Use of heparin-coated stents in neurovascular interventional procedures: Preliminary experience with 10 patients

被引:59
作者
Parkinson, Richard J.
Demers, Christopher P.
Adel, Joseph G.
Levy, Elad I.
Sauvageau, Eric
Hanel, Ricardo A.
Shaibani, Ali
Guterman, Lee R.
Hopkins, L. Nelson
Batjer, H. Hunt
Bendok, Bernard R.
机构
[1] Northwestern Univ, Dept Neurol Surg & Radiol, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Brown Univ, Sch Med, Dept Neurosurg, Providence, RI 02912 USA
[3] St Vincents Clin, Dept Neurosurg, Sydney, NSW, Australia
[4] SUNY Buffalo, Dept Neurosurg, Sch Med & Biomed Sci, Buffalo, NY 14260 USA
[5] SUNY Buffalo, Dept Radiol, Sch Med & Biomed Sci, Buffalo, NY 14260 USA
[6] Buffalo Neurosurg Grp, Dept Neurosurg, W Seneca, NY USA
[7] SUNY Buffalo, Sch Med & Biomed Sci, Toshiba Stroke Res Ctr, Buffalo, NY 14260 USA
关键词
heparin-coated stents; intracranial atherosclerosis; percutaneous transluminal angioplasty and stenting;
D O I
10.1227/01.NEU.0000232836.66310.46
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Currently, there is minimal published data on the use of heparin-coated stents in the neurovasculature; however, these stents have a proven clinical record in the treatment of coronary disease. This article details our experience with the safety and technical aspects of stent deployment in the first 10 patients who had heparin-coated stents placed in the intracranial and cervical vasculature and the preliminary follow-up in most cases. METHODS: We retrospectively reviewed the clinical history, intra- and periprocedural data, and imaging for the patients who received heparin-coated stents in the cervical and intracranial vasculature for cerebrovascular disease between October 2002 and October 2003. RESULTS: Thirteen heparin-coated stents were placed in 10 patients. Seven out of the 10 patients had heparin-coated stents placed in the posterior circulation; the remaining three patients had stents placed in the anterior circulation. Four patients had stents placed intracranially. There was no acute or subacute in-stent thrombosis and no procedure-related complications. Follow-up was performed on most patients, with no clinical symptoms attributable to restenosis in any patient. CONCLUSION: This small series suggests that heparin-coated stents are safe for use in the treatment of cervical and intracranial atherosclerotic disease. Longer-term follow-up is needed to study the heparin coating effect on in-stent restenosis rates and to assess the long-term durability and clinical efficacy of this stent. The use of drug-coated stents in the cerebrovascular circulation is an area that warrants further investigation.
引用
收藏
页码:812 / 821
页数:10
相关论文
共 127 条
[21]   High-performance affinity chromatography for the purification of heparin-binding proteins from detergent-solubilized smooth muscle cell membranes [J].
Clairbois, AS ;
Letourneur, D ;
Muller, D ;
Jozefonvicz, J .
JOURNAL OF CHROMATOGRAPHY B, 1998, 706 (01) :55-62
[22]   Vertebral artery origin angioplasty and primary stenting: safety and restenosis rates in a prospective series [J].
Cloud, GC ;
Crawley, F ;
Clifton, A ;
McCabe, DJH ;
Brown, MM ;
Markus, HS .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2003, 74 (05) :586-590
[23]  
CRAIG PA, 1989, J BIOL CHEM, V264, P5452
[24]   Carotid artery stenting in a vascular surgery practice [J].
Criado, FJ ;
Lingelbach, JM ;
Ledesma, DF ;
Lucas, PR .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (03) :430-434
[25]   Initial results of the quanam drug eluting stent (QuaDS-QP-2) registry (BARDDS) in human subjects [J].
de la Fuente, LM ;
Miano, J ;
Mrad, J ;
Penaloza, E ;
Yeung, AC ;
Eury, R ;
Froix, M ;
Fitzgerald, PJ ;
Stertzer, SH .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (04) :480-488
[26]  
DE SI, 1997, CIRCULATION, V95, P1549
[27]   Sirolimus-eluting stent for treatment of complex in-stent restenosis - The first clinical experience [J].
Degertekin, M ;
Regar, E ;
Tanabe, K ;
Smits, PC ;
van der Giessen, WJ ;
Carlier, SG ;
de Feyter, P ;
Vos, J ;
Foley, DP ;
Ligthart, JMR ;
Popma, JJ ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (02) :184-189
[28]   INVESTIGATION OF 3-SURFACE PROPERTIES OF SEVERAL METALS AND THEIR RELATION TO BLOOD COMPATIBILITY [J].
DEPALMA, VA ;
BAIER, RE ;
GOTT, VL ;
FORD, JW ;
FURUSE, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1972, 6 (04) :37-&
[29]   Aspirin and clopidogrel compared with clopidogrel alone after recent ischaemic stroke or transient ischaemic attack in high-risk patients (MATCH): randomised, double-blind, placebo-controlled trial [J].
Diener, HC ;
Bogousslavsky, J ;
Brass, LM ;
Cimminiello, C ;
Csiba, L ;
Kaste, M ;
Leys, D ;
Matias-Guiv, J ;
Rupprecht, HJ .
LANCET, 2004, 364 (9431) :331-337
[30]   Pathology of acute and chronic coronary stenting in humans [J].
Farb, A ;
Sangiorgi, G ;
Carter, AJ ;
Walley, VM ;
Edwards, WD ;
Schwartz, RS ;
Virmani, R .
CIRCULATION, 1999, 99 (01) :44-52