Optical absorption and scattering properties of bulk porcine muscle phantoms from interstitial radiance measurements in 650-900 nm range

被引:10
作者
Grabtchak, Serge [1 ,2 ,3 ]
Montgomery, Logan G. [1 ]
Whelan, William M. [1 ,4 ]
机构
[1] Univ Prince Edward Isl, Dept Phys, Charlottetown, PE C1A 4P3, Canada
[2] Dalhousie Univ, Dept Elect & Comp Engn, Halifax, NS B3H 3J5, Canada
[3] Dalhousie Univ, Dept Phys, Halifax, NS B3H 3J5, Canada
[4] Atlantic Vet Coll, Charlottetown, PE C1A 4P3, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
porcine muscle; radiance spectroscopy; optical properties; absorption; scattering; tissue oxygenation; NEAR-INFRARED SPECTROSCOPY; TISSUE OXYGENATION; TUMOR-TISSUE; BLOOD-FLOW; IN-VITRO; MODEL; REFLECTANCE; MITOCHONDRIA; MEAT; PIG;
D O I
10.1088/0031-9155/59/10/2431
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We demonstrated the application of relative radiance-based continuous wave (cw) measurements for recovering absorption and scattering properties (the effective attenuation coefficient, the diffusion coefficient, the absorption coefficient and the reduced scattering coefficient) of bulk porcine muscle phantoms in the 650-900 nm spectral range. Both the side-firing fiber (the detector) and the fiber with a spherical diffuser at the end (the source) were inserted interstitially at predetermined locations in the phantom. The porcine phantoms were prostate- shaped with similar to 4 cm in diameter and similar to 3 cm thickness and made from porcine loin or tenderloin muscles. The described method was previously validated using the diffusion approximation on simulated and experimental radiance data obtained for homogenous Intralipid-1% liquid phantom. The approach required performing measurements in two locations in the tissue with different distances to the source. Measurements were performed on 21 porcine phantoms. Spectral dependences of the effective attenuation and absorption coefficients for the loin phantom deviated from corresponding dependences for the tenderloin phantom for wavelengths < 750 nm. The diffusion constant and the reduced scattering coefficient were very close for both phantom types. To quantify chromophore presence, the plot for the absorption coefficient was matched with a synthetic absorption spectrum constructed from deoxyhemoglobin, oxyhemoglobin and water. The closest match for the porcine loin spectrum was obtained with the following concentrations:
引用
收藏
页码:2431 / 2444
页数:14
相关论文
共 69 条
[51]   The porcine lung as a potential model for cystic fibrosis [J].
Rogers, Christopher S. ;
Abraham, William M. ;
Brogden, Kim A. ;
Engelhardt, John F. ;
Fisher, John T. ;
McCray, Paul B., Jr. ;
McLennan, Geoffrey ;
Meyerholz, David K. ;
Namati, Eman ;
Ostedgaard, Lynda S. ;
Prather, Randall S. ;
Sabater, Juan R. ;
Stoltz, David Anthony ;
Zabner, Joseph ;
Welsh, Michael J. .
AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2008, 295 (02) :L240-L263
[52]   The effect of preparation technique on the optical parameters of biological tissue [J].
Roggan, A ;
Schädel, D ;
Netz, U ;
Ritz, JP ;
Germer, CT ;
Müller, G .
APPLIED PHYSICS B-LASERS AND OPTICS, 1999, 69 (5-6) :445-453
[53]   In vivo near-infrared spectroscopy [J].
Rolfe, P .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2000, 2 :715-754
[54]   A review of in-vivo optical properties of human tissues and its impact on PDT [J].
Sandell, Julia L. ;
Zhu, Timothy C. .
JOURNAL OF BIOPHOTONICS, 2011, 4 (11-12) :773-787
[55]   Optical spectroscopic method for in vivo measurement of cardiac myoglobin oxygen saturation [J].
Schenkman, KA ;
Marble, DR ;
Burns, DH ;
Feigl, EO .
APPLIED SPECTROSCOPY, 1999, 53 (03) :332-338
[56]  
Segelstein D., 1981, PHD THESIS
[57]  
Shapiro N I, 2011, CRIT CARE, V15, P10
[58]   In vivo optical/near-infrared spectroscopy and imaging of metalloproteins [J].
Shaw, RA ;
Mansfield, JR ;
Kupriyanov, VV ;
Mantsch, HH .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2000, 79 (1-4) :285-293
[59]   The pig as an experimental animal model of percutaneous permeation in man: Qualitative and quantitative observations - An overview [J].
Simon, GA ;
Maibach, HI .
SKIN PHARMACOLOGY AND APPLIED SKIN PHYSIOLOGY, 2000, 13 (05) :229-234
[60]   Effects of acute hypoxia on cerebral and muscle oxygenation during incremental exercise [J].
Subudhi, Andrew W. ;
Dimmen, Andrew C. ;
Roach, Robert C. .