Stability Enhancement in Distribution Systems with DFIG-Based Wind Turbine by Use of SFCL

被引:0
作者
Zhao, Yu [1 ]
Krause, Olav [1 ]
Saha, Tapan K. [1 ]
Li, Yong [2 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld, Australia
[2] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
来源
2013 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC) | 2013年
关键词
distribution system; doubly-fed induction generator (DFIG); stability; superconducting fault current limiter (SFCL); fault current limitation; voltage sags; electrical torque;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A significant amount of renewable energy based power is being integrated at the distribution or sub-transmission level worldwide, known as Distributed Generation (DG). And the Doubly-Fed Induction Generator (DFIG) based wind turbine is one of the utmost important branches of DG development. However, the DFIGs suffer from high sensitivity from system disturbance that they cannot keep connection with utility under severe faults. This paper proposed to apply a superconducting fault current limiter (SFCL) in a distribution network with DFIG to limit the short-circuit currents so as to improve system stability. This presented study is aiming at providing deeper insight into the implication of the two main SFCL deployment strategies, DG-side and feeder deployment. The study is carried out using PSCAD/EMTDC with special focuses on stator currents, voltage sags, active and reactive power of the DFIG-based wind turbine effected by the short-circuit faults and the SFCL.
引用
收藏
页数:6
相关论文
共 13 条
[1]  
[Anonymous], 2003, IEEE STANDARD 1547
[2]   Future development of the electricity systems with distributed generation [J].
Bayod-Rujula, Angel A. .
ENERGY, 2009, 34 (03) :377-383
[3]   Modeling and Control of a Doubly-Fed Induction Generator (DFIG) Wind Power Generation System for Real-time Simulations [J].
Byeon, Gilsung ;
Park, In Kwon ;
Jang, Gilsoo .
JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2010, 5 (01) :61-69
[4]   Analysis of Transient Stability Enhancement of LV-Connected Induction Microgenerators by Using Resistive-Type Fault Current Limiters [J].
Emhemed, Abdullah Swissi ;
Tumilty, Ryan M. ;
Singh, Nand K. ;
Burt, Graeme M. ;
McDonald, James R. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2010, 25 (02) :885-893
[5]   Doubly fed induction generator model for transient stability analysis [J].
Ledesma, P ;
Usaola, J .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :388-397
[6]   Assessment of the Impact of SFCL on Voltage Sags in Power Distribution System [J].
Moon, Jong-Fil ;
Lim, Sung-Hun ;
Kim, Jae-Chul ;
Yun, Sang-Yun .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) :2161-2164
[7]  
Moon W. S., IEEE T APPL SUPERCON
[8]   Doubly fed induction generator systems for wind turbines [J].
Müller, S ;
Deicke, M ;
De Doncker, RW .
IEEE INDUSTRY APPLICATIONS MAGAZINE, 2002, 8 (03) :26-33
[9]   The Effect of SFCL on Electric Power Grid With Wind-Turbine Generation System [J].
Park, Woo-Jae ;
Sung, Byung Chul ;
Park, Jung-Wook .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) :1177-1181
[10]  
Seyoum D., 2004, AUSTR U POW ENG C AU, P137