Quality assessment of pacemaker implantations in Denmark

被引:42
作者
Moller, M [1 ]
Arnsbo, P
Asklund, M
Christensen, PD
Gadsboll, N
Svendsen, JH
Klarholt, E
Kleist, KE
Mortensen, PT
Pietersen, A
Simonsen, EH
Thomsen, PEB
Vesterlund, T
Wiggers, P
机构
[1] Odense Univ Hosp, Dept Cardiol, Danish Pacemaker Register, DK-5000 Odense C, Denmark
[2] Kolding Sygehus, Kolding, Denmark
[3] Viborg Sygehus, Viborg, Denmark
[4] Bispebjerg Hosp, DK-2400 Copenhagen, Denmark
[5] Rigshosp, DK-2100 Copenhagen, Denmark
[6] Herning Centralsygehus, Herning, Denmark
[7] Dronning Ingrids Hosp, Nuuk, Denmark
[8] Skejby Sygehus, DK-8200 Aarhus, Denmark
[9] Hillerod Sygehus, Hillerod, Denmark
[10] Odense Univ Hosp, DK-5000 Odense, Denmark
[11] Amtssygehuset Gentofte, Hellerup, Denmark
[12] Aalborg Hosp, Aalborg, Denmark
[13] Haderslev Sygehus, Haderslev, Denmark
来源
EUROPACE | 2002年 / 4卷 / 02期
关键词
pacemaker; pacemaker leads; complications; quality standards;
D O I
10.1053/eupc.2002.0234
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Quality assessment of therapeutic procedures is essential to insure a cost-effective health care system. Pacemaker implantation is a common procedure with more than 500 000 implantations world-wide per year, but the general complication rate is not well described. We studied procedure related complications for all implantations performed in an entire nation over a 3-year period. Methods and Results A prospective study of complications related to 99% of the 5648 primary pacemaker implantations performed in the 12 Danish pacemaker centres in 1997-1999 was carried out. Overall 76% of the patients received a physiological pacemaker system and 91% received the optimal pacing mode according to international guidelines. Perioperative complications requiring reoperation were: haematoma 0.3%, atrial lead related 1.9%, ventricular lead related 1.7%. Late complications requiring reoperation were: infection 0.2%, atrial lead related 1.3%, ventricular lead related 1.2%. The complication rate decreased over the study period, but overall the complication rate was higher than expected and showed considerable variation between centres. Conclusions Our results demonstrate that sensitive data such as complications related to pacemaker implantations can be collected on a national basis. We suggest that a reoperation rate higher than 3% for atrial as well as ventricular pacing electrodes in the individual implanting centre should cause the centre to evaluate carefully the procedure as well as the performance of the individual implanter. (C) 2002 Published by Elsevier Science Ltd on behalf of The European Society of Cardiology.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 21 条
  • [1] AGGARWAL RK, 1995, BRIT HEART J, V73, P571
  • [2] Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome
    Andersen, HR
    Nielsen, JC
    Thomsen, PEB
    Thuesen, L
    Mortensen, PT
    Vesterlund, T
    Pedersen, AK
    [J]. LANCET, 1997, 350 (9086) : 1210 - 1216
  • [3] Updated appraisal of pacing lead performance from the Danish Pacemaker Register: The reliability of bipolar pacing leads has improved
    Arnsbo, P
    Moller, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (09): : 1401 - 1406
  • [4] Quality of health care .2. Measuring quality of care
    Brook, RH
    McGlynn, EA
    Cleary, PD
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (13) : 966 - 970
  • [5] EARLY COMPLICATIONS AFTER DUAL-CHAMBER VERSUS SINGLE CHAMBER PACEMAKER IMPLANTATION
    CHAUHAN, A
    GRACE, AA
    NEWELL, SA
    STONE, DL
    SHAPIRO, LM
    SCHOFIELD, PM
    PETCH, MC
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 2012 - 2015
  • [6] CLARKE M, 1991, BRIT HEART J, V66, P185
  • [7] Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes
    Connolly, SJ
    Kerr, CR
    Gent, M
    Roberts, RS
    Yusuf, S
    Gillis, AM
    Sami, MH
    Talajic, M
    Tang, ASL
    Klein, GJ
    Lau, C
    Newman, DM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (19) : 1385 - 1391
  • [8] Permanent pacemaker insertion in a district general hospital: indications, patient characteristics, and complications
    Eltrafi, A
    Currie, P
    Silas, JH
    [J]. POSTGRADUATE MEDICAL JOURNAL, 2000, 76 (896) : 337 - 339
  • [9] Gregoratos G, 1998, J AM COLL CARDIOL, V31, P1175
  • [10] Kappenberger L, 1997, EUR HEART J, V18, P1249