Treating cuff tear arthropathy by reverse total shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical and the radiological outcome?

被引:9
|
作者
Holschen, Malte [1 ,2 ]
Kiriazis, Alexandros [1 ]
Bockmann, Benjamin [3 ]
Schulte, Tobias L. [3 ]
Witt, Kai-Axel [1 ]
Steinbeck, Jorn [1 ]
机构
[1] Orthoped Practice Clin OPPK, Schuerbusch 55, D-48143 Munster, Germany
[2] Raphaelsklin, Munster, Germany
[3] Ruhr Univ Bochum, St Josef Hosp, Dept Orthoped & Trauma Surg, Bochum, Germany
关键词
Reverse total shoulder arthroplasty; Shoulder replacement; Scapular notching; Humeral inclination; Lateral offset; Center of rotation; NECK-SHAFT ANGLE; FOLLOW-UP; RANGE; IMPINGEMENT; ABDUCTION; ROTATION; DESIGN; IMPACT; MOTION;
D O I
10.1007/s00590-021-02976-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeReverse total shoulder arthroplasty is widely used for the treatment of cuff tear arthropathy. Standard implants consist of a humeral component with an inclination angle of 155 degrees and a glenosphere without lateral offset. Recently, lower inclination angles of the humeral component as well as lateralized glenospheres are implanted to provide better rotation of the arm and to decrease the rate of scapular notching. This study investigates the clinical and radiological results of a standard reverse total shoulder in comparison with an implant with an inclination angle of 135 degrees in combination with a 4 mm lateralized glenosphere in context of cuff tear arthropathy. Material and methodsFor this retrospective comparative analysis 42 patients treated by reverse total shoulder arthroplasty for cuff tear arthropathy were included. Twenty-one patients (m=11, f=10; mean age 76 years; mean follow-up 42 months) were treated with a standard 155 degrees humeral component and a standard glenosphere with caudal eccentricity (group A), while twenty-one patients (m=5, f=16; mean age 72 years; mean follow-up 34 months) were treated with a 135 degrees humeral component and 4 mm lateral offset of the glenosphere (group B). At follow-up patients of both groups were assessed with plain X-rays (a.p. and axial view), Constant Score, adjusted Constant Score, the subjective shoulder value and the range of motion. ResultsThe clinical results were similar in both groups concerning the Constant Score (group A=56.3 vs. group B=56.1; p=0.733), the adjusted CS (group A=70.4% vs. group B=68.3%; p=0.589) and the SSV (group A=72.0% vs. group B=75.2%; p=0.947). The range of motion of the operated shoulders did not differ significantly between group A and group B: Abduction=98 degrees versus 97.9 degrees, p=0.655; external rotation with the arm at side=17.9 degrees versus 18.7 degrees, p=0.703; external rotation with the arm positioned in 90 degrees of abduction=22.3 degrees versus 24.7 degrees, p=0.524; forward flexion=116.1 degrees versus 116.7 degrees, p=0.760. The rate of scapular notching was higher (p=0.013) in group A (overall: 66%, grade 1: 29%, grade 2: 29%, grade 3: 10%, grade 4: 0%) in comparison to group B (overall: 33%, grade 1: 33%, grade 2: 0%, grade 3: 0%, grade 4: 0%). Radiolucency around the humeral component was detected in two patients of group B. Stress shielding at the proximal humerus was observed in six patients of Group A (29%; cortical thinning and osteopenia in zone M1 and L1) and two patients of group B (10%; cortical thinning and osteopenia in zone M1 and L1). Calcifications of the triceps origin were observed in both groups (group A=48% vs. group B=38%). ConclusionTheoretically, a lower inclination angle of the humeral component and an increased lateral offset of the glenosphere lead to improved impingement-free range of motion and a decreased rate of scapular notching, when compared to a standard reverse total shoulder implant. This study compared two different designs of numerous options concerning the humeral component and the glenosphere. In comparison to a standard-fashioned implant with a humeral inclination of 155 degrees and a standard glenosphere, implants with a humeral inclination angle of 135 degrees and a 4 mm lateralized glenosphere lead to comparable clinical results and rotatory function, while the rate of scapular notching is decreased by almost 50%. While the different implant designs did not affect the clinical outcome, our results indicate that a combination of a lower inclination angle of the humeral component and lateralized glenosphere should be favored to reduce scapular notching.Level of evidenceLevel III, retrospective comparative study
引用
收藏
页码:307 / 315
页数:9
相关论文
共 36 条
  • [21] The influence of posture and scapulothoracic orientation on the choice of humeral component retrotorsion in reverse total shoulder arthroplasty
    Moroder, Philipp
    Akguen, Doruk
    Plachel, Fabian
    Baur, Alexander D. J.
