Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

被引:8
作者
Mahdavi, S. R. [1 ]
Gharehbagh, E. Jazayeri [2 ]
Mofid, B. [3 ]
Jafari, A. H. [4 ]
Nikoofar, A. R. [5 ]
机构
[1] Iran Univ Med Sci, Dept Med Phys, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Allied Hlth Sci, Dept Radiol & Radiotherapy Technol, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Dept Radiotherapy, Tehran, Iran
[4] Tehran Univ Medial Sci, Res Ctr Biomed Technol & Robot, Tehran, Iran
[5] Iran Univ Med Sci, Dept Radiotherapy, Tehran, Iran
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2017年 / 15卷 / 01期
关键词
Prostate cancer; EPID; systematic errors; random errors; RADIOPAQUE MARKERS; ORGAN MOTION; TREATMENT VERIFICATION; STANDARD RADIOTHERAPY; ROUTINE RADIOTHERAPY; GUIDED RADIOTHERAPY; PELVIC RADIOTHERAPY; IRRADIATION; POSITION; LOCALIZATION;
D O I
10.18869/acadpub.ijrr.15.1.39
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The plan was prepared in accordance with ICRU 50 guidance (PTV to receive 95-107% dose). The software program reconstructed the three-dimensional position of the markers from the different Beams Eye Views (BEV). The discrepancies of the seeds' positions (prostate surrogate) between plan and daily images were calculated three dimensionally. Then, necessary corrections were applied to match the prostate fiducial markers in the portal image with the BEV image in the planned one by moving the couch in the X, Y and Z directions. Results: Data from 15 patients and 469 fractions of radiotherapy were analyzed in this study. Two sets of data were available from EPID software before and after 3D set-up corrections. The mean of the population displacement in Left /Right (L/R), Anterior/Posterior (A/P) and Crania/Caudal (C/C) directions were 0.5,-1.0 and 2.4mm before, and-0.1,-0.5 and 0.9mm after corrections, respectively. The systematic and random errors for the measured populations in the three mentioned directions were 2.4, 2.7 and 2mm and 6.4, 5.9 and 6.1mm before corrections, and 1.1, 2.4 and 1.4mm and 3.8, 3.9 and 3.6mm after corrections, correspondingly. Conclusion: This study provides further evidence that using gold markers in the prostate improves dose delivery to the prostate. Also, it has been demonstrated that the EPID can be a powerful tool in the reduction of treatment setup errors and the quality assurance and verification of complex treatments.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 34 条
[1]   Prostate target volume variations during a course of radiotherapy [J].
Antolak, JA ;
Rosen, II ;
Childress, CH ;
Zagars, GK ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :661-672
[2]   Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research [J].
Antonuk, LE .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (06) :R31-R65
[3]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[4]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[5]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[6]   PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS [J].
CROOK, JM ;
RAYMOND, Y ;
SALHANI, D ;
YANG, H ;
ESCHE, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :35-42
[7]   Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy [J].
De Crevoisier, R ;
Tucker, SL ;
Dong, L ;
Mohan, R ;
Cheung, R ;
Cox, JD ;
Kuban, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :965-973
[8]   CONFORMAL ARC RADIOTHERAPY FOR PROSTATE CANCER: INCREASED BIOCHEMICAL FAILURE IN PATIENTS WITH DISTENDED RECTUM ON THE PLANNING COMPUTED TOMOGRAM DESPITE IMAGE GUIDANCE BY IMPLANTED MARKERS [J].
Engels, Benedikt ;
Soete, Guy ;
Verellen, D. ;
Storme, Guy .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02) :388-391
[9]   REPRODUCIBILITY OF PATIENT POSITIONING DURING ROUTINE RADIOTHERAPY, AS ASSESSED BY AN INTEGRATED MEGAVOLTAGE IMAGING-SYSTEM [J].
GILDERSLEVE, J ;
DEARNALEY, DP ;
EVANS, PM ;
SWINDELL, W .
RADIOTHERAPY AND ONCOLOGY, 1995, 35 (02) :151-160
[10]  
Herman M G, 2000, J Appl Clin Med Phys, V1, P38, DOI 10.1120/1.308249