Thermal performance and thermal resistance of fibre cement roof tiles: Experimental study

被引:11
作者
Michels, Caren [1 ]
Guths, Saulo [2 ]
Marinoski, Deivis L. [2 ]
Lamberts, Roberto [2 ]
机构
[1] Univ Fed Amazonas, Architecture & Urbanism Dept, Ave Gen Rodrigo Octavio Jordao Ramos 1200, BR-1200 Manaus, Amazonas, Brazil
[2] Univ Fed Santa Catarina, Civil & Mech Engn Dept, Brazilian Ctr Energy Efficiency Bldg, POB 476, BR-88040970 Florianopolis, SC, Brazil
关键词
Experimental test rig; Heat flow; Roof thermal resistance; Fibre cement tiles; INNOVATIVE COOL ROOF; RADIANT BARRIER; RESIDENTIAL BUILDINGS; ENCLOSED AIRSPACES; SOLAR REFLECTANCE; HEAT-FLOW; INSULATION; ALBEDO; LOADS; MODEL;
D O I
10.1016/j.enbuild.2020.110569
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A better understanding of the thermal performance of construction systems may help engineers and architects to select the most suitable materials for the solutions that meet their objectives. In warm climate countries like Brazil, the thermal performance of roofs is of particular importance. Thus, this study presents an evaluation of the thermal performance of roofs built in reduced scale on an experimental test rig, in Florianopolis, capital of the state of Santa Catarina, southern Brazil. Four roofs were evaluated, all with fibre cement tiles and a polyvinyl chloride (PCV) ceiling: the first was used as a reference, the second had the tiles painted white, the third had a radiant barrier installed and the fourth had conventional thermal insulation based on expanded polystyrene (EPS). All roofs were instrumented with temperature and heat flow sensors and data was collected over a period of eight months. The results show that all of the test roofs had a lower thermal gain than the reference roof, with reductions of 55% for the roof with white tiles, 67% with a radiant barrier and 70% with conventional thermal insulation. The thermal resistance for downward heat flow of the roof with conventional thermal insulation was 1.29 m(2)K/W and that of the roof with the radiant barrier was 1.20 m(2)K/W, with a difference between the two of only 7%. When comparing the thermal resistance obtained experimentally with values obtained with the international standard ISO 6946 and with the Brazilian standard NBR 15220-2 it was found that the radiant barrier roof presented the greatest differences, of 41% and 30%, respectively. This demonstrates that it is important to review the calculation procedure, especially when a radiant barrier is used for thermal insulation. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 38 条
  • [11] Instituto nacional de metrologia (INMETRO), 2010, REG TECN QUAL NIV EF, P96
  • [12] ISO, 2014, 9869 ISO
  • [13] Reflective thermal insulation systems in building: A review on radiant barrier and reflective insulation
    Lee, Sau Wai
    Lim, Chin Haw
    Bin Salleh, Elias Ilias
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 65 : 643 - 661
  • [14] On the performance of radiant barriers in combination with different attic insulation levels
    Medina, MA
    [J]. ENERGY AND BUILDINGS, 2000, 33 (01) : 31 - 40
  • [15] Evaluating the sensitivity of attic radiant barrier performance to climate parameters
    Medina, Mario A.
    Young, C. Bryan
    [J]. JOURNAL OF ENERGY ENGINEERING, 2008, 134 (01) : 2 - 5
  • [16] Michels C., 2018, ENCONTRO NAC TECNOL
  • [17] Evaluation of heat flux reduction provided by the use of radiant barriers in clay tile roofs
    Michels, Caren
    Larnberts, Roberto
    Gueths, Saulo
    [J]. ENERGY AND BUILDINGS, 2008, 40 (04) : 445 - 451
  • [18] Development of an experimental test rig for the evaluation of the thermal performance of building roofs
    Michels, Caren
    Guths, Saulo
    Marinoski, Deivis L.
    Lamberts, Roberto
    [J]. ENERGY AND BUILDINGS, 2018, 180 : 32 - 41
  • [19] Evaluation of the thermal resistance of a roof-mounted multi-reflective radiant barrier for tropical and humid conditions: Experimental study from field measurements
    Miranville, Frederic
    Fakra, Ali Hamada
    Guichard, Stephane
    Boyer, Harry
    Praene, Jean-Philippe
    Bigot, Dimitri
    [J]. ENERGY AND BUILDINGS, 2012, 48 : 79 - 90
  • [20] Studies on solar passive cooling techniques for arid areas
    Nahar, NM
    Sharma, P
    Purohit, MM
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (01) : 89 - 95