In Vitro Evaluation of the Gore Viabahn Balloon-Expandable Stent-Graft for Fenestrated Endovascular Aortic Repair

被引:22
|
作者
Torsello, Giovanni Federico [1 ,2 ]
Herten, Monika [2 ,3 ]
Mueller, Markus [4 ]
Andre-Frank [4 ]
Torsello, Giovanni B. [2 ]
Austermann, Martin [2 ]
机构
[1] Charite Univ Med Berlin, Charite Campus Virchow Klinikum, Dept Diagnost & Intervent Radiol & Nucl Med, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] St Franziskus Hosp Munster, Dept Vasc Surg, Munster, Germany
[3] Essen Univ Hosp, Dept Orthoped & Trauma Surg, Essen, Germany
[4] Univ Hosp Munster, Dept Hand Trauma & Reconstruct Surg, Biomech Lab, Munster, Germany
关键词
bridging stent-graft; displacement force; fenestrated stent-graft; in vitro experiment; in vitro model; material fatigue; permeability; stent fracture; ENDOGRAFTS; COMPONENTS; OUTCOMES; SECURE;
D O I
10.1177/1526602819842569
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To evaluate the safety and integrity of a new stent-graft as a potential bridging device in fenestrated stent-grafts using an in vitro fenestrated model. Materials and Methods: Polyester test sheets with ten 6-mm- or 8-mm-diameter fenestrations were used to simulate a fenestrated main body endoprosthesis. In total, 50 Viabahn balloon-expandable (VBX) stent-grafts of varying lengths (29 and 39 mm) and diameters (6, 7, and 8 mm) were implanted in the fitting fenestrations. After release, the 6- and 7-mm-diameter stent-grafts were flared with a 10x20-mm angioplasty balloon; a 12x20-mm balloon was used in the 8-mm-diameter devices. Safety of the devices was defined as absence of fractures detected on radiography or computed tomography (CT), as well as material failure detected by microscopy and water permeability testing. The forces (in Newtons, N) needed for perpendicular dislocation (pullout force) and axial dislocation (shear stress force) were also evaluated. Results: Forty VBX stent-grafts were subjected to digital radiographic imaging and multiplanar CT. None showed any stent fracture. Subsequent microscopy indicated no damage to the fabric or separation of the graft after flaring. Ten VBX stent-grafts underwent water permeability testing after flaring; no water passed through the graft wall during a 10-minute period under an intraluminal pressure at 120 mm Hg. Testing of 25 VBX stent-grafts revealed initial pullout forces between 11.3 and 31 N. Shear stress tests showed that the average force needed to dislocate the stent-grafts by 50% of their diameter ranged between 5.75 and 6.91 N (mean 6.1 +/- 0.5 N) for the 6-mm stents and between 3.31 and 5.4 N (mean 4.4 +/- 0.8) for the 8-mm stents. Conclusion: This preliminary study demonstrated the applicability of the VBX as a bridging stent-graft in a simulated fenestration model. A comparison with other stent-grafts and clinical assessment are required.
引用
收藏
页码:361 / 368
页数:8
相关论文
共 50 条
  • [31] Operative and Midterm Outcomes of the Fenestrated Anaconda Stent-Graft in the Endovascular Treatment of Juxtarenal, Suprarenal, and Type IV Thoracoabdominal Aortic Aneurysms
    Kotelis, Drosos
    Schleimer, Karina
    Foldenauer, Christina
    Jalaie, Houman
    Grommes, Jochen
    Jacobs, Michael J.
    Kalder, Johannes
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (06) : 930 - 935
  • [32] Anatomical suitability for branched endovascular aortic arch repair and balloon-expandable bridging stent grafts in a cohort of patients previously treated with a hybrid approach
    Leone, Nicola
    Bartolotti, Luigi Alberto Maria
    Baresi, Giovanni Francesco
    Silingardi, Roberto
    Resch, Timothy Andrew
    Gennai, Stefano
    JOURNAL OF VASCULAR SURGERY, 2024, 79 (02)
  • [33] Iliac conduit for renal and visceral artery access during endovascular repair of a pararenal aneurysm with a fenestrated stent-graft
    Batt, Michel
    Haulon, Stephan
    Bouillanne, Pierre-Jean
    Baque, Jean
    Fassbender, Verena
    Haudebourg, Pierre
    Hassen-Khodja, Reda
    Jean-Baptiste, Elixene
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (03) : 416 - 420
  • [34] Predicting Features of Visceral Stent Failure in Fenestrated Endovascular Aortic Aneurysm Repair
    Mancuso, Enrico
    Bootun, Roshan
    Stather, Philip W.
    Crawford, Michael
    Delbridge, Michael
    Ali, Mohammad Tariq
    Al-Jundi, Wissam
    JOURNAL OF ENDOVASCULAR THERAPY, 2025, 32 (02) : 389 - 397
  • [35] Successful recovery from transcatheter aortic valve embolization by thoracic endovascular stent-graft repair
    Ueno, Go
    Ohno, Nobuhisa
    Toma, Masanao
    Kobayashi, Taishi
    Maeda, Toshi
    Kato, Otohime
    Yoshizawa, Kosuke
    Miyamoto, Tadashi
    Fujiwara, Keiichi
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2020, 68 (08) : 851 - 854
  • [36] Preliminary results of the Austrian National Registry regarding the novel iCover bridging stent graft in fenestrated endovascular aortic repair
    Hauck, Sven R.
    Dachs, Theresa-Marie
    Kern, Maximilian
    Eilenberg, Wolf
    Mueller-Wille, Rene
    Fezoulidis, Nicolas
    Hausegger, Klaus
    Heurteur, Georg
    Gschwendtner, Manfred
    Neumayer, Christoph
    Loewe, Christian
    Funovics, Martin A.
    ASIAN JOURNAL OF SURGERY, 2024, 47 (09) : 3858 - 3863
  • [37] Technical aspects of repair of juxtarenal abdominal aortic aneurysms using the Zenith fenestrated endovascular stent graft
    Oderich, Gustavo S.
    Correa, Mateus P.
    Mendes, Bernardo C.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (05) : 1456 - 1461
  • [38] The "fenestrated inside fenestrated" stent graft solution for therapy-resistant type Ia endoleak after fenestrated endovascular aortic aneurysm repair
    Ritter, Jens C.
    Stanley, Brendan M.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (03) : 814 - 816
  • [39] Technical Assessment of the Preloaded Fenestrated Stent-Graft in the Management of Pararenal Aortic Aneurysms
    Bisdas, Theodosios
    Donas, Konstantinos P.
    Torsello, Giovanni
    Austermann, Martin
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 461 - 468
  • [40] Advances in fenestrated and branch stent-graft technology and current applications in patients with complex aortic aneurysms
    Oderich, G. S.
    Ricotta, J. J., II
    ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 16 (04): : 265 - 279