Intervent Radiol & Nucl Med, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] St Franziskus Hosp Munster, Dept Vasc Surg, Munster, Germany
[3] Essen Univ Hosp, Dept Orthoped & Trauma Surg, Essen, Germany
[4] Univ Hosp Munster, Dept Hand Trauma & Reconstruct Surg, Biomech Lab, Munster, Germany
关键词
bridging stent-graft; displacement force; fenestrated stent-graft; in vitro experiment; in vitro model; material fatigue; permeability; stent fracture; ENDOGRAFTS; COMPONENTS; OUTCOMES; SECURE;
D O I
10.1177/1526602819842569
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To evaluate the safety and integrity of a new stent-graft as a potential bridging device in fenestrated stent-grafts using an in vitro fenestrated model. Materials and Methods: Polyester test sheets with ten 6-mm- or 8-mm-diameter fenestrations were used to simulate a fenestrated main body endoprosthesis. In total, 50 Viabahn balloon-expandable (VBX) stent-grafts of varying lengths (29 and 39 mm) and diameters (6, 7, and 8 mm) were implanted in the fitting fenestrations. After release, the 6- and 7-mm-diameter stent-grafts were flared with a 10x20-mm angioplasty balloon; a 12x20-mm balloon was used in the 8-mm-diameter devices. Safety of the devices was defined as absence of fractures detected on radiography or computed tomography (CT), as well as material failure detected by microscopy and water permeability testing. The forces (in Newtons, N) needed for perpendicular dislocation (pullout force) and axial dislocation (shear stress force) were also evaluated. Results: Forty VBX stent-grafts were subjected to digital radiographic imaging and multiplanar CT. None showed any stent fracture. Subsequent microscopy indicated no damage to the fabric or separation of the graft after flaring. Ten VBX stent-grafts underwent water permeability testing after flaring; no water passed through the graft wall during a 10-minute period under an intraluminal pressure at 120 mm Hg. Testing of 25 VBX stent-grafts revealed initial pullout forces between 11.3 and 31 N. Shear stress tests showed that the average force needed to dislocate the stent-grafts by 50% of their diameter ranged between 5.75 and 6.91 N (mean 6.1 +/- 0.5 N) for the 6-mm stents and between 3.31 and 5.4 N (mean 4.4 +/- 0.8) for the 8-mm stents. Conclusion: This preliminary study demonstrated the applicability of the VBX as a bridging stent-graft in a simulated fenestration model. A comparison with other stent-grafts and clinical assessment are required.
引用
收藏
页码:361 / 368
页数:8
相关论文
共 50 条
  • [41] Comparison of BARD®LIFESTREAM™ covered balloon-expandable stent versus GORE® VIABAHN™ covered self-expandable stent in treatment of aortoiliac obstructive disease: study protocol for a prospective randomized controlled trial (NEONATAL trial)
    Qi, Yuhan
    Wang, Jiarong
    Zhao, Jichun
    Huang, Bing
    Xiong, Fei
    Du, Xiaojiong
    Chen, Xiyang
    Guo, Qiang
    Wang, Tiehao
    Yuan, Ding
    TRIALS, 2022, 23 (01)
  • [42] Three-Dimensional Geometric Analysis of Balloon-Expandable Covered Stents Improves Classification of Complications after Fenestrated Endovascular Aneurysm Repair
    van der Riet, Claire
    Schuurmann, Richte C. L.
    Verhoeven, Eric L. G.
    Katsargyris, Athanasios
    Tielliu, Ignace F. J.
    Resch, Timothy
    Bokkers, Reinoud P. H.
    De Vries, Jean-Paul P. M.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (19)
  • [43] Fenestrated stent-graft repair: Which stent should be used to secure target vessel fenestrations?
    Scurr, James R. H.
    How, Thien V.
    McWilliams, Richard G.
    Lane, Steven
    Gilling-Smith, Geoffrey L.
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (03) : 344 - 348
  • [44] Use of a Molding Balloon to Facilitate Introduction of Guiding Catheters in Fenestrated Stent-Graft Procedures
    Bicknell, Colin
    Riga, Celia
    Mireskandari, Maziar
    Haulon, Stephan
    Hamady, Mohamad
    Jenkins, Michael
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (05) : 514 - 517
  • [45] Outcomes of bridging stent grafts in fenestrated and branched endovascular aortic repair
    Torsello, Giovanni Federico
    Beropoulis, Efthymios
    Munao, Roberta
    Trimarchi, Santi
    Torsello, Giovanni B.
    Austermann, Martin
    JOURNAL OF VASCULAR SURGERY, 2020, 72 (03) : 859 - 865
  • [46] Endovascular Reintervention for Stent-Graft Dislocation after Open Surgical Conversion for Thoracoabdominal Aortic Aneurysm Treated by Thoracic Endovascular Aortic Repair
    Nakatsu, Tomoki
    Kikuchi, Shinsuke
    Miyamoto, Hiroyuki
    Kimura, Fumiaki
    VASCULAR SPECIALIST INTERNATIONAL, 2022, 38
  • [47] Performance of BeGraft and BeGraft plus Stent-Grafts as Bridging Devices for Fenestrated Endovascular Aneurysm Repair: An In Vitro Study
    Torsello, Giovanni Federico
    Herten, Monika
    Frank, Andre
    Mueller, Markus
    Jung, Susanne
    Torsello, Giovanni B.
    Austermann, Martin
    JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (06) : 787 - 794
  • [48] Early Results of Elective Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms With the Minos™Stent-Graft System
    Pitoulias, Georgios A.
    Pitoulias, Apostolos G.
    Chatzelas, Dimitrios A.
    Zampaka, Theodosia
    Loutradis, Charalampos
    Potouridis, Anastasios
    Tachtsi, Maria D.
    JOURNAL OF ENDOVASCULAR THERAPY, 2025, 32 (01) : 225 - 232
  • [49] Endovascular Aneurysm Repair with Zenith Alpha Abdominal Stent-Graft in Hostile and Nonhostile Aortic Neck Anatomies
    Bertagna, Giulia
    Troisi, Nicola
    Pulli, Raffaele
    de Donato, Gianmarco
    Pierozzi, Sofia
    Artini, Valerio
    Berchiolli, Raffaella
    ANNALS OF VASCULAR SURGERY, 2025, 116 : 81 - 91
  • [50] Case report: Endovascular stent-graft repair of aortic penetrating trauma, literature review, and case report
    Bayona, Juan Gabriel
    Chaves, Carlos Eduardo Rey
    Rodriguez, Oscar Geovanny Hernandez
    Baron, Vladimir
    Fajardo, Ernesto
    Posada, Eduardo
    FRONTIERS IN SURGERY, 2023, 10