Investigation of the "block effect" on spatial resolution in PET detectors

被引:0
作者
Tomic, N [1 ]
Thompson, CJ [1 ]
Casey, ME [1 ]
机构
[1] McGill Univ, Dept Med Phys, Montreal, PQ HRA 2B4, Canada
来源
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Previous studies suggest that when block detectors are used in positron emission tomography (PET) scanners, a "block effect" of about 2 mm can be added in quadrature to the other effects blurring spatial resolution (SR). However, no explanation of the cause of the effect has ever been published. We studied the origin of the "block effect", using experiments in which all other blurring effects on SR were minimized and precisely determined. Thin (1 mm) bismuth germanate (BGO) crystals and a small (1 mm) 68Ge source were used to probe the SR of a CTI HR+ block detector and two precise translation stages to move detectors. We compared coincidence aperture functions (CAFs) for crystals in the block with CAFs of sing e crystals of various widths. From those measurements, done wit one block detector, we concluded that the central crystals in the block showed an additional blurring of 0.8 mm whereas the edge ones showed no additional blurring. The obtained full width at half maximum (FWHM) for central crystals was found to be 2.20 +/- 0.05 mm and for edge crystals 1.98 +/- 0.03 mm. The FWHM for 4.4 mm width crystals (as used in the HR+ block) was estimated to be 2.1 +/- 0.2 mm. Results from the crystal identification matrix show that the apparent centroids of the crystals are not located at the geometric centers, which would give errors in the reconstruction algorithm assumed uniform sampling. Our results suggest that the additional blurring previously reported in PET scanners with block detectors is not only due to the use of block detectors.
引用
收藏
页码:2201 / 2205
页数:5
相关论文
共 12 条
[1]   Characterization of a single LSO crystal layer high resolution research tomograph [J].
Boellaard, R ;
Buijs, F ;
de Jong, HWAM ;
Lenox, M ;
Gremillion, T ;
Lammertsma, AA .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (04) :429-448
[2]   Investigation of LSO crystals for high spatial resolution positron emission tomography [J].
Casey, ME ;
Eriksson, L ;
Schmand, M ;
Andreaco, MS ;
Paulus, M ;
Dahlbom, M ;
Nutt, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1109-1113
[3]   MicroPET: A high resolution PET scanner for imaging small animals [J].
Cherry, SR ;
Shao, Y ;
Silverman, RW ;
Meadors, K ;
Siegel, S ;
Chatziioannou, A ;
Young, JW ;
Jones, WF ;
Moyers, JC ;
Newport, D ;
Boutefnouchet, A ;
Farquhar, TH ;
Andreaco, M ;
Paulus, MJ ;
Binkley, DM ;
Nutt, R ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1161-1166
[4]   A POSITRON TOMOGRAPH WITH 600-BGO CRYSTALS AND 2.6 MM RESOLUTION [J].
DERENZO, SE ;
HUESMAN, RH ;
CAHOON, JL ;
GEYER, AB ;
MOSES, WW ;
UBER, DC ;
VULETICH, T ;
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :659-664
[5]  
HUBBEL JH, TABLES XRAY MASS ATT
[6]   Initial results from the Sherbrooke avalanche photodiode positron tomograph [J].
Lecomte, R ;
Cadorette, J ;
Rodrigue, S ;
Lapointe, D ;
Rouleau, D ;
Bentourkia, M ;
Yao, R ;
Msaki, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1952-1957
[7]  
LECOMTE R, 1998, COMMUNICATION
[8]   Evaluation of the ECAT EXACT HR+ 3-D PET scanner in H215O brain activation studies:: Dose fractionation strategies for rCBF and signal enhancing protocols [J].
Moreno-Cantú, JJ ;
Thompson, CJ ;
Zatorre, RJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (06) :979-985
[9]  
MOSES WW, 1993, J NUCL MED, V34, pP101
[10]   DETERMINATION OF THE CENTROID OF INTERACTION OF CRYSTALS IN BLOCK DETECTORS FOR PET [J].
PICARD, Y ;
THOMPSON, CJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1464-1468