Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

被引:2
|
作者
Li, Cheng [1 ]
Li, Le [2 ]
Li, Junming [3 ]
Zhang, Yajun [2 ]
Li, Zhihui [1 ]
机构
[1] State Nucl Power Technol Res & Dev Ctr, Beijing 102209, Peoples R China
[2] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Key Lab Thermal Sci & Power Engn, Minist Educ, Dept Thermal Engn, Beijing 100084, Peoples R China
关键词
Shell thermal conduction; AP1000; containment; Wetted coverage; Condensation and evaporation; CONDENSATION; EVAPORATION;
D O I
10.1016/j.nucengdes.2016.12.022
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
AP1000 containment uses the water film evaporation, coupled with containment inner condensation, to remove the core decay heat. However, water film cannot fully cover heat transfer surface and dry-wetted strips appear. As a result, heat transfer within the containment shell is a two-dimension thermal conduction. Current work numerically studied the AP1000 heat removal enhancement due to the partially wetted coverage phenomenon. It used the evaporation and condensation boundary conditions and Fluent software to calculate the local heat fluxes and their distributions. Results show that the maximum heat transfer enhancement can reach 63% and this enhancement peak appears when the dry strip fraction approximately equals 90%. The influences of dry coverage and dry-wet strip width were carefully discussed. It indicates that the heat transfer enhancement for small dry-wet strip is linear with dry strip fraction (0 < alpha < 80%). Finally, according to the wetted coverage ranges for AP1000 passive containment cooling system, an empirical correlation for heat transfer enhancement is given and it can be used to improve PCCS analysis. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 3 条
  • [1] Analysis on pressure response of containment subcompartments for AP1000
    Cai, Wei
    Chen, Wen-Hu
    Xu, Liang-Wang
    Zhang, Ying
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2013, 47 (12): : 2267 - 2271
  • [2] Prediction of falling film evaporation on the AP1000 paSsive containment cooling system using ANSYS FLUENT code
    Wang, Xianmao
    Chang, Huajian
    Corradini, Michael
    Cong, Tenglong
    Wang, Jun
    ANNALS OF NUCLEAR ENERGY, 2016, 95 : 168 - 175
  • [3] Analysis on containment thermal hydraulic behaviour under passive containment heat removal system operation condition for HPR1000
    Sun J.
    Wang H.
    Li J.
    International Journal of Advanced Nuclear Reactor Design and Technology, 2022, 4 (01): : 36 - 42