Relationship among Corneal Biomechanics, Refractive Error, and Axial Length

被引:64
作者
Bueno-Gimeno, Inmaculada [1 ]
Espana-Gregori, Enrique [2 ,3 ]
Gene-Sampedro, Andres [1 ]
Lanzagorta-Aresti, Aitor [4 ]
Pinero-Llorens, David P. [5 ,6 ]
机构
[1] Univ Valencia, Dept Opt, E-46100 Burjassot, Valencia, Spain
[2] Univ Valencia, Dept Surg, E-46100 Burjassot, Valencia, Spain
[3] Univ Valencia, Univ Hosp La Fe, E-46100 Burjassot, Valencia, Spain
[4] Fdn Oftalmol Mediterraneo, Valencia, Spain
[5] FUNCAVIS, Fdn Visual Qual, Alicante, Spain
[6] Univ Alicante, Dept Opt Pharmacol & Anat, E-03080 Alicante, Spain
关键词
corneal biomechanical properties; refractive error; children; age; ocular parameters; OCULAR RESPONSE ANALYZER; INTRAOCULAR-PRESSURE; ANTERIOR SEGMENT; REPEATABILITY; CHILDREN; REPRODUCIBILITY; HYSTERESIS; PARAMETERS; IOLMASTER; GROWTH;
D O I
10.1097/OPX.0000000000000231
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickness (CCT) and anterior chamber depth were measured by anterior segment optical coherence tomography (Visante). Results Mean (SD) CH and CRF were 12.12 (+/- 1.71) and 12.30 (+/- 1.89) mm Hg, respectively. Mean (+/- SD) CCT was 542.68 (+/- 37.20) m and mean (+/- SD) spherical equivalent was +0.14 (+/- 3.41) diopters. A positive correlation was found between CH and CRF (p < 0.001), and both correlated as well with CCT (p < 0.0001). Corneal resistance factor was found to decrease with increasing age (p = 0.01). Lower levels of CH were associated with longer AL and more myopia (p < 0.001 and p = 0.001, respectively). Higher values of CH were associated with increasing hyperopia. Significant differences in CH were found between emmetropic and myopic groups (p < 0.001) and between myopic and hyperopic groups (p = 0.011). There were also significant differences in CRF between emmetropic and myopic groups (p = 0.02). Multiple linear regression analysis showed that lower CH and CRF significantly associated with thinner CCT, longer AL, and flatter corneal curvature. Conclusions The Ocular Response Analyzer corneal biomechanical properties seem to be compromised in myopia from an early age, especially in high myopia.
引用
收藏
页码:507 / 513
页数:7
相关论文
共 39 条
[1]   Prevalence of refractive errors among pre-school children at King Abdulaziz Medical City, Riyadh, Saudi Arabia [J].
Al-Rowaily, Mohammad A. .
SAUDI JOURNAL OF OPHTHALMOLOGY, 2010, 24 (02) :45-48
[2]   Shape of the retinal surface in emmetropia and myopia [J].
Atchison, DA ;
Pritchard, N ;
Schmid, KL ;
Scott, DH ;
Jones, CE ;
Pope, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (08) :2698-2707
[3]   Static and dynamic analysis of the anterior segment with optical coherence tomography [J].
Baikoff, G ;
Lutun, E ;
Ferraz, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09) :1843-1850
[4]   Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of Intraocular pressure [J].
Broman, Aimee Teo ;
Congdon, Nathan G. ;
Bandeen-Roche, Karen ;
Quigley, Harry A. .
JOURNAL OF GLAUCOMA, 2007, 16 (07) :581-588
[5]   The heritability of corneal hysteresis and ocular pulse amplitude - A twin study [J].
Carbonaro, Francis ;
Andrew, Toby ;
Mackey, David A. ;
Spector, Tim D. ;
Hammond, Chris J. .
OPHTHALMOLOGY, 2008, 115 (09) :1545-1549
[6]   Repeatability of IOLMaster biometry in children [J].
Carkeet, A ;
Saw, SM ;
Gazzard, G ;
Tang, W ;
Tan, DTH .
OPTOMETRY AND VISION SCIENCE, 2004, 81 (11) :829-834
[7]   Assessment of corneal biomechanical properties and intraocular pressure with the Ocular Response Analyzer in childhood myopia [J].
Chang, Pei-Yao ;
Chang, Shu-Wen ;
Wang, Jiun-Yi .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (07) :877-881
[8]   The cornea in young myopic adults [J].
Chang, SW ;
Tsai, IL ;
Hu, FR ;
Lin, LLK ;
Shih, YF .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (08) :916-920
[9]  
Edwards MH, 1996, OPHTHAL PHYSL OPT, V16, P243, DOI 10.1016/0275-5408(95)00064-X
[10]   INTRAOCULAR-PRESSURE IN A SELECTED SAMPLE OF MYOPIC AND NONMYOPIC CHINESE CHILDREN [J].
EDWARDS, MH ;
BROWN, B .
OPTOMETRY AND VISION SCIENCE, 1993, 70 (01) :15-17