    Siegert, Paul
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (10) : 1992 - 2001
  • [22] Association of lateral humeral offset with functional outcome and geometric restoration in stemless total shoulder arthroplasty
    Kadum, Bakir
    Wahlstrom, Per
    Khoschnau, Shwan
    Sjoden, Goran
    Sayed-Noor, Arkan
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (10) : E285 - E294
  • [23] A Comparison of Complications and Survivorship after Reverse Total Shoulder Arthroplasty for Proximal Humerus Fracture compared with Cuff Tear Arthropathy
    Wanga, Kevin Y.
    Agarwal, Amil R.
    Best, Matthew J.
    Mawn, John G.
    Kamalapathy, Pramod.
    Srikumaran, Uma.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2023, 11 (03): : 167 - 173
  • [24] Does Humeral Component Version Affect Range of Motion and Clinical Outcomes in Reverse Total Shoulder Arthroplasty? A Systematic Review
    Jassim, Shivan S.
    Ernstbrunner, Lukas
    Ek, Eugene T.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [25] Short-term results of the reverse Total Evolutive Shoulder System (TESS) in cuff tear arthropathy and revision arthroplasty cases
    von Engelhardt, Lars Victor
    Manzke, Michael
    Filler, Timm J.
    Jerosch, Joerg
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (07) : 897 - 904
  • [26] Early clinical and radiological outcomes of reverse shoulder arthroplasty with an eccentric all-polyethylene glenosphere to treat failed hemiarthroplasty and the sequelae of proximal humeral fractures
    Merolla, Giovanni
    Tartarone, Antonio
    Sperling, John W.
    Paladini, Paolo
    Fabbri, Elisabetta
    Porcellini, Giuseppe
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (01) : 141 - 148
  • [27] Rotator cuff tear arthropathy and deltoid avulsion treated with reverse total shoulder arthroplasty and latissimus dorsi transfer: case report and review of the literature
    Goel, Danny P.
    Ross, Douglas C.
    Drosdowech, Darren S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (05) : E1 - E7
  • [28] Conversions from anatomic shoulder replacements to reverse total shoulder arthroplasty: do the indications for initial surgery influence the clinical outcome after revision surgery?
    Malte Holschen
    Bastian Franetzki
    Kai-Axel Witt
    Dennis Liem
    Jörn Steinbeck
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 167 - 172
  • [29] Conversions from anatomic shoulder replacements to reverse total shoulder arthroplasty: do the indications for initial surgery influence the clinical outcome after revision surgery?
    Holschen, Malte
    Franetzki, Bastian
    Witt, Kai-Axel
    Liem, Dennis
    Steinbeck, Joern
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (02) : 167 - 172
  • [30] Clinical and radiological outcome of the Total Evolutive Shoulder System (TESSA®) reverse shoulder arthroplasty: a prospective comparative non-randomised study
    Kadum, Bakir
    Mukka, Sebastian
    Englund, Erling
    Sayed-Noor, Arkan
    Sjoden, Goran
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (05) : 1001 - 1006