A phantom study to evaluate three different registration platform of 3D/3D, 2D/3D, and 3D surface match with 6D alignment for precise image-guided radiotherapy

被引:10
作者
Kuo, Hsiang-Chi [1 ,2 ]
Lovelock, Michael M. [1 ]
Li, Guang [1 ]
Ballangrud, Ase [1 ]
Wolthuis, Brian [2 ]
Della Biancia, Cesar [1 ]
Hunt, Margie A. [1 ]
Berry, Sean L. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Med Phys Dept, 1275 York Ave, New York, NY 10021 USA
[2] Norwalk Hosp, Radiat Oncol Dept, Norwalk, CT 06856 USA
关键词
IGRT; image registration; target registration error; PATIENT SETUP; SYSTEM; ACCURACY; HEAD; ALGORITHMS;
D O I
10.1002/acm2.13086
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate two three-dimensional (3D)/3D registration platforms, one two-dimensional (2D)/3D registration method, and one 3D surface registration method (3DS). These three technologies are available to perform six-dimensional (6D) registrations for image-guided radiotherapy treatment. Methods Fiducial markers were asymmetrically placed on the surfaces of an anthropomorphic head phantom (n = 13) and a body phantom (n = 8), respectively. The point match (PM) solution to the six-dimensional (6D) transformation between the two image sets [planning computed tomography (CT) and cone beam CT (CBCT)] was determined through least-square fitting of the fiducial positions using singular value decomposition (SVD). The transformation result from SVD was verified and was used as the gold standard to evaluate the 6D accuracy of 3D/3D registration in Varian's platform (3D3DV), 3D/3D and 2D/3D registration in the BrainLab ExacTrac system (3D3DE and 2D3D), as well as 3DS in the AlignRT system. Image registration accuracy from each method was quantitatively evaluated by root mean square of target registration error (rmsTRE) on fiducial markers and by isocenter registration error (IRE). The Wilcoxon signed-rank test was utilized to compare the difference of each registration method with PM. A P rmsTRE was in the range of 0.4 mm/0.7 mm (cranial/body), 0.5 mm/1 mm, 1.0 mm/1.5 mm, and 1.0 mm/1.2 mm for PM, 3D3D, 2D3D, and 3DS, respectively. Comparing to PM, the mean errors of IRE were 0.3 mm/1 mm for 3D3D, 0.5 mm/1.4 mm for 2D3D, and 1.6 mm/1.35 mm for 3DS for the cranial and body phantoms respectively. Both of 3D3D and 2D3D methods differed significantly in the roll direction as compared to the PM method for the cranial phantom. The 3DS method was significantly different from the PM method in all three translation dimensions for both the cranial (P = 0.003-P = 0.03) and body (P P = 0.008) phantoms. Conclusion 3D3D using CBCT had the best image registration accuracy among all the tested methods. 2D3D method was slightly inferior to the 3D3D method but was still acceptable as a treatment position verification device. 3DS is comparable to 2D3D technique and could be a substitute for X-ray or CBCT for pretreatment verification for treatment of anatomical sites that are rigid.
引用
收藏
页码:188 / 196
页数:9
相关论文
共 30 条
[1]   3D registration using a new implementation of the ICP algorithm based on a comprehensive lookup matrix:: Application to medical imaging [J].
Almhdie, Ahmad ;
Leger, Christophe ;
Deriche, Mohamed ;
Ledee, Roger .
PATTERN RECOGNITION LETTERS, 2007, 28 (12) :1523-1533
[2]  
Belcher AH, 2016, MED PHYS, V43, P2785, DOI 10.1118/1.4948506
[3]   A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup [J].
Bert, C ;
Metheany, KG ;
Doppke, K ;
Chen, GTY .
MEDICAL PHYSICS, 2005, 32 (09) :2753-2762
[4]   Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task [J].
Brock, Kristy K. ;
Mutic, Sasa ;
McNutt, Todd R. ;
Li, Hua ;
Kessler, Marc L. .
MEDICAL PHYSICS, 2017, 44 (07) :E43-E76
[5]   Estimating 3-D rigid body transformations: A comparison of four major algorithms [J].
Eggert, DW ;
Lorusso, A ;
Fischer, RB .
MACHINE VISION AND APPLICATIONS, 1997, 9 (5-6) :272-290
[6]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[7]  
Fitzpatrick JM, HDB MED IMAGING, V2
[8]   A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery [J].
Fu, Dongshan ;
Kuduvalli, Gopinath .
MEDICAL PHYSICS, 2008, 35 (05) :2180-2194
[9]   Structured-light 3D surface imaging: a tutorial [J].
Geng, Jason .
ADVANCES IN OPTICS AND PHOTONICS, 2011, 3 (02) :128-160
[10]   Evaluation of the Accuracy of a 3D Surface Imaging System for Patient Setup in Head and Neck Cancer Radiotherapy [J].
Gopan, Olga ;
Wu, Qiuwen .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (02) :547-552