Evaluation of deep inspiration breath-hold lung treatment plans with Monte Carlo dose calculation

被引:36
|
作者
Yorke, ED
Wang, L
Rosenzweig, KE
Mah, D
Paoli, JB
Chui, CS
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10021 USA
[3] Univ Penn, Sch Med, Dept Radiat Oncol, Philadelphia, PA 19104 USA
[4] Fox Chase Canc Ctr, Dept Radiat Oncol, Philadelphia, PA 19111 USA
[5] CHU Timone, Serv Radiat Oncol, Marseille, France
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 53卷 / 04期
关键词
dose calculation; treatment planning; Monte Carlo; tissue inhomogeneity; breath hold; lung cancer; dose distribution;
D O I
10.1016/S0360-3016(02)02778-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate dosimetry of deep inspiration breath-hold (DIBH) relative to free breathing (FB) for three-dimensional conformal radiation therapy of lung cancer with 6-MV photons and Monte Carlo (MC) dose calculations. Methods and Materials: Static three-dimensional conformal radiation therapy, 6-MV plans, based on DIBH and FB CT images for five non-small-cell lung cancer patients, were generated on a clinical treatment planning system with equivalent path length tissue inhomogeneity correction. Margins of gross to planning target volume were not reduced for DIBH plans. Cord and lung toxicity determined the maximum treatment dose for each plan. Dose distributions were recalculated for the same beams with an MC dose calculation algorithm and electron density distributions derived from the CT images. Results: MC calculations showed decreased target coverage relative to treatment-planning system predictions. Lateral disequilibrium caused more degradation of target coverage for DIBH than for FB (approximately 4% worse than expected for FB vs. 8% for DIBH). However, with DIBH higher treatment doses could be delivered without violating normal tissue constraints, resulting in higher total doses to gross target volume and to >99% of planning target volume. Conclusions: If DIBH enables prescription dose increases exceeding 10%, MC calculations indicate that, despite lateral disequilibrium, higher doses will be delivered to medium-to-large, partly mediastinal gross target volumes, providing that 6-MV photons are used and margins are not reduced. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1058 / 1070
页数:13
相关论文
共 50 条
  • [31] Fast Monte Carlo dose calculation based on deep learning
    Fu, Jiaqi
    Bai, Jingfeng
    Liu, Yanfang
    Ni, Cheng
    2020 13TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2020), 2020, : 721 - 726
  • [32] Commissioning a fast Monte Carlo dose calculation algorithm for lung cancer treatment planning
    Craig, Jeff
    Oliver, Mike
    Gladwish, Adam
    Mulligan, Matt
    Chen, Jeff
    Wong, Eugene
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (02): : 83 - 97
  • [33] A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation
    Zhao, Yanqun
    Qi, Guohai
    Yin, Gang
    Wang, Xianliang
    Wang, Pei
    Li, Jian
    Xiao, Mingyong
    Li, Jie
    Kang, Shengwei
    Liao, Xiongfei
    RADIATION ONCOLOGY, 2014, 9
  • [34] A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation
    Yanqun Zhao
    Guohai Qi
    Gang Yin
    Xianliang Wang
    Pei Wang
    Jian Li
    Mingyong Xiao
    Jie Li
    Shengwei Kang
    Xiongfei Liao
    Radiation Oncology, 9
  • [35] Deep-inspiration breath-hold PET/CT:: Clinical findings with a new technique for detection and characterization of thoracic lesions
    Meirelles, Gustavo S. P.
    Erdi, Yusuf Emre
    Nehmeh, Sadek A.
    Squire, Olivia D.
    Larson, Steven M.
    Humm, John L.
    Schoder, Heiko
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) : 712 - 719
  • [36] Prospective phase II trial of image-guided radiotherapy in Hodgkin lymphoma: Benefit of deep inspiration breath-hold
    Petersen, Peter M.
    Aznar, Marianne C.
    Berthelsen, Anne K.
    Loft, Annika
    Schut, Deborah A.
    Maraldo, Maja
    Josipovic, Mirjana
    Klausen, Thomas L.
    Andersen, Flemming L.
    Specht, Lena
    ACTA ONCOLOGICA, 2015, 54 (01) : 60 - 66
  • [37] Deep-Inspiration Breath-Hold Intensity Modulated Radiation Therapy to the Mediastinum for Lymphoma Patients: Setup Uncertainties and Margins
    Aristophanous, Michalis
    Chi, Pai-Chun M.
    Kao, Jeremy
    Williamson, Ryan
    Tung, Sam
    Andraos, Therese
    Milgrom, Sarah A.
    Pinnix, Chelsea C.
    Dabaja, Bouthaina S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (01): : 254 - 262
  • [38] Application of tangent-arc technology for deep inspiration breath-hold radiotherapy in left-sided breast cancer
    Li, Yucheng
    Zhan, Wenming
    Jia, Yongshi
    Xiong, Hanchu
    Lin, Baihua
    Li, Qiang
    Liu, Huaxin
    Qiu, Lingyun
    Zhang, Yinghao
    Ding, Jieni
    Fu, Chao
    Chen, Weijun
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [39] Dosimetric effects of intrafractional isocenter variation during deep inspiration breath-hold for breast cancer patients using surface-guided radiotherapy
    Kugele, Malin
    Edvardsson, Anneli
    Berg, Lovisa
    Alkner, Sara
    Ljus, Carina Andersson
    Ceberg, Sofie
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 25 - 38
  • [40] Reproducibility and stability of spirometer-guided deep inspiration breath-hold in left-breast treatments using an optical surface monitoring system
    Cilla, Savino
    Romano, Carmela
    Craus, Maurizio
    Viola, Pietro
    Macchia, Gabriella
    Boccardi, Mariangela
    De Vivo, Livia P.
    Buwenge, Milly
    Morganti, Alessio G.
    Deodato, Francesco
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (06):