A comparison of single and double pulse laser-induced breakdown spectroscopy of aluminum samples

被引:231
|
作者
Colao, F
Lazic, V
Fantoni, R
Pershin, S
机构
[1] ENEA, CR Frascati, Dip FISLAS, I-00044 Frascati, Rome, Italy
[2] Inst Gen Phys, Wave Res Ctr, Moscow 119991, Russia
关键词
laser-induced breakdown spectroscopy (LIBS); aluminum; double pulse;
D O I
10.1016/S0584-8547(02)00058-7
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Single and double pulse laser-induced breakdown spectroscopy (LIBS) was carried out on aluminum samples in air. In the case of double pulse excitation, experiments were conducted by using the same laser source operated at the same wavelength (1064 nm in most cases here presented). A lowering of the second pulse plasma threshold was observed, together with an overall enhancement in line emission for the investigated time delay between the two pulses (40-60 mus). The laser-induced plasma originated by a single and double pulse was investigated near ignition threshold with the aim to study possible dynamical mechanisms in different regimes. Currently available spectroscopic diagnostics of plasma, such as the line broadening and shift due Stark effects, have been used in the characterization in order to retrieve electron densities, while standard temperature measurements were based on Boltzmann plot. Plasma relevant parameters, such as temperature and electron density, have been measured in the plasma decay on a long time scale, and compared with crater shape (diameter and inferred volume). The comparison of double with single pulse laser excitation was carried out while keeping constant the energy per pulse; the influence of laser energy was investigated as well. Results here obtained suggest that use of the double pulse technique could significantly improve the analytical capabilities of LIBS technique in routine laboratory experiments. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1167 / 1179
页数:13
相关论文
共 50 条
  • [1] Double pulse laser-induced breakdown spectroscopy with femtosecond laser pulses
    Pinon, V.
    Fotakis, C.
    Nicolas, G.
    Anglos, D.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (10) : 1006 - 1010
  • [2] A compact and portable laser-induced breakdown spectroscopy instrument for single and double pulse applications
    Goujon, J.
    Giakoumaki, A.
    Pinon, V.
    Musset, O.
    Anglos, D.
    Georgiou, E.
    Boquillon, J. P.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (10) : 1091 - 1096
  • [3] Study of the double-pulse setup with an orthogonal beam geometry for laser-induced breakdown spectroscopy
    Gautier, C
    Fichet, P
    Menut, D
    Lacour, JL
    L'Hermite, D
    Dubessy, J
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (07) : 975 - 986
  • [4] Double-pulse laser ablation coupled to laser-induced breakdown spectroscopy
    Glaus, Reto
    Hahn, David W.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 98 : 48 - 53
  • [5] Comparison of detection limits, for two metallic matrices, of laser-induced breakdown spectroscopy in the single and double-pulse configurations
    Ismail, MA
    Cristoforetti, G
    Legnaioli, S
    Pardini, L
    Palleschi, V
    Salvetti, A
    Tognoni, E
    Harith, MA
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (02) : 316 - 325
  • [6] Comparison of single and double pulse laser-induced breakdown spectroscopy for the detection of biomolecules tagged with photon-upconversion nanoparticles
    Farka, Zdenek
    Vytiskova, Karolina
    Makhneva, Ekaterina
    Zikmundova, Eva
    Holub, Daniel
    Buday, Jakub
    Prochazka, David
    Novotny, Karel
    Skladal, Petr
    Porizka, Pavel
    Kaiser, Jozef
    ANALYTICA CHIMICA ACTA, 2024, 1299
  • [7] Comparison of detection limits, for two metallic matrices, of laser-induced breakdown spectroscopy in the single and double-pulse configurations
    Marwa A. Ismail
    Gabriele Cristoforetti
    Stefano Legnaioli
    Lorenzo Pardini
    Vincenzo Palleschi
    Azenio Salvetti
    Elisabetta Tognoni
    Mohamed A. Harith
    Analytical and Bioanalytical Chemistry, 2006, 385 : 316 - 325
  • [8] Optimal emission enhancement in orthogonal double-pulse laser-induced breakdown spectroscopy
    Sangines, R.
    Contreras, V.
    Sobral, H.
    Robledo-Martinez, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 110 : 139 - 145
  • [9] Main parameters influencing the double-pulse laser-induced breakdown spectroscopy in the collinear beam geometry
    Gautier, C
    Fichet, P
    Menut, D
    Lacour, JL
    L'Hermite, D
    Dubessy, J
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (06) : 792 - 804
  • [10] Quantification of the intensity enhancements for the double-pulse laser-induced breakdown spectroscopy in the orthogonal beam geometry
    Gautier, C
    Fichet, P
    Menut, D
    Lacour, JL
    L'Hermite, D
    Dubessy, J
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (02) : 265 - 276