A Control Methodology and Characterization of Dynamics for a Photovoltaic (PV) System Interfaced With a Distribution Network

被引:221
作者
Yazdani, Amirnaser [1 ]
Dash, Prajna Paramita [1 ]
机构
[1] Univ Western Ontario, London, ON NGA 5B9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Control; eigenvalue analysis; feedforward; modal analysis; participation factor; photovoltaic (PV); power electronics; voltage-source converter (VSC); GRID-CONNECTED INVERTERS; PERFORMANCE;
D O I
10.1109/TPWRD.2009.2016632
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a control strategy for a single-stage, three-phase, photovoltaic (PV) system that is connected to a distribution network. The control is based on an inner current-control loop and an outer dc-link voltage regulator. The current-control mechanism decouples the PV system dynamics from those of the network and the loads. The dc-link voltage-control scheme enables control and maximization of the real power output. Proper feedforward actions are proposed for the current-control loop to make its dynamics independent of those of the rest of the system. Further, a feedforward compensation mechanism is proposed for the dc-link voltage-control loop, to make the PV system dynamics immune to the PV array nonlinear characteristic. This, in turn, permits the design and optimization of the PV system controllers for a wide range of operating conditions. A modal/sensitivity analysis is also conducted on a linearized model of the overall system, to characterize dynamic properties of the system, to evaluate robustness of the controllers, and to identify the nature of interactions between the PV system and the network/loads. The results of the modal analysis confirm that under the proposed control strategy, dynamics of the PV system are decoupled from those of the distribution network and, therefore, the PV system does not destabilize the distribution network. It is also shown that the PV system dynamics are not influenced by those of the network (i.e., the PV system maintains its stability and dynamic properties despite major variations in the line length, line X/R ratio, load type, and load distance from the PV system).
引用
收藏
页码:1538 / 1551
页数:14
相关论文
共 38 条
[1]   AN APPROACH TO ASSESS THE PERFORMANCE OF UTILITY-INTERACTIVE PHOTOVOLTAIC SYSTEMS [J].
ABOUZAHR, I ;
RAMAKUMAR, R .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1993, 8 (02) :145-153
[2]  
[Anonymous], P IEEE INT C POW EL
[3]  
Benhabib M. C., 2007, INT C EL POW QUAL UT
[4]   THE NEW-ENGLAND ELECTRIC PHOTOVOLTAIC SYSTEMS RESEARCH AND DEMONSTRATION PROJECT [J].
BZURA, JJ .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (02) :284-289
[5]   PERFORMANCE OF GRID-CONNECTED PHOTOVOLTAIC SYSTEMS ON RESIDENCES AND COMMERCIAL BUILDINGS IN NEW-ENGLAND [J].
BZURA, JJ .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1992, 7 (01) :79-82
[6]   AN ANALYSIS OF THE HARMONICS AND POWER-FACTOR EFFECTS AT A UTILITY INTERTIED PHOTO-VOLTAIC SYSTEM [J].
CAMPEN, GL .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (12) :4632-4639
[7]   A phase tracking system for three phase utility interface inverters [J].
Chung, SK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :431-438
[8]   Harmonic interaction between a large number of distributed power inverters and the distribution network [J].
Enslin, JHR ;
Heskes, PJM .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (06) :1586-1593
[9]   Comparison of photovoltaic array maximum power point tracking techniques [J].
Esram, Trishan ;
Chapman, Patrick L. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (02) :439-449
[10]  
FIGUERES E, 2007, P EUR C POW EL APPL