Medical phase contrast x-ray imaging: current status and future prospects

被引:307
作者
Lewis, RA [1 ]
机构
[1] Monash Univ, Monash Ctr Synchrotron Sci, Clayton, Vic 3800, Australia
[2] Monash Univ, Sch Phys & Mat Engn, Clayton, Vic 3800, Australia
关键词
D O I
10.1088/0031-9155/49/16/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The exploitation of phase contrast appears to offer the tantalising possibility of creating the biggest change in medical x-ray imaging since the invention of computed tomography. A considerable number of experiments performed by researchers across four continents have produced some extraordinary images. These images have demonstrated greatly enhanced contrast over conventional methods revealing soft tissue discrimination at micron scale resolutions. Contrast improvements can be achieved at doses rather less than those required by conventional x-ray imaging. The use of synchrotrons has revealed the possibilities offered by these techniques but unfortunately the application of these ideas in a clinical context requires that technology be pushed to its limits in a number of areas including x-ray sources, optics and detectors. The current state of the art is reviewed.
引用
收藏
页码:3573 / 3583
页数:11
相关论文
共 29 条
[1]  
ALSNIELSEN J, 2001, ELEMENTS MODER XRAY
[2]  
[Anonymous], TABLES XRAY MASS ATT, DOI DOI 10.18434/T4D01F
[3]   Mammography with synchrotron radiation: Phase-detection techniques [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Fabrizioli, M ;
Longo, R ;
Menk, RH ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Ratti, M ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
RADIOLOGY, 2000, 215 (01) :286-293
[4]  
Chantler C. T., 2003, XRAY FORM FACTOR ATT
[5]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[6]   Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method [J].
Dilmanian, FA ;
Zhong, Z ;
Ren, B ;
Wu, XY ;
Chapman, LD ;
Orion, I ;
Thomlinson, WC .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :933-946
[7]   Quantification of the effect of kVp on edge-enhancement index in phase-contrast radiography [J].
Donnelly, EF ;
Price, RR .
MEDICAL PHYSICS, 2002, 29 (06) :999-1002
[8]   Imaging lobular breast carcinoma:: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology [J].
Fiedler, S ;
Bravin, A ;
Keyriläinen, J ;
Fernández, M ;
Suortti, P ;
Thomlinson, W ;
Tenhunen, M ;
Virkkunen, P ;
Karjalainen-Lindsberg, ML .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02) :175-188
[9]   Phase contrast digital mammography using molybdenum X-ray: Clinical implications in detectability improvement [J].
Freedman, MT ;
Lo, SCB ;
Honda, C ;
Makariou, E ;
Sisney, G ;
Pien, E ;
Ohara, H ;
Ishisaka, A ;
Shimada, F .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :533-540
[10]   Application of absorption and refraction matching techniques for diffraction enhanced imaging [J].
Hasnah, M ;
Oltulu, O ;
Zhong, Z ;
Chapman, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03) :1657-1659