Pulmonary delivery of deslorelin:: Large-porous PLGA particles and HPβCD complexes

被引:59
作者
Koushik, K [1 ]
Dhanda, DS [1 ]
Cheruvu, NPS [1 ]
Kompella, UB [1 ]
机构
[1] Univ Nebraska, Med Ctr, Dept Pharmaceut Sci, Omaha, NE 68105 USA
关键词
deslorelin; HP beta CD; intratracheal; large-porous particles; PLGA;
D O I
10.1023/B:PHAM.0000032997.96823.88
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose. To compare the systemic delivery of deslorelin following intratracheal administration of different deslorelin formulations. The formulations included dry powders of deslorelin, large-porous deslorelinpoly-(lactide-co-glycolide) (PLGA) particles, and small conventional deslorelin-PLGA particles. Also, solution formulations of deslorelin and deslorelin-hydroxy-propyl-beta-cyclodextrin (HPbetaCD) complexes were tested. Methods. Dry powders of deslorelin, large-porous (mean diameter, 13.8 mum; density, 0.082 g/cc), and small conventional (mean diameter, 2.2 mum; density, 0.7 g/cc) deslorelin-PLGA particles and solutions of deslorelin with or without HPbetaCD were administered intratracheally to Sprague-Dawley rats. Blood samples were collected at 3 h, 1, 3, and 7 days postdosing, and plasma deslorelin concentrations were determined using enzyme immunoassay. At the end of 7 days, lungs were isolated, and bronchoalveolar lavage fluid was collected and analyzed for deslorelin. Results. At the end of 7 days, deslorelin plasma concentrations in the large-porous deslorelin-PLGA particle group were 120-fold and 2.5-fold higher compared to deslorelin powder and small conventional deslorelin-PLGA particles, respectively. Co-administration of HPbetaCD resulted in 2-, 3-, and 3- fold higher plasma deslorelin concentrations at 3 h, 1 and 3 days, respectively, compared to deslorelin solution. On day 7, deslorelin concentrations in bronchoalveolar lavage fluid as well as plasma were in the order: large porous particles > small conventional particles > deslorelin-HPbetaCD solution > deslorelin powder > deslorelin solution. Conclusions. Large-porous deslorelin PLGA particles can sustain deslorelin delivery via the deep lungs. Co-administration of HPbetaCD enhances the systemic delivery of deslorelin. The pulmonary route is useful as a noninvasive alternative for the systemic delivery of deslorelin.
引用
收藏
页码:1119 / 1126
页数:8
相关论文
共 41 条
[1]  
ADJEIAND A, 1997, INHALATION DELIVERY
[2]  
Agu RU, 2001, RESP RES, V2, P198
[3]   Modifying the release of leuprolide from spray dried OED microparticles [J].
Alcock, R ;
Blair, JA ;
O'Mahony, DJ ;
Raoof, A ;
Quirk, AV .
JOURNAL OF CONTROLLED RELEASE, 2002, 82 (2-3) :429-440
[4]   Biodegradation and biocompatibility of PLA and PLGA microspheres [J].
Anderson, JM ;
Shive, MS .
ADVANCED DRUG DELIVERY REVIEWS, 1997, 28 (01) :5-24
[5]   Large porous particles for sustained protection from carbachol-induced bronchoconstriction in guinea pigs [J].
Ben-Jebria, A ;
Chen, DH ;
Eskew, ML ;
Vanbever, R ;
Langer, R ;
Edwards, DA .
PHARMACEUTICAL RESEARCH, 1999, 16 (04) :555-561
[6]   Fundamental effects of particle morphology on lung delivery: Predictions of Stokes' law and the particular relevance to dry powder inhaler formulation and development [J].
Crowder, TM ;
Rosati, JA ;
Schroeter, JD ;
Hickey, AJ ;
Martonen, TB .
PHARMACEUTICAL RESEARCH, 2002, 19 (03) :239-245
[7]   Recent advances in the diagnosis and treatment of precocious puberty [J].
Alejandro Diaz ;
Macro Danon .
The Indian Journal of Pediatrics, 2000, 67 (3) :211-215
[8]   Improved lung delivery from a passive dry powder inhaler using an engineered PulmoSphere® powder [J].
Duddu, SP ;
Sisk, SA ;
Walter, YH ;
Tarara, TE ;
Trimble, KR ;
Clark, AR ;
Eldon, MA ;
Elton, RC ;
Pickford, M ;
Hirst, PH ;
Newman, SP ;
Weers, JG .
PHARMACEUTICAL RESEARCH, 2002, 19 (05) :689-695
[9]   In vitro and in vivo dose delivery characteristics of large porous particles for inhalation [J].
Dunbar, C ;
Scheuch, G ;
Sommerer, K ;
DeLong, M ;
Verma, A ;
Batycky, R .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 245 (1-2) :179-189
[10]   Bioengineeiring of therapeutic aerosols [J].
Edwards, DA ;
Dunbar, C .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2002, 4 :93-107