Radiologic Examinations in Human Temporal Bone Specimens Using Digital Volume Tomography and High-Resolution Computed Tomography After Implantation of Middle Ear Prosthesis and Cochlear Implant Electrode Array

被引:1
作者
Bremke, Martin [1 ]
Lueers, Jan-Christoffer [1 ]
Stenner, Markus [1 ]
Bovenschulte, Henning [2 ]
Dorn, Franziska [2 ]
Unkel, Claus [3 ]
Hoellering, Jens [3 ]
Beutner, Dirk [1 ]
机构
[1] Univ Cologne, Dept Otorhinolaryngol Head & Neck Surg, D-50937 Cologne, Germany
[2] Univ Cologne, Dept Radiol, D-50937 Cologne, Germany
[3] Ctr 3D Diagnost, Arnsberg, Germany
关键词
Cochlear implant; Cone beam tomography; Digital volume tomography; High-resolution computed tomography; Middle ear prosthesis; Radiology of the temporal bone; Rotational tomography; ROTATIONAL TOMOGRAPHY; VIRTUAL ENDOSCOPY; OSSICULAR CHAIN; QUALITY-CONTROL; CT; SURGERY;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction: Adequate imaging of the middle ear and its surrounding structures is an essential preoperative part in ear surgery. In the past, the main disadvantage of computed tomography (CT) scanners was the decreased diagnostic quality due to metallic artifacts. Furthermore, these scanners showed mostly an inferior image quality compared to digital volume tomography (DVT) in the temporal bone. It was the aim of this experimental study to compare the image quality of a state-of-the-art dual-source 2 x 128-slice CT scanner to DVT in temporal bone specimen. Materials and Methods: Metallic prosthesis (PORP, TORP, stapes piston, cochlear implant electrode array) and an autologous incus were implanted in temporal bone specimen to analyze the diagnostic quality concerning the characterization of anatomic structures. Three further temporal bones were scanned without any preparation. Independently, 2 otologists and 2 radiologists scored the image quality of defined anatomic structures, using a range from 4 (excellent) to 0 (no diagnostic value). Results: The general score for DVT was 2.67, whereas CT reached a score of 2.76. The diagnostic value for hard contrast objects was 3.0 for DVT and 2.9 for CT, whereas the score for soft tissue was 1.1 for DVT and 2.3 for CT. Almost no quality reduction of the display of anatomic structures caused by metallic artifacts could be detected in both diagnostic modalities. Discussion: Both DVT and high-resolution CT allow good overall image quality in temporal bones, with discrete advantages for digital volume tomographic scans in terms of the image quality of hard contrast objects like bony structures or metallic implants.
引用
收藏
页码:1321 / 1328
页数:8
相关论文
共 20 条
[1]  
[Anonymous], ACTA OTOLARYNGOL
[2]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[3]   Quality control after cochlear implant surgery by means of rotational tomography [J].
Aschendorff, A ;
Kubalek, T ;
Turowski, B ;
Zanella, T ;
Hochmuth, T ;
Schumacher, T ;
Klenzner, T ;
Laszig, R .
OTOLOGY & NEUROTOLOGY, 2005, 26 (01) :34-37
[4]   Quality control after insertion of the nucleus contour and contour advance electrode in adults [J].
Aschendorff, Antje ;
Kromeier, Jan ;
Klenzner, Thomas ;
Laszig, Roland .
EAR AND HEARING, 2007, 28 (02) :75S-79S
[5]   Digital volume tomography in ENT medicine [J].
Bremke, M. ;
Leppek, R. ;
Werner, J. A. .
HNO, 2010, 58 (08) :823-830
[6]  
Bremke M, 2009, RHINOLOGY, V47, P126
[7]  
Dahmani-Causse M, 2011, EUR ANN OTOLARYNGOL, V128, P272
[8]   Value of digital volume tomography in patients with conductive hearing loss [J].
Dalchow, CV ;
Weber, AL ;
Bien, S ;
Yanagihara, N ;
Werner, JA .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2006, 263 (02) :92-99
[9]   Digital volume tomography: Radiologic examinations of the temporal bone [J].
Dalchow, CV ;
Weber, AL ;
Yanagihara, N ;
Bien, S ;
Werner, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) :416-423
[10]   3-DIMENSIONAL CT-IMAGING OF THE OSSICULAR CHAIN [J].
HERMANS, R ;
FEENSTRA, L ;
MARCHAL, G ;
BAERT, AL .
CLINICAL OTOLARYNGOLOGY, 1995, 20 (05) :475-478