pQuant Improves Quantitation by Keeping out Interfering Signals and Evaluating the Accuracy of Calculated Ratios

被引:69
作者
Liu, Chao [1 ,2 ]
Song, Chun-Qing [3 ]
Yuan, Zuo-Fei [1 ]
Fu, Yan [1 ]
Chi, Hao [1 ,2 ]
Wang, Le-Heng [1 ]
Fan, Sheng-Bo [1 ,2 ]
Zhang, Kun [1 ,2 ]
Zeng, Wen-Feng [1 ,2 ]
He, Si-Min [1 ,2 ]
Dong, Meng-Qiu [3 ]
Sun, Rui-Xiang [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Comp Technol, Key Lab Intelligent Informat Proc, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Natl Inst Biol Sci, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
FALSE DISCOVERY RATE; PROTEIN IDENTIFICATION; MASS-SPECTROMETRY; PEPTIDE IDENTIFICATION; PROTEOMICS; REGRESSION; QUANTIFICATION; EXPRESSION; SPECTRA; PFIND;
D O I
10.1021/ac404246w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In relative protein abundance determination from peptide intensities recorded in full mass scans, a major complication that affects quantitation accuracy is signal interference from coeluting ions of similar m/z values. Here, we present pQuant, a quantitation software tool that solves this problem. pQuant detects interference signals, identifies for each peptide a pair of least interfered isotopic chromatograms: one for the light and one for the heavy isotope-labeled peptide. On the basis of these isotopic pairs, pQuant calculates the relative heavy/light peptide ratios along with their 99.75% confidence intervals (CIs). From the peptides ratios and their CIs, pQuant estimates the protein ratios and associated CIs by kernel density estimation. We tested pQuant, Census and MaxQuant on data sets obtained from mixtures (at varying mixing ratios from 10:1 to 1:10) of light- and heavy-SILAC labeled HeLa cells or N-14- and N-15-labeled Escherichia coli cells. pQuant quantitated more peptides with better accuracy than Census and MaxQuant in all 14 data sets. On the SILAC data sets, the nonquantified "NaN" (not a number) ratios generated by Census, MaxQuant, and pQuant accounted for 2.5-10.7%, 1.8-2.7%, and 0.01-0.5% of all ratios, respectively. On the N-14/N-15 data sets, which cannot be quantified by MaxQuant, Census and pQuant produced 0.9-10.0% and 0.3-2.9% NaN ratios, respectively. Excluding these NaN results, the standard deviations of the numerical ratios calculated by Census or MaxQuant are 30-100% larger than those by pQuant. These results show that pQuant outperforms Census and MaxQuant in SILAC and N-15-based quantitation.
引用
收藏
页码:5286 / 5294
页数:9
相关论文
共 51 条
  • [1] Quantitative mass spectrometry in proteomics: a critical review
    Bantscheff, Marcus
    Schirle, Markus
    Sweetman, Gavain
    Rick, Jens
    Kuster, Bernhard
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (04) : 1017 - 1031
  • [2] Bantscheff M, 2012, ANAL BIOANAL CHEM, V404, P939, DOI 10.1007/s00216-012-6203-4
  • [3] CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING
    BENJAMINI, Y
    HOCHBERG, Y
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) : 289 - 300
  • [4] BONATE PL, 1992, LC GC-MAG SEP SCI, V10, P378
  • [5] Current challenges in software solutions for mass spectrometry-based quantitative proteomics
    Cappadona, Salvatore
    Baker, Peter R.
    Cutillas, Pedro R.
    Heck, Albert J. R.
    van Breukelen, Bas
    [J]. AMINO ACIDS, 2012, 43 (03) : 1087 - 1108
  • [6] Methods for combining peptide intensities to estimate relative protein abundance
    Carrillo, Brian
    Yanofsky, Corey
    Laboissiere, Sylvie
    Nadon, Robert
    Kearney, Robert E.
    [J]. BIOINFORMATICS, 2010, 26 (01) : 98 - 103
  • [7] LEVERAGE AND REGRESSION THROUGH THE ORIGIN
    CASELLA, G
    [J]. AMERICAN STATISTICIAN, 1983, 37 (02) : 147 - 152
  • [8] CHAMBERS RL, 1986, BIOMETRIKA, V73, P597
  • [9] Colaert N, 2011, METHODS MOL BIOL, V753, P373, DOI 10.1007/978-1-61779-148-2_25
  • [10] CORNBLEET PJ, 1979, CLIN CHEM, V25, P432