Hearing aid fitting and developmental outcomes of children fit according to either the NAL or DSL prescription: fit-to-target, audibility, speech and language abilities

被引:9
作者
Ching, Teresa Y. C. [1 ,2 ]
Zhang, Vicky W. [1 ,2 ]
Johnson, Earl E. [3 ,4 ]
Van Buynder, Patricia [1 ,2 ]
Hou, Sanna [1 ,2 ]
Burns, Lauren [1 ,2 ]
Button, Laura [1 ,2 ]
Flynn, Christopher [1 ,5 ]
McGhie, Karen [1 ,6 ]
机构
[1] Natl Acoust Labs, Sydney, NSW, Australia
[2] HEARing CRC, Melbourne, Vic, Australia
[3] James H Quillen VA Med Ctr, Mountain Home, TN USA
[4] East Tennessee State Univ, Dept Audiol & Speech Language Pathol, Johnson City, TN 37614 USA
[5] Australian Hearing, Brisbane, Qld, Australia
[6] Australian Hearing, Mt Gravatt, Qld, Australia
关键词
Children; hearing loss; hearing aids; hearing-aid prescription; audibility; outcomes; PEDIATRIC AMPLIFICATION; INTELLIGIBILITY INDEX; FREQUENCY RESPONSES; RECOGNITION; PERFORMANCE; PROTOCOL; NAL-NL1; PREDICTIONS; PERCEPTION; LOUDNESS;
D O I
10.1080/14992027.2017.1380851
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: This study examined the influence of prescription on hearing aid (HA) fitting characteristics and 5-year developmental outcomes of children. Design: A randomised controlled trial implemented as part of a population-based study on Longitudinal Outcomes of Children with Hearing Impairment (LOCHI). Study sample: Two-hundred and thirty-two children that were fit according to either the National Acoustic Laboratories (NAL) or Desired Sensation Level (DSL) prescription. Results: Deviation from targets and root-mean-square error in HA fitting revealed no significant difference between fitting prescriptions. Aided audibility quantified by using the Speech Intelligibility Index (SII) model showed that DSL provided higher audibility than NAL at low and medium input levels but not at high input level. After allowing for hearing loss desensitisation, differences in audibility between prescription groups were significant only at low input level. The randomised trial of prescription that was implemented for 163 children revealed no significant between-group differences in speech production, perception, and language; but parent-rated functional performance was higher for the DSL than for the NAL group. Conclusions: Proximity to prescriptive targets was similar between fitting prescriptions. The randomised trial revealed differences in aided audibility at low input level between prescription groups, but no significant differences in speech and language abilities.
引用
收藏
页码:S41 / S54
页数:14
相关论文
共 52 条
  • [1] Comparsion of three procedures for initial fitting of compression hearing aids.: II.: Experienced users, fitted unilaterally
    Alcántara, JI
    Moore, BCJ
    Marriage, J
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2004, 43 (01) : 3 - 14
  • [2] American Academy of Audiology Task Force on Pediatric Amplification, 2013, AM AC AUD CLIN PRACT
  • [3] American National Standards Institute (ANSI), 1997, METHODS CALCULATION
  • [4] [Anonymous], 2011, AUDIOLOGY RES
  • [5] [Anonymous], 2007, PPVT 4 PEABODY PICTU
  • [6] [Anonymous], 2007, SPSS for Windows, Version 17
  • [7] Prescribing and Verifying Hearing Aids Applying the American Academy of Audiology Pediatric Amplification Guideline: Protocols and Outcomes from the Ontario Infant Hearing Program
    Bagatto, Marlene
    Moodie, Sheila
    Brown, Christine
    Malandrino, April
    Richert, Frances
    Clench, Debbie
    Scollie, Susan
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2016, 27 (03) : 188 - 203
  • [8] Protocol for the provision of amplification within the Ontario Infant hearing program
    Bagatto, Marlene
    Scollie, Susan D.
    Hyde, Martyn
    Seewald, Richard
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2010, 49 : S70 - S79
  • [9] Bagatto MP, 2011, TRENDS AMPLIF, V15, P57, DOI 10.1177/1084713811420304
  • [10] Factors affecting the use and perceived benefit of ITE and BTE hearing aids
    Baumfield, A
    Dillon, H
    [J]. BRITISH JOURNAL OF AUDIOLOGY, 2001, 35 (04): : 247 - 258