KINEMATICS, ERROR ANALYSIS, AND COMPENSATION OF A HIGH PRECISION TENDON-BASED MRI-COMPATIBLE ROBOT

被引:2
|
作者
Jiang, Shan [1 ]
Sun, Fude [1 ]
Lou, Jinlong [1 ]
Yang, Zhiyong [1 ]
机构
[1] Tianjin Univ, Sch Mech Engn, Minist Educ, Key Lab Mech & Equipment Design, Tianjin 300072, Peoples R China
来源
关键词
MRI-compatible robot; kinematic analysis; tendon-based transmission; error analysis; WORKSPACE ANALYSIS; PARALLEL; DESIGN; MANIPULATOR; CALIBRATION; SYSTEM; MODEL;
D O I
10.2316/Journal.206.2015.4.206-4184
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, a high precision tendon-based magnetic resonance imaging-compatible robot for prostate needle-insertion surgery is introduced briefly, which is possessed of five degrees of freedom. What follows is the kinematic analysis together with the Jacobian analysis. Based on the forward kinematics, the reachable workspace of the robot is then calculated. The main contribution of this paper, an error model of the robot considering the input errors, form and position errors of the revolute joints, and main parts of the manipulator is then established. To obtain the backlash associated with the tendon-based transmission system, the statics analysis is conducted. Given a series of certain values of the error source mentioned above and a certain trajectory of the surgical needle tip, which is based on kinematics in the reachable workspace, the comparative result of the trajectory based on the error model is obtained. Finally, the experiment is conducted to verify the veracity of the error model.
引用
收藏
页码:333 / 344
页数:12
相关论文
共 50 条
  • [1] Design and analysis of a tendon-based MRI-compatible surgery robot for transperineal prostate needle placement
    Jiang, Shan
    Sun, Fude
    Dai, Jiansheng
    Liu, Jun
    Yang, Zhiyong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2015, 229 (02) : 335 - 348
  • [2] Modeling and control of a high-precision tendon-based magnetic resonance imaging-compatible surgical robot
    Jiang, Shan
    Lou, Jinlong
    Sun, Fude
    Yang, Zhiyong
    Dai, Jiansheng
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART I-JOURNAL OF SYSTEMS AND CONTROL ENGINEERING, 2015, 229 (08) : 711 - 727
  • [3] Design and Analysis of A Novel MRI-compatible Breast Biopsy Robot
    Lu, Mingyue
    Zhang, Yongde
    Hu, Zhaoli
    Du, Haiyan
    Niu, Suoliang
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2018, : 1238 - 1243
  • [4] Vibration Analysis of Tendon-based Parallel Robot for Processing
    Tang, Aofei
    Li, Yan
    Kong, Lingfei
    Cheng, Xiaojuan
    ENGINEERING SOLUTIONS FOR MANUFACTURING PROCESSES, PTS 1-3, 2013, 655-657 : 1086 - 1091
  • [5] Towards the Development of a SMA-Actuated MRI-Compatible Tendon-Driven Neurosurgical Robot
    Ho, Mingyen
    Desai, Jaydev P.
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2012, : 683 - 688
  • [6] Design and analysis of a tendon-based computed tomography-compatible robot with remote center of motion for lung biopsy
    Yang, Yunpeng
    Jiang, Shan
    Yang, Zhiyong
    Yuan, Wei
    Dou, Huaisu
    Wang, Wei
    Zhang, Daguang
    Bian, Yuan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (04) : 286 - 298
  • [7] High-Precision MRI-Compatible Force Sensor with Parallel Plate Structure
    Tokuno, Takashi
    Tada, Mitsunori
    Umeda, Kazunori
    2008 2ND IEEE RAS & EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB 2008), VOLS 1 AND 2, 2008, : 33 - +
  • [8] High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions
    Su, Hao
    Camilo, Alex
    Cole, Gregory A.
    Hata, Nobuhiko
    Tempany, Clare M.
    Fischer, Gregory S.
    MEDICINE MEETS VIRTUAL REALITY 18, 2011, 163 : 623 - 629
  • [9] A MRI-compatible stereotaxic localizer box enables high-precision stereotaxic procedures in pigs
    Bjarkam, CR
    Cancian, G
    Larsen, M
    Rosendahl, F
    Ettrup, KS
    Zeidler, D
    Blankholm, AD
    Ostergaard, L
    Sunde, N
    Sorensen, JC
    JOURNAL OF NEUROSCIENCE METHODS, 2004, 139 (02) : 293 - 298
  • [10] Error Compensation Method for High Precision Microsurgical Robot with RCM Manipulator
    Bai M.
    Zhang M.
    Zhang H.
    Pang L.
    Zhao J.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2022, 58 (18): : 170 - 180