Intraocular lens formula comparison in axial hyperopia with a high-power intraocular lens of 30 or more diopters

被引:54
作者
Kane, Jack X. [1 ]
Melles, Ronald B. [2 ]
机构
[1] Royal Victorian Eye & Ear Hosp, Melbourne, Vic, Australia
[2] Redwood City Med Ctr, Permanent Med Grp, Redwood City, CA USA
关键词
HOFFER-Q; ACCURACY; EYES; BIOMETRY; SRK/T;
D O I
10.1097/j.jcrs.0000000000000235
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formula predictions (Barrett Universal II, Emmetropia Verifying Optical [EVO] 2.0, Haigis, Hill-RBF 2.0, Holladay 1, Holladay 2, Hoffer Q, Kane, Olsen, and SRK/T) when using the Alcon SA60AT IOL of 30 or greater diopter (D) power. Setting: Kaiser Permanente, California, USA. Design: Multicenter retrospective consecutive case series. Methods: Data from patients having uneventful cataract surgery with insertion of a >= 30 D SA60AT IOL and preoperative LENSTAR 900 biometry were included. A single eye per qualifying patient was randomly selected for inclusion in the analysis. Lens constants were optimized using a large dataset of the same IOLmodel including the full range of axial lengths. The optimized lens constants were then used to calculate the predicted refraction for each formula, which was compared with the actual refractive outcome to give the prediction errors. Results: Included in the study were 182 eyes of 182 patients. From highest to lowest, the percentage of eyes with a prediction error within +/- 0.50 D was the Kane (58.8%), EVO 2.0 (57.7%), Haigis (55.5%), Holladay 2 (54.9%), Olsen (53.3%), Holladay 1 (50.5%), Hill-RBF 2.0 (43.9%), SRK/ T (42.9%), Barrett Universal II (36.8%), and Hoffer Q (35.7%) formulas. The Kane formula had a statistically significant lower mean absolute prediction error compared with all formulas (P <.05) except the EVO 2.0 formula. Conclusions: The Kane formula had the lowest prediction error of the formulas studied, which was statistically significant compared with all formulas except the EVO 2.0 formula. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:1236 / 1239
页数:4
相关论文
共 15 条
[1]   Statistical Analysis for Studies of Intraocular Lens Formula Accuracy [J].
Aristodemou, Petros ;
Cartwright, Nathaniel E. Knox ;
Sparrow, John M. ;
Johnston, Robert L. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (05) :1085-1086
[2]   Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry [J].
Aristodemou, Petros ;
Cartwright, Nathaniel E. Knox ;
Sparrow, John M. ;
Johnston, Robert L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) :63-71
[3]   Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service [J].
Darcy, Kieren ;
Gunn, David ;
Tavassoli, Shokufeh ;
Sparrow, John ;
Kane, Jack X. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01) :2-7
[4]   Intraocular lens power calculations in short eyes using 7 formulas [J].
Gokce, Sabite E. ;
Zeiter, John H. ;
Weikert, Mitchell P. ;
Koch, Douglas D. ;
Hill, Warren ;
Wang, Li .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (07) :892-897
[5]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[6]  
Hoffer Kenneth J, 2017, Int Ophthalmol Clin, V57, P137, DOI 10.1097/IIO.0000000000000180
[7]   Protocols for Studies of Intraocular Lens Formula Accuracy [J].
Hoffer, Kenneth J. ;
Aramberri, Jaime ;
Haigis, Wolfgang ;
Olsen, Thomas ;
Savini, Giacomo ;
Shammas, H. John ;
Bentow, Stanley .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (03) :403-405
[9]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24
[10]   Update on Intraocular Lens Calculation Formulas [J].
Melles, Ronald B. ;
Kane, Jack X. ;
Olsen, Thomas ;
Chang, William J. .
OPHTHALMOLOGY, 2019, 126 (09) :1334-1335