Thermal performance and thermal resistance of fibre cement roof tiles: Experimental study

被引:11
|
作者
Michels, Caren [1 ]
Guths, Saulo [2 ]
Marinoski, Deivis L. [2 ]
Lamberts, Roberto [2 ]
机构
[1] Univ Fed Amazonas, Architecture & Urbanism Dept, Ave Gen Rodrigo Octavio Jordao Ramos 1200, BR-1200 Manaus, Amazonas, Brazil
[2] Univ Fed Santa Catarina, Civil & Mech Engn Dept, Brazilian Ctr Energy Efficiency Bldg, POB 476, BR-88040970 Florianopolis, SC, Brazil
关键词
Experimental test rig; Heat flow; Roof thermal resistance; Fibre cement tiles; INNOVATIVE COOL ROOF; RADIANT BARRIER; RESIDENTIAL BUILDINGS; ENCLOSED AIRSPACES; SOLAR REFLECTANCE; HEAT-FLOW; INSULATION; ALBEDO; LOADS; MODEL;
D O I
10.1016/j.enbuild.2020.110569
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A better understanding of the thermal performance of construction systems may help engineers and architects to select the most suitable materials for the solutions that meet their objectives. In warm climate countries like Brazil, the thermal performance of roofs is of particular importance. Thus, this study presents an evaluation of the thermal performance of roofs built in reduced scale on an experimental test rig, in Florianopolis, capital of the state of Santa Catarina, southern Brazil. Four roofs were evaluated, all with fibre cement tiles and a polyvinyl chloride (PCV) ceiling: the first was used as a reference, the second had the tiles painted white, the third had a radiant barrier installed and the fourth had conventional thermal insulation based on expanded polystyrene (EPS). All roofs were instrumented with temperature and heat flow sensors and data was collected over a period of eight months. The results show that all of the test roofs had a lower thermal gain than the reference roof, with reductions of 55% for the roof with white tiles, 67% with a radiant barrier and 70% with conventional thermal insulation. The thermal resistance for downward heat flow of the roof with conventional thermal insulation was 1.29 m(2)K/W and that of the roof with the radiant barrier was 1.20 m(2)K/W, with a difference between the two of only 7%. When comparing the thermal resistance obtained experimentally with values obtained with the international standard ISO 6946 and with the Brazilian standard NBR 15220-2 it was found that the radiant barrier roof presented the greatest differences, of 41% and 30%, respectively. This demonstrates that it is important to review the calculation procedure, especially when a radiant barrier is used for thermal insulation. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Analysis of the impact of thermal resistance of the roof on the performance of photovoltaic roof tiles
    Kurz, Dariusz
    Nawrowski, Ryszard
    INTERNATIONAL CONFERENCE ENERGY, ENVIRONMENT AND MATERIAL SYSTEMS (EEMS 2017), 2017, 19
  • [2] Cement roof tiles manufactured with PET waste: Experimental tests and thermal building simulations
    Callejas, Ivan Julio Apolonio
    da Guarda, Emeli Lalesca Aparecida
    Durante, Luciane Cleonice
    Kruger, Eduardo
    JOURNAL OF CLEANER PRODUCTION, 2025, 495
  • [3] Experimental study on the thermal performance of insulating materials for metal tiles
    Reis, Mari Aurora Favero
    Cechin, Luana
    Fretta, Mauro Acir
    Reis Jr, Paulo
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 57
  • [4] Experimental study of the thermal performance of a new type of PV roof
    Tian, Ruian
    Meng, Erlin
    Shu, Yue
    Li, Jun
    Zhou, Bo
    Zhao, Haiqian
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 157
  • [5] Assessment of thermal cracking in concrete roof tiles
    Rajeev, P.
    Sanjayan, Jay G.
    Seenuth, S. S.
    MATERIALS & DESIGN, 2016, 107 : 470 - 477
  • [6] THE GREEN ROOF THERMAL PERFORMANCE EVALUATION IN COMPARISON TO ASBESTOS CEMENT TILES APPLIED TO LIGHT STEEL FRAME BRAZILIAN BUILDINGS
    Guiao Marcato Costa, Angelica Felicidade
    Paschoalin Filho, Joao Alexandre
    Philipi Cortese, Tatiana Tucunduva
    Coelho Leite, Brenda Chaves
    ARCHNET-IJAR INTERNATIONAL JOURNAL OF ARCHITECTURAL RESEARCH, 2018, 12 (03) : 288 - 307
  • [7] Experimental Study on the Permeability and Thermal Resistance of the Cement Clinker Accumulation
    Wen, Yan
    Wang, Jia-shun
    Yue, Hai-long
    Jing, Tong
    Liu, Bin
    HEAT TRANSFER-ASIAN RESEARCH, 2016, 45 (02): : 134 - 143
  • [8] Experimental study on the thermal performance of composite phase change ventilated roof
    Hou, Mingdong
    Kong, Xiangfei
    Li, Han
    Yang, Hua
    Chen, Wanhe
    JOURNAL OF ENERGY STORAGE, 2021, 33
  • [9] Experimental study on thermal effect of green roof and roof spraying
    Ichinose, Shigehiro
    Ishikawa, Yukio
    Nomoto, Tomoko
    Umebayashi, Kei
    Kiriyama, Taizou
    Hazumoto, Yoshihiro
    AIJ Journal of Technology and Design, 2009, 15 (30) : 475 - 479
  • [10] Thermal Effect of Firebrand Accumulation in Ceramic Roof Tiles
    Zitouni, Mohamed
    Arruda, Mario Rui Tiago
    Cantor, Pedro
    Branco, Fernando
    FIRE-SWITZERLAND, 2025, 8 (02):