The availability of gated SPECT has increased the interest in the determination of volume and ejection fraction of the left ventricle (LV) for clinical diagnosis, However, the same indices for the right ventricle (RV) have been neglected, The objective of this investigation was to use a mathematical model of the anatomical distribution of activity in gated blood-pool imaging to evaluate the accuracy of two ventricular volume and ejection fraction determination methods, In this investigation, measurements from the RV were emphasized, Methods: The mathematical cardiac torso phantom, developed to study LV myocardium perfusion, was modified to simulate the radioactivity distribution of a Tc-99m-gated blood-pool study, Twenty mathematical cardiac torso phantom models of the normal heart with different LV volumes (122.3 +/- 11.0 ml), RV volumes (174.6 +/- 22.3 ml) and stroke volumes (75.7 +/- 3.3 ml) were randomly generated to simulate variations among patients. An analytical three-dimensional projector with attenuation and system response was used to generate SPECT projection sets, after which noise was added. The projections were simulated for 128 equidistant views in a 360 degrees rotation mode. Results: The radius of rotation was varied between 24 and 28 cm to mimic such variation in patient acquisitions, The 180 degrees and 360 degrees projection sets were reconstructed using the filtered backprojection reconstruction algorithm with Butterworth filtering. Comparison was made with and without application of the iterative Chang attenuation correction algorithm. Volumes were calculated using a modified threshold and edge detection method (hybrid threshold), as well as a count-based method, A simple background correction procedure was used with both methods, Conclusion: Results indicate that cardiac functional parameters can be measured with reasonable accuracy using both methods, However, the count-based method had a larger bias than the hybrid threshold method when RV parameters were determined for 180 degrees reconstruction without attenuation correction, This bias improved after attenuation correction. The count-based method also tended to overestimate the end systolic volume slightly, An improved background correction could possibly alleviate this bias.
引用
收藏
页码:1528 / 1535
页数:8
相关论文
共 50 条
  • [1] Ejection fraction as related to basic components in the left and right ventricular volume domains
    Kerkhof, Peter L. M.
    van de Ven, Peter M.
    Yoo, Byungwon
    Peace, Richard A.
    Heyndrickx, Guy R.
    Handly, Neal
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 255 : 105 - 110
  • [2] Right ventricular ejection fraction with cardiac magnetic resonance using a wall motion score*
    Lebeau, Real
    Page, Maude
    Serri, Karim
    Pichette, Maxime
    Di Lorenzo, Maria
    Sauve, Claude
    Vinet, Alain
    Poulina, Frederic
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2022, 115 (03) : 126 - 133
  • [3] The Volume Regulation Graph versus the Ejection Fraction as Metrics of Left Ventricular Performance in Heart Failure with and without a Preserved Ejection Fraction: A Mathematical Model Study
    Faes, Theo J. C.
    Kerkhof, Peter L. M.
    CLINICAL MEDICINE INSIGHTS-CARDIOLOGY, 2015, 9 : 73 - 91
  • [4] Left ventricular volume regulation in heart failure with preserved ejection fraction
    Kerkhof, Peter L. M.
    Kresh, J. Yasha
    Li, John K. -J.
    Heyndrickx, Guy R.
    PHYSIOLOGICAL REPORTS, 2013, 1 (02):
  • [5] Cardiac volumes and left ventricular ejection fraction on myocardial perfusion scintigraphy
    Lee, Joseph C.
    Chong, Jia Wen
    WORLD JOURNAL OF NUCLEAR MEDICINE, 2020, 19 (04) : 446 - 446
  • [6] Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy
    Wang, Feng
    Zhang, Jian
    Fang, Wei
    Zhao, Shi-Hua
    Lu, Min-Jie
    He, Zuo-Xiang
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (10) : 1611 - 1621
  • [7] Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy
    Feng Wang
    Jian Zhang
    Wei Fang
    Shi-Hua Zhao
    Min-Jie Lu
    Zuo-Xiang He
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 1611 - 1621
  • [8] Measuring the Left Ventricular Ejection Fraction using Geometric Features
    Lagopoulos, Athanasios
    Hristu-Varsakelis, Dimitrios
    2022 IEEE 35TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2022, : 1 - 6
  • [9] A dynamic heart model for the mathematical cardiac torso (MCAT) phantom to represent the invariant total heart volume
    Pretorius, PH
    King, MA
    Tsui, BMW
    LaCroix, K
    Xia, WS
    PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1998, 1998, 3337 : 153 - 163
  • [10] Evaluation of right ventricular volume and ejection fraction by gated 18F-FDG PET in patients with pulmonary hypertension: Comparison with cardiac MRI and CT
    Wang, Lei
    Zhang, Yan
    Yan, Chaowu
    He, Jianguo
    Xiong, Changming
    Zhao, Shihua
    Fang, Wei
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (02) : 242 - 252