Thermal performance and thermal resistance of fibre cement roof tiles: Experimental study

被引:11
|
作者
Michels, Caren [1 ]
Guths, Saulo [2 ]
Marinoski, Deivis L. [2 ]
Lamberts, Roberto [2 ]
机构
[1] Univ Fed Amazonas, Architecture & Urbanism Dept, Ave Gen Rodrigo Octavio Jordao Ramos 1200, BR-1200 Manaus, Amazonas, Brazil
[2] Univ Fed Santa Catarina, Civil & Mech Engn Dept, Brazilian Ctr Energy Efficiency Bldg, POB 476, BR-88040970 Florianopolis, SC, Brazil
关键词
Experimental test rig; Heat flow; Roof thermal resistance; Fibre cement tiles; INNOVATIVE COOL ROOF; RADIANT BARRIER; RESIDENTIAL BUILDINGS; ENCLOSED AIRSPACES; SOLAR REFLECTANCE; HEAT-FLOW; INSULATION; ALBEDO; LOADS; MODEL;
D O I
10.1016/j.enbuild.2020.110569
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A better understanding of the thermal performance of construction systems may help engineers and architects to select the most suitable materials for the solutions that meet their objectives. In warm climate countries like Brazil, the thermal performance of roofs is of particular importance. Thus, this study presents an evaluation of the thermal performance of roofs built in reduced scale on an experimental test rig, in Florianopolis, capital of the state of Santa Catarina, southern Brazil. Four roofs were evaluated, all with fibre cement tiles and a polyvinyl chloride (PCV) ceiling: the first was used as a reference, the second had the tiles painted white, the third had a radiant barrier installed and the fourth had conventional thermal insulation based on expanded polystyrene (EPS). All roofs were instrumented with temperature and heat flow sensors and data was collected over a period of eight months. The results show that all of the test roofs had a lower thermal gain than the reference roof, with reductions of 55% for the roof with white tiles, 67% with a radiant barrier and 70% with conventional thermal insulation. The thermal resistance for downward heat flow of the roof with conventional thermal insulation was 1.29 m(2)K/W and that of the roof with the radiant barrier was 1.20 m(2)K/W, with a difference between the two of only 7%. When comparing the thermal resistance obtained experimentally with values obtained with the international standard ISO 6946 and with the Brazilian standard NBR 15220-2 it was found that the radiant barrier roof presented the greatest differences, of 41% and 30%, respectively. This demonstrates that it is important to review the calculation procedure, especially when a radiant barrier is used for thermal insulation. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Simulation and experimental study of thermal performance of a building roof with a phase change material (PCM)
    A MANNIVANNAN
    M T JAFFARSATHIQ ALI
    Sadhana, 2015, 40 : 2381 - 2388
  • [22] NUMERICAL STUDY ON THE THERMAL PERFORMANCE OF DOUBLE ROOF DESIGN
    Zhang, Weihan Warren
    8TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, 2023, : 1769 - 1779
  • [23] Experimental study on the thermal and mechanical performance of graphite-cement based composites
    Guo, Hao-ran
    Qiao, Lan
    Xiao, Yun-yang
    DEEP ROCK MECHANICS: FROM RESEARCH TO ENGINEERING, 2019, : 281 - 288
  • [24] Study on thermal performance of vessel type green roof
    Key Laboratory of New Technology for Construction of Cities in Mountain Area Ministry of Education, Chongqing University, Chongqing 400030, China
    不详
    Chongqing Daxue Xuebao, 2009, 9 (992-996):
  • [25] Fire resistance and thermal performance of hybrid fibre-reinforced magnesium oxychloride cement-based composites
    Ahmad, Farhan
    Rawat, S.
    Yang, Richard
    Zhang, Lihai
    Zhang, Y. X.
    CONSTRUCTION AND BUILDING MATERIALS, 2025, 472
  • [26] Physical, mechanical, and thermal properties of concrete roof tiles produced with vermiculite
    Viana, Queilla Santos
    Carvalho Eugenio, Tony Matheus
    Freire Sabino, Ticyane Pereira
    Soares Scolforo, Jose Roberto
    Mendes, Rafael Farinassi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (32) : 48964 - 48974
  • [27] Physical, mechanical, and thermal properties of concrete roof tiles produced with vermiculite
    Queilla Santos Viana
    Tony Matheus Carvalho Eugênio
    Ticyane Pereira Freire Sabino
    José Roberto Soares Scolforo
    Rafael Farinassi Mendes
    Environmental Science and Pollution Research, 2022, 29 : 48964 - 48974
  • [28] Effect of reflective coating on thermal and electrical performances of solar roof tiles
    Alim, Mohammad A.
    Tao, Zhong
    Saeed, Nariman
    Hao, Xiaojing
    Abden, Md Jaynul
    Rahman, Ataur
    ENERGY CONVERSION AND MANAGEMENT, 2022, 270
  • [29] Thermal performance comparison of recycled and clay roof tiles due heat radiation by digital holographic interferometry
    Sanchez-Alvarez, A.
    De la Torre Ibarra, M. H.
    Mendoza Santoyo, F.
    REVISTA MEXICANA DE FISICA, 2019, 65 (06) : 678 - 683
  • [30] Effect of fly ash cement and polypropylene fibre on the performance of recycled aggregate concrete column under thermal loading: Experimental and numerical study
    Ilango, Saranya
    Singh, Vivek
    Gogoi, Chayanika
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2021, 22 (01) : 42 - 58