A disposable, simple, fast and low-cost paper-based biosensor and its application to the determination of glucose in commercial orange juices

被引:53
作者
Guadarrama-Fernandez, Leonor [1 ]
Novell, Marta [1 ]
Blondeau, Pascal [1 ]
Andrade, Francisco J. [1 ]
机构
[1] Univ Rovira & Virgili, Dept Quim Analit & Quim Organ, C Marcelli Domingo 1, E-43007 Tarragona, Spain
关键词
Electrochemical sensor; Potentiometric detection; Glucose sensing; Paper-based platforms; OXIDASE; IMMOBILIZATION; SELECTIVITY; ELECTRODE; BLEND;
D O I
10.1016/j.foodchem.2018.05.082
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new biosensor for monitoring glucose levels in beverages is presented. The measurements are performed using potentiometric detection. Working electrodes are made using platinised paper as support and a biocompatible polymeric membrane made of a mixture of polyvinyl alcohol and chitosan containing glucose oxidase as the recognition layer. The system is based on the detection of the hydrogen peroxide generated by an enzymatic reaction performed in a highly sensitive, selective and simple way. The biosensors display suitable analytical performance (sensitivity -119.6 +/- 6.4 mV/dec in the 0.03-1.0 mM range with a limit of detection of 0.02 mM). Determination of glucose in commercial orange juices is presented. These results were validated against conventional standard methods, showing good accuracy and fast analytical response. The methodology presented herein does not require complex samples treatment, offering an alternative to conventional methods, particularly for determinations performed with minimal expertise and without a laboratory infrastructure.
引用
收藏
页码:64 / 69
页数:6
相关论文
共 37 条
[21]   Nanotechnology for the Food and Bioprocessing Industries [J].
Neethirajan, Suresh ;
Jayas, Digvir S. .
FOOD AND BIOPROCESS TECHNOLOGY, 2011, 4 (01) :39-47
[22]   A paper-based potentiometric cell for decentralized monitoring of Li levels in whole blood [J].
Novell, Marta ;
Guinovart, Tomas ;
Blondeau, Pascal ;
Xavier Rius, F. ;
Andrade, Francisco J. .
LAB ON A CHIP, 2014, 14 (07) :1308-1314
[23]   Paper-Based Ion-Selective Potentiometric Sensors [J].
Novell, Marta ;
Parrilla, Marc ;
Crespo, Gaston A. ;
Xavier Rius, F. ;
Andrade, Francisco J. .
ANALYTICAL CHEMISTRY, 2012, 84 (11) :4695-4702
[24]  
Parrilla M., 2016, ELECTROANAL, P1
[25]   Paper-based enzymatic electrode with enhanced potentiometric response for monitoring glucose in biological fluids [J].
Parrilla, Marc ;
Canovas, Rocio ;
Andrade, Francisco J. .
BIOSENSORS & BIOELECTRONICS, 2017, 90 :110-116
[26]   Amperometric Biosensor for Direct Blood Lactate Detection [J].
Ricardo Romero, Marcelo ;
Ahumada, Facundo ;
Garay, Fernando ;
Baruzzi, Ana M. .
ANALYTICAL CHEMISTRY, 2010, 82 (13) :5568-5572
[27]   Enzyme immobilization: The quest for optimum performance [J].
Sheldon, Roger A. .
ADVANCED SYNTHESIS & CATALYSIS, 2007, 349 (8-9) :1289-1307
[28]  
Spreen T. H., 2001, 2001 CHIN FAO S CITR, P5
[29]   Properties and sorption studies of chitosan-polyvinyl alcohol blend films [J].
Srinivasa, PC ;
Ramesh, MN ;
Kumar, KR ;
Tharanathan, RN .
CARBOHYDRATE POLYMERS, 2003, 53 (04) :431-438
[30]   Glucose oxidase, lactate oxidase, and galactose oxidase enzyme electrode based on polypyrrole with polyanion/PEG/enzyme conjugate dopant [J].
Sung, WJ ;
Bae, YH .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) :164-169