An Improved Sensitive and Selective Non-enzymatic Glucose Biosensor Based on PEG Assisted CuO Nanocomposites

被引:7
作者
Azharudeen, A. Mohamed [1 ]
Suriyakala, T. [1 ]
Rajarajan, M. [2 ]
Suganthi, A. [3 ]
机构
[1] CPA Coll, PG & Res Dept Chem, Bbodinayakanur 625513, Tamil Nadu, India
[2] Madurai Kamaraj Univ, Directorate Distance Educ, Madurai 625021, Tamil Nadu, India
[3] Mother Teresa Womens Univ, Kodaikanal 624102, Tamil Nadu, India
来源
EGYPTIAN JOURNAL OF CHEMISTRY | 2019年 / 62卷 / 03期
关键词
CuO; Mesoporous; PEG; Glucose; Biosensor; ELECTROCHEMICAL DETECTION; SENSOR; NANOPARTICLES; NANOSTRUCTURES; NANOMATERIALS; NANOTUBES; TEMPLATE;
D O I
10.21608/EJCHEM.2018.5707.1489
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
DETERMINATION of glucose is of enormous importance in the fields of biological, environmental and clinical analyses. In recent years, polymer modified metal oxides arrived a great consideration in the detection of glucose. In this study, we have developed a sensitive and selective non-enzymatic glucose sensor by using CuO NMO encapsulation with PEG (poly ethyleneglycol) nanocomposites. The loading content of PEG was incorporated with CuO by weight percentage (wt = 2, 4 & 6%). The fabricated CuO/PEG nanocomposites were utilized as a glucose sensor, it exhibits the tremendous electrocatalytic performances on oxidation of glucose. The electrocatalytic activity enhances with increasing the loading of PEG content. The sensor shows a low detection limit of 0.25 mu M with a sensitivity of 113.8 mu A mM(-1) cm(-2), good selectivity and stability. The CuO/PEG nanocomposites are hopeful for the advancement of cost-effective non-enzymatic glucose biosensors.
引用
收藏
页码:487 / 500
页数:14
相关论文
共 36 条
[1]   Polymers in sensor applications [J].
Adhikari, B ;
Majumdar, S .
PROGRESS IN POLYMER SCIENCE, 2004, 29 (07) :699-766
[2]   Potentiometric ion sensors based on conducting polymers [J].
Bobacka, J ;
Ivaska, A ;
Lewenstam, A .
ELECTROANALYSIS, 2003, 15 (5-6) :366-374
[3]   Nanomaterials based electrochemical sensors for biomedical applications [J].
Chen, Aicheng ;
Chatterjee, Sanghamitra .
CHEMICAL SOCIETY REVIEWS, 2013, 42 (12) :5425-5438
[4]   Templated synthesis of CdS/PAN composite nanowires under ambient conditions [J].
Chen, M ;
Xie, Y ;
Chen, HY ;
Qiao, ZP ;
Zhu, YJ ;
Qian, YT .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2000, 229 (01) :217-221
[5]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[6]   Influence of polyethylene glycol template on microstructure and electrochromic properties of tungsten oxide [J].
Deepa, M. ;
Kar, M. ;
Singh, D. P. ;
Srivastava, A. K. ;
Ahmad, Shahzada .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2008, 92 (02) :170-178
[7]   A new non-enzymatic glucose sensor based on copper/porous silicon nanocomposite [J].
Ensafi, Ali A. ;
Abarghoui, M. Mokhtari ;
Rezaei, B. .
ELECTROCHIMICA ACTA, 2014, 123 :219-226
[8]   Fabrication and characterization of non-enzymatic glucose sensor based on ternary NiO/CuO/polyaniline nanocomposite [J].
Ghanbari, Kh. ;
Babaei, Z. .
ANALYTICAL BIOCHEMISTRY, 2016, 498 :37-46
[9]   Synthesis and characterization of doxorubicin modified ZnO/PEG nanomaterials and its photodynamic action [J].
Hariharan, R. ;
Senthilkumar, S. ;
Suganthi, A. ;
Rajarajan, M. .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2012, 116 :56-65
[10]  
Hariharan R., 2005, MAT RES B, V94, P454