Are Centrifugal Ventricular Assist Devices the Answer to Reducing Post-Implantation Gastrointestinal Bleeding?

被引:8
作者
Crow, Sheri S. [1 ]
Joyce, Daniel D. [1 ]
机构
[1] Mayo Rochester, Dept Crit Care Med, Rochester, MN 55905 USA
关键词
bleeding; HeartMate II; HeartWare; left ventricular assist device; von Willebrand syndrome; VON-WILLEBRAND-FACTOR; ACTIVITY ASSAY; RECIPIENTS;
D O I
10.1016/j.jchf.2013.11.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:146 / 147
页数:2
相关论文
共 11 条
[1]   Shear-induced unfolding activates von Willebrand factor A2 domain for proteolysis [J].
Baldauf, C. ;
Schneppenheim, R. ;
Stacklies, W. ;
Obser, T. ;
Pieconka, A. ;
Schneppenheim, S. ;
Budde, U. ;
Zhou, J. ;
Graeter, F. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (12) :2096-2105
[2]  
Chen D, 2008, J THROMB HAEMOST, V6, P323, DOI 10.1111/j.1538-7836.2008.02845.x
[3]   Validation of an automated latex particle-enhanced immunoturbidimetric von Willebrand factor activity assay [J].
Chen, D. ;
Tange, J. I. ;
Meyers, B. J. ;
Pruthi, R. K. ;
Nichols, W. L. ;
Heit, J. A. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (10) :1993-2002
[4]   Acquired von Willebrand Syndrome in Continuous-Flow Ventricular Assist Device Recipients [J].
Crow, Sheri ;
Chen, Dong ;
Milano, Carmelo ;
Thomas, William ;
Joyce, Lyle ;
Piacentino, Valentino, III ;
Sharma, Riti ;
Wu, Jogin ;
Arepally, Gowthami ;
Bowles, Dawn ;
Rogers, Joseph ;
Villamizar-Ortiz, Nestor .
ANNALS OF THORACIC SURGERY, 2010, 90 (04) :1263-1269
[5]   Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices [J].
Crow, Sheri ;
John, Ranjit ;
Boyle, Andrew ;
Shumway, Sara ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Toninato, Carol ;
Missov, Emil ;
Pritzker, Marc ;
Martin, Cindy ;
Garry, Daniel ;
Thomas, William ;
Joyce, Lyle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :208-215
[6]   von Willebrand factor: Measuring its antigen or function? Correlation between the level of antigen, activity, and multimer size using various detection systems [J].
Fischer, BE ;
Thomas, KB ;
Dorner, F .
THROMBOSIS RESEARCH, 1998, 91 (01) :39-43
[7]   Pilot investigation of a novel testing strategy for bleeding in ventricular assist device recipients [J].
Joyce, David ;
Crow, Sheri ;
Li, Zhuo ;
Joyce, Lyle ;
Milano, Carmelo ;
Rogers, Joseph ;
Villamizar-Ortiz, Nestor ;
Chen, Dong .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (07) :750-756
[8]   Acquired von Willebrand Syndrome in Patients With a Centrifugal or Axial Continuous Flow Left Ventricular Assist Device [J].
Meyer, Anna L. ;
Malehsa, Doris ;
Budde, Ulrich ;
Bara, Christoph ;
Haverich, Axel ;
Strueber, Martin .
JACC-HEART FAILURE, 2014, 2 (02) :141-145
[9]   Acquired von Willebrand Syndrome in Patients With an Axial Flow Left Ventricular Assist Device [J].
Meyer, Anna L. ;
Malehsa, Doris ;
Bara, Christoph ;
Budde, Ulrich ;
Slaughter, Mark S. ;
Haverich, Axel ;
Strueber, Martin .
CIRCULATION-HEART FAILURE, 2010, 3 (06) :675-681
[10]   Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist Device [J].
Slaughter, Mark S. ;
Rogers, Joseph G. ;
Milano, Carmelo A. ;
Russell, Stuart D. ;
Conte, John V. ;
Feldman, David ;
Sun, Benjamin ;
Tatooles, Antone J. ;
Delgado, Reynolds M., III ;
Long, James W. ;
Wozniak, Thomas C. ;
Ghumman, Waqas ;
Farrar, David J. ;
Frazier, O. Howard .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (23) :2241-2251