The availability of gated SPECT has increased the interest in the determination of volume and ejection fraction of the left ventricle (LV) for clinical diagnosis, However, the same indices for the right ventricle (RV) have been neglected, The objective of this investigation was to use a mathematical model of the anatomical distribution of activity in gated blood-pool imaging to evaluate the accuracy of two ventricular volume and ejection fraction determination methods, In this investigation, measurements from the RV were emphasized, Methods: The mathematical cardiac torso phantom, developed to study LV myocardium perfusion, was modified to simulate the radioactivity distribution of a Tc-99m-gated blood-pool study, Twenty mathematical cardiac torso phantom models of the normal heart with different LV volumes (122.3 +/- 11.0 ml), RV volumes (174.6 +/- 22.3 ml) and stroke volumes (75.7 +/- 3.3 ml) were randomly generated to simulate variations among patients. An analytical three-dimensional projector with attenuation and system response was used to generate SPECT projection sets, after which noise was added. The projections were simulated for 128 equidistant views in a 360 degrees rotation mode. Results: The radius of rotation was varied between 24 and 28 cm to mimic such variation in patient acquisitions, The 180 degrees and 360 degrees projection sets were reconstructed using the filtered backprojection reconstruction algorithm with Butterworth filtering. Comparison was made with and without application of the iterative Chang attenuation correction algorithm. Volumes were calculated using a modified threshold and edge detection method (hybrid threshold), as well as a count-based method, A simple background correction procedure was used with both methods, Conclusion: Results indicate that cardiac functional parameters can be measured with reasonable accuracy using both methods, However, the count-based method had a larger bias than the hybrid threshold method when RV parameters were determined for 180 degrees reconstruction without attenuation correction, This bias improved after attenuation correction. The count-based method also tended to overestimate the end systolic volume slightly, An improved background correction could possibly alleviate this bias.
引用
收藏
页码:1528 / 1535
页数:8
相关论文
共 50 条
  • [31] Pressure-based estimation of right ventricular ejection fraction
    Heerdt, Paul M.
    Singh, Inderjit
    Elassal, Ahmed
    Kheyfets, Vitaly
    Richter, Manuel J.
    Tello, Khodr
    ESC HEART FAILURE, 2022, 9 (02): : 1436 - 1443
  • [32] INVITRO VALIDATION OF A RIGHT VENTRICULAR THERMODILUTION EJECTION FRACTION SYSTEM
    MUKHERJEE, R
    SPINALE, FG
    VONRECUM, AF
    CRAWFORD, FA
    ANNALS OF BIOMEDICAL ENGINEERING, 1991, 19 (02) : 165 - 177
  • [33] A new method for quantification of left ventricular systolic function using a corrected ejection fraction
    MacIver, David H.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (03): : 228 - 234
  • [34] Assessment of left ventricular ejection fraction after myocardial infarction using contrast echocardiography
    Galema, Tjebbe W.
    Geleijnse, Marcel L.
    Yap, Sing-Chien
    van Domburg, Ron T.
    Biagini, Elena
    Vletter, Wim B.
    Ten Cate, Folkert J.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2008, 9 (02): : 250 - 254
  • [35] Reliable Estimation of Left Ventricular Ejection Fraction Using High Resolution Surface Electrocardiography
    Exner, Derek V.
    Burton, Tim
    Ramchandani, Shyam
    Kavanagh, Katherine M.
    Ellis, Linda
    Yazdi, Mohsen
    Gupta, Sunny
    CIRCULATION, 2013, 128 (22)
  • [36] Noninvasive iPhone Measurement of Left Ventricular Ejection Fraction Using Intrinsic Frequency Methodology
    Pahlevan, Niema M.
    Rinderknecht, Derek G.
    Tavallali, Peyman
    Razavi, Marianne
    Tran, Thao T.
    Fong, Michael W.
    Kloner, Robert A.
    Csete, Marie
    Gharib, Morteza
    CRITICAL CARE MEDICINE, 2017, 45 (07) : 1115 - 1120
  • [37] Echocardiographic methods for quantification of left ventricular ejection fraction: are they interchangeable?
    Self, Stuart
    Allen, Jane
    Oxborough, David
    ULTRASOUND, 2010, 18 (02) : 73 - 81
  • [38] Comparison of Visual and Quantitative Assessment of Left Ventricular Ejection Fraction
    Esenboga, Kerim
    Kilickap, Mustafa
    Kaya, Canstn Tulunay
    Peker, Elif
    Koca, Cigdem
    Kozluca, Volkan
    Erol, Cetin
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (08) : E1 - E1
  • [39] Evaluation of the Left Ventricular Ejection Fraction with Gated IQ-SPECT Myocardial Perfusion Imaging
    Joergensen, Troels
    Hansson, Susanne Haase
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2015, 43 (03) : 193 - 200
  • [40] Comparison between tagged MRI and standard cine MRI for evaluation of left ventricular ejection fraction
    Dornier, C
    Somsen, GA
    Ivancevic, MK
    Osman, NF
    Didier, D
    Righetti, A
    Vallée, JP
    EUROPEAN RADIOLOGY, 2004, 14 (08) : 1348 - 1